1 / 46

ELIS PLZEŇ a. s. PRODUCTS

ELIS PLZEŇ a. s. PRODUCTS. ULTRASONIC WATER AND FLOW METERS. Intended for measurement of conductive and non- conductive clean liquids as water, demineralized water, fuel, oil, etc.

Download Presentation

ELIS PLZEŇ a. s. PRODUCTS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic ELIS PLZEŇ a. s. PRODUCTS ULTRASONIC WATER ANDFLOW METERS

  2. Intended for measurement of conductive and non- conductive clean liquids as water, demineralized water, fuel, oil, etc. • Principal: transit time (measurement of time of flying ultrasonic beam from one to second transductorin direction of flow and in opposite direction of flow). • The flow rate is calculated from difference of time. • Flow meters are produced in single and dual beam version. • They don’t have any moving parts • They have min. pressure loses ULTRASONIC FLOW METERS ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

  3. Produced categories of ultrasonic flow meters: • Battery supplied single or dual beam: • FLOMIC FL5024, FL5044 (DN32 to DN200) • FLOMIC FL5034, FL5054 (DN32 to DN300) • FLOMIC FL3085(DN200 to DN1200) • FLOMIC FL3005 (DN200 to DN2000) for directassembly into piping ULTRASONIC FLOW METERS ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

  4. Main powered single or dual beam: • SONOELIS SE404X, SE406X(DN32 to DN300) • SONOELIS SE401X, SE402X(DN200 to DN1200) • SONOELIS SE804X, SE806X(DN200 to DN1200)for direct assembly in to piping ULTRASONIC FLOW METERS ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

  5. BATTERY POWERED ULTRASONIC WATER METERS FLOMIC FL5024 (single beam) FLOMIC FL5044 (dual beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

  6. BATTERY POWERED ULTRASONIC WATER METERS FLOMIC FL5024 (single beam) FLOMIC FL5044 (dual beam) • Certified according to MID (European metrology certificate) and OIML R49 • Designed in observance of standard EN14154 • Intended for measurement of clean water and substitution ofmechanical water meters WOLTMAN type • Intended for diagnostic of general condition of water network and water leakages in piping • They can measure instantaneous flow rate in both direction, consumption of water, pressure • They don’t have any moving parts • They have very low pressure loses ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

  7. BATTERY POWERED ULTRASONIC WATER METERS FLOMIC FL5024 (single beam), FLOMIC FL5044 (dual beam) • Nominal diameter:DN32 to DN200 (single beam), DN65 to DN200 (dual beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

  8. BATTERY POWERED ULTRASONIC WATER METERS FLOMIC FL5024 (single beam) FLOMIC FL5044 (dual beam) • Material of sensor: casting from cast iron • Connection: flanges (EN, ANSI, JIS) • Water pressure class: MAP16 • Temperature class: T50 • Flow-profile sensitivity class:U5 (FL5044), U10 (FL5024) – in front of meter D3 (FL5044), D5 (FL5024) – behind meter • Pressure loss class: ∆P10 • Climatic and mechanical class: B • Electromagnetic environment: E1, E2 • Display unit: single-line 8 character LC display • Flow rate sampling period: 1 sec • Protection class: IP68 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

  9. BATTERY POWERED ULTRASONIC WATER METERS FLOMIC FL5024 (single beam) FLOMIC FL5044 (dual beam) • Power supply: Li battery 3,6 V/19Ah – live time 8 years • Output: passive pulse output (U= 3 to 30V, I = 0,002 to 10mA, timp = 30ms) passive currentoutput 4 to 20mA (U = 10 to 24 V) • Optional equipment: bi-directional measurement (± passive pulse output) passive current output 4 to 20mA in combination of electrical contact for flow direction USB, RS232 or RS232 + USB converter GSM module FLODAT FD1.00 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

  10. BATTERY POWERED ULTRASONIC WATER METERS FLOMIC FL5024 (single beam) FLOMIC FL5044 (dual beam) • BASIC DIMENSIONS and WEIGHT ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

  11. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL5034 (single beam) FLOMIC FL5054 (dual beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 11

  12. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL5034 (single beam) FLOMIC FL5054 (dual beam) • Intended for measurement of clean water • They can measure instantaneous flow rate in both direction, consumption of water, pressure • They don’t have any moving parts • They have very low pressure loses ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 12

  13. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL5034 (single beam), FLOMIC FL5054 (dual beam) • Nominaldiameter:DN32 to DN300 (single beam), DN40 to DN300 (dual beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 13

  14. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL5034 (single beam) FLOMIC FL5054 (dual beam) • Material of sensor: weldment (measuring part is madefrom ss-steel 1.4403, flanges and cover from carbon steel) • Connection: flanges (EN, ANSI, JIS) • Water pressure class: MAP16, MAP40 • Temperature class: T50 • Flow-profile sensitivity class:U5 (FL5044), U10 (FL5024) – in front of meter D3 (FL5044), D5 (FL5024) – behind meter • Pressure loss class: ∆P10 • Climatic and mechanical class: B • Electromagnetic environment: E1, E2 • Display unit: single-line 8 character LC display ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 14

  15. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL5034 (single beam) FLOMIC FL5054 (dual beam) • Flow rate sampling period:1 sec • Power supply: Li battery 3,6 V/19Ah – live time 8 years • Protection class: IP68 • Output: passive pulse output (U= 3 to 30V, I = 0,002 to 10mA, timp = 30ms) passive current output 4 to 20mA (U = 10to 24V) • Optional equipment: complete ss-sensor bi-directional measurement (± passive pulse output) passive current output 4 to 20mA in combinationofelectrical contact for flow direction USB, RS232 or RS232 + USB converter GSM module FLODAT FD1.00 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 15

  16. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL5034 (single beam) FLOMIC FL5054 (dual beam) • BASIC DIMENSIONS and WEIGHT ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

  17. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL3085 (single beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 17

  18. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL3085 (single beam) • Intended for measurement of clean water in big dimensions • Measurement of instantaneous flow rate in both directionandconsumption of water • Storage data • They don’t have any moving parts • They have very low pressure loses ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 18

  19. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL3085 (single beam) • Nominal diameter: DN200 to DN1200 • Material of sensor: weldment, material from carbon steel, painted • Connection: flanges (EN, ANSI, JIS) • Nominal pressure: PN6, PN10, PN16, PN40 • Temperature of liquid: 0 to 150°C • Ultrasonic transductors: 2 pcs of US2.1 (manufactured by ELIS PLZEŇ a. s.) • Display unit: single-line 8 character LC display • Power supply: Li-battery + 2 x Alkali batteries 9V, live time 4 years • Transductors connection cable: max. 20m • Accuracy: ±1% in range 1:20 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 19

  20. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL3085 (single beam) • Flow rate sampling period: 1 sec • Protection class: of electronic: IP65 • Protection of sensor: IP54/IP68 • Outputs: passive pulse output (U= 30V, I = 10mA) passive current output 4 to 20mA (U = 24V) • Optional equipment: complete ss-sensor bi-directional measurement (± passive pulse output) passive current output 4 to 20mA incombination of electrical contact for flow direction USB, RS232 or RS232 + USB converter ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 20

  21. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL3085 (single beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 21

  22. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL3005 (single beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 22

  23. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL3005 (single beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 23

  24. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL3005 (single beam) • Intended for measurement of clean water on big piping • Installation directly to existing piping • Measurement of instantaneous flow rate in both directionandconsumption of water • Theoretical calibration after installation • Storage data ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 24

  25. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL3005 (single beam) • Nominal diameter: DN200 to DN2000 • Nominal pressure: PN40 • Temperature of liquid: 0 to 150°C • Ultrasonic transductors: 2 pcs of US2.1 (manufactured by ELIS PLZEN a. s.) • Display unit: single-line 8 character LC display • Flow rate sampling period: 1 sec • Power supply: Li-battery + 2 x Alkali batteries 9V, live time 4 years • Transductors connection cable: max. 20m • Protection class of electronic: IP65 • Protection of sensor: IP54/IP68 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 25

  26. BATTERY POWERED ULTRASONIC FLOW METERS FLOMIC FL3005 (single beam) • Output: passive pulse output (U= 3 to 30V, I = 10mA) passive current output 4 to 20mA, (U = 24V) communication interface RS232 • Accuracy: ± 2% in range 1:20 • Optional equipment: bi-directional measurement (± passive pulse output) passive current output 4 to 20mA in combination of electrical contact for flow direction USB, RS232 or RS232 + USB converter ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 26

  27. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 27

  28. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) • Intended for measurement of non conductive and conductive clean liquids as water, demineralized water, condensate, fuel, diesel, oil • Measurement of instantaneous flow rate in both direction and consumption of water • Measurement of mass flow and mass of water with connection of temperature sensor Pt100 • They don’t have any moving parts • They have very low pressure loses ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 28

  29. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) • Nominal diameter: DN32 to DN300 • Nominal pressure: PN16, PN40 • Measurement accuracy: ±1% for velocity of liquid v>0,5 m/s (SE404X) • ±0,5% for velocity of liquid v>0,5 m/s (SE406X) • Temperature of liquid: 0 to 150°C • Ambient temperature: +5 to +55°C • Display unit: alpha-numerical LCD unit, 2 lines, 16 characters each • Power supply: 90 to 230V AC, 50 to 60Hz • Protection class: electronics IP65, sensor IP67 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 29

  30. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) • Material of sensor: weldment (measuring part is made from ss-steel 1.4301, flanges and cover from carbon steel) • Flow-profile sensitivity class: U5 (SE406X), U10 (SE404X) – in front of meter D3 (SE406X), D5 (SE404X) – behind meter • Outputs: pulse output (selected 0.1 to 1,000l/pulse) Frequency output, selected 0 t 1,000 Hz or 10kHz Relay type 24VAC/0,1A ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 30

  31. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) • Optional equipment: communication line RS485 extended temperature range for sensors: -20° to 180°C Current output (0)4 to 20mA Mass-flow rate measurement capability Flow rate measurement in two directions sensor protection class IP68 100 m (max.) transductors connection cable ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 31

  32. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) • METER VERSION, CONFIGURATION and TYPE DESIGNATION ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 32

  33. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE404X (single beam) SONOELIS SE406X (dual beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 33

  34. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE401X (singlebeam) SONOELIS SE402X (dual beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 34

  35. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) • Intended for measurement of non conductive and conductive clean liquids as water, demineralized water • Measurement ofinstantaneousflow rate in both direction and consumption of water • Measurement of mass flow and mass of water with connection of temperature sensor Pt100 • They don’t have any moving parts • They have very low pressure loses ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 35

  36. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) • Nominal diameter: DN200 to DN1200 • Nominal pressure: PN16, PN40 • Measurement accuracy: ±1% for velocity of liquid v>0,5 m/s (SE401X) • ±0,5% for velocity of liquid v>0,5 m/s (SE402X) • Temperature of liquid: 0 to 150°C • Ambient temperature: +5 to +55°C • Display unit: alpha-numerical LCD unit, 2 lines, 16 characters each • Power supply: 90 to 230V AC, 50 to 60Hz • Protection class: electronics IP65, sensor IP54 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 36

  37. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) • Material of sensor: weldment (material of measuring part flanges from carbon steel) • Flow-profile sensitivity class: U5 (SE402X), U10 (SE401X) – in front of meter D3 (SE402X), D5 (SE401X) – behindmeter • Outputs: pulse output (selected 0.1 to 1,000l/pulse) Frequencyoutput, selected 0 t 1,000 Hz or 10kHz Relay type 24VAC/0,1A ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 37

  38. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) • Optional equipment: communication line RS485 extended temperature range for sensors: -20° to 180°C Current output (0)4 to 20mA Mass-flow rate measurement capability Flow rate measurement in two directions sensor protection class IP68 100 m (max.) transductors connection cable ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 38

  39. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) • METER VERSION, CONFIGURATION and TYPE DESIGNATION ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 39

  40. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE401X (single beam) SONOELIS SE402X (dual beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 40

  41. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE804X (single beam) SONOELIS SE806X (dual beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 41

  42. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE804X (single beam) SONOELIS SE806X (dual beam) ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 42

  43. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE804X (single beam) SONOELIS SE806X (dual beam) • Intended for measurement of clean water on big piping • Installation directly to existing piping • Measurementof instantaneous flow rate in both direction and consumption of water • Measurement of mass flow and mass of water with connection of temperature sensor Pt100 • Theoretical calibration after installation ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 43

  44. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE804X (single beam) SONOELIS SE806X (dual beam) • Nominal diameter: DN200 to DN1200 • Nominal pressure: PN40 • Temperature of liquid: 0° to 150°C • Ultrasonic transductors: 2 pcs of US2.1 (manufactured by ELIS PLZEŇ a. s.) • Display unit: single-line 8 character LC display • Power supply: 90 to 250VAC, 50 to 60Hz • Transductors connection cable: max. 100m • Protection class of electronic: IP65 • Protection of sensor: IP54 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 44

  45. MAIN POWEREDULTRASONIC FLOW METERS SONOELIS SE804X (single beam) SONOELIS SE806X (dual beam) • Output: passive pulse output (U= 3 to 30V, I = 10mA) passive current output 4 to 20mA, (U = 24V) communication interface RS232 • Accuracy: ± 2% in range 1:20 • Optional equipment: communication line RS485 extended temperature range for sensors -20° to 180°C Current output (0)4 to 20mA Mass-flow rate measurement capability Flow rate measurement in two directions sensor protection class IP68 100 m (max.) transductorsconnection cable ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 45

  46. Thank you for your attention ELIS PLZEŇ a. s. Luční 15 301 64 Plzeň Czech Republic Phone: +420 377 517 751 Fax: +420 377 517 722 E-mail: sales@elis.cz http://www.elis.cz ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 46