LARGE GROUP MANUFACTURERSUPDATE ORLANDO, FL FRIDAY – APRIL 12, 2013 3:00 P.M. – 5:00 P.M.
NUAIRE PRODUCTS
PRODUCT UDATES • 2012 NU-481, Class II A2 special BSC for Chemo use • 2012 release of NU-58XX DH incubator line • 2012 release of NU-201 / 301 products with DC ECM Motor (Series 60) • 2012 release of NU-813 (Series 30) • 2012 Intro of Awel line of Centrifuges • 2012 Intro of NU-677, Slanted, 12 inch, NSF Listed, 400, 500, 600
NUAIRE PHONE NUMBERS • 800-328-3352 - Live Operator • 888-4-NuAire, (888-468-2473) Enter Ext. • Walt Johnson – 241 (Part-time) • Jim McGowan - 256 • Joe Bartee - 283 • Greg Garelik - 239 • Al Newton – 274 • Steve Winget – 523 • Adam Christensen-527 • Jack Orloff - 255 • Fax Number 763-432 4006
NEW PRODUCT WARRANTY • Centrifuge 24 Months • Standard Airflow Products 36 Months • A2/B1/B2 models w/DC-ECM motor 60 Months • Laminar 60 Months • Incubators 24 Months • Freezers 24 Months • Polypropylene Hoods / Casework 12 Months • Special Products 12 Months
18 9 1 7 6 0 1 1 4 0 4 Unit Specific Number MM/DD/YY SERIAL NUMBER ID
RETURN PARTS • Need NuAire Approval • RG Number • Defective Part Tag • Decon Papers • Promptly Return Parts
UV BALLAST RETROFITS • UV Ballast have changed through the years from vendor • Prior to the fall of 2008 4 wire ballast • 2008 to the fall of 2012 3 wire ballast • 2012 to present 4 wire ballast • When replacing a UV Ballast for cabinets with a 3 wire ballast a decon will need to be performed since the current ballast is a 4 wire configuration.
ELECTRONICALLYCOMMUTATED MOTOR • ECM 5.0 Genteq Motor • 1450 RPM • 10” Forward Curved Fan (was 9”) • PWM (DC signal) varies the motor speed • Motor Control, Monitors RPM and torque which delivers constant air volume as HEPA Filters load • NU-437, NU-440, NU-475, NU-477, NU-480, NU-481, NU-629, NU-677 (A2 units) • NU-427 (B1), NU-430, NU-435 (B2) - DC ECM Motor is standard • Optional on NU-425 (A2)
STB0187 DC ECM MOTOR UPGRADE • Converting a NU-425 Series 20 and newer from an AC to a DC Motor 115V (Standard) • All other BSC Models Series 20 and Newer are Specs
DC ECM CONTROL SYSTEM A2 • NU-425 – ES (Energy Saver) - Optional & Field Upgradeable • NU-475, NU-629 – ES (Energy Saver) – Standard
12 Volt DC Power supply Automatic Constant Airflow volume Thru motor rpm feedback Manual Airflow volume adjustment (POT) On-board jumper positions for correct cabinet size Speed Cont. locks in setting after 1 Minute idle or certifier sets via push button & LED turns off DC SPEED CONTROLLEROPTIONALON NU-425
SPEED CONTROLLER JUMPERS J2 J3 0 = Not Jumped 1 = Jumped
GENERAL AIRFLOW BOARD (GAF) • NU-437, NU-477, NU-677 (A2) – ES (Energy) -Saver Standard • GAF Also used in NU-813 , NU-126 , NU-619 - Change Station & All Isolators models
AC Motor Output: Older Series NU-437 AC Impeller Output: Older Series NU-813; NU-126; NU-619 and Isolators DC ECM Motor Output: Std. on Current NU-437, NU-477, NU-677 DC EC Impeller Output: Std. on All Isolators (S-10^) NR/NTE/PR; NU-813, NU-126, NU-619 Latest Software Release (Rev 1.5.0001), STB0201 Corrects increase motor speed (PWM signal) due to site specific events, (i.e. power fluctuations, frequent on/off cycles) STB0202: RF Upgrade Installation Instructions GAF CONTOR BOARDMULTIPLE BLOWER CONTROLS
NU-437 (SERIES 60^) / 477/677)AIRFLOW CALIBRATION The DC-ECM System works like this: AC voltage is applied directly to the DC motor’s control module The motor control module (Microprocessor) converts the AC to DC for Internal electronics and to power the motor In addition, there is a second electrical cable that goes from the Main Control Board’s speed controller DC output to the motor. This generates a pulse-width-modulation (PWM) 2.5 – 8 VDC control signal and returns an RPM feedback signal from the motor to the speed controller CKT
GAF AC/DC MOTOR / IMPELLERAIRFLOW ADJUSTMENTS • AC motor – Airflow adjusted via the POT located under heat-sink • DC ECM motors - Airflow adjusted via sequence of control panel keys actions. Cal mode = press & hold Alarm Silence key, hit FL light on, light off key; Increase Airflow = UV key and decrease = FL light key • DC EC impellers utilize another set of potentiometers, on GAF board, Std. all Isolators (S-10^)
AC Blower POT. AC T.P.’s Board AC Input Connection EC #2 VDC T.P.’s EC #1 VDC T.P.’s EC Connector and POT #2 EC Connector & POT #1 DC ECM Blower 4 Pin Motor Control Connector GAFMAIN CONTOR BOARD LAYOUT AC Blower Output
Cut Jumper Wire for AC Motor GAF BOARD AC OR DC MOTOR SEKELTON JUMPER WIRE
NU-437/477/677FLOWGARD CALIBRATION Once the airflow calibration is complete – calibrate the FlowGard Airflow Monitor • Press and hold ( ) and ( ) arrow keys simultaneously for 3 seconds until the center green LED blinks. • Allow the Unit to run for a minimum of 2 minutes. • Press RESET Key to enter the nominal airflow value; the Green LED will stop blinking and display normally. This sets the high/low alarm limits +/-0.13 w.g. from nominal. Reference the operation manual for the NU-437/477 for more in-depth information and calibration procedures. If you require help, or have questions, contact NuAire’s Technical Support Depart.
FLOWGARD / DIGITAL MANOMETER STB0153 RETOFIT / UPGRADE
FLOWGARD / DIGITAL MANOMETER STB0153 RETOFIT / UPGRADE
FLOWGARD OR DIGITAL MANOMETER REPLACEMENT RF458 (437) / RF562 (797) • RF Kits include STB0153 and adaptor tubing Previous 2012 & Newer
The CellGard HD (Hazardous Drug) ES (Energy Saver) Class II, Type A2 Biological Safety Cabinet offers personnel, product and environmental protection for handling of hazardous particulate drugs and powders CELLGARD™ HD NU-481 ES
Clean Oval Canister HEPA Filtered Air Clean HEPA Filtered Air Room Air Contaminated Work Surface Air CELLGARD™ HD NU-481 ES AIR FLOW
The Ease of Bag-In / Bag-Out Remove Work Surface Remove paper catch grill over each oval HEPA prefilter Seal contaminated interior of each oval HEPA prefilter Remove four (4) fasteners per each oval HEPA prefilter Bag-Out used oval HEPA prefilter and replace CELLGARD™ HD NU-481 ES
Set the NU-481 into calibration mode Go to Sensor Setup / Calibrate Downflow Sensor / Blower Duty Cycle Set Blower Duty cycle to the RPM at the current calibrated airflow velocity Keep blower at this RPM (constant) throughout testing process Remove the work tray CELLGARD™ HD NU-481 ESPRIMARY HEPA FILTERINTEGRITY TESTING
PAO Wand Filter Gard CELLGARD™ HD NU-481 ESPRIMARY HEPA FILTERINTEGRITY TESTING
Filter Gard is used to direct the PAO from the wand into one area of prefilter at a time Filter Gard can be used for initial certification and after 1st annual certification Replace HEPEX Gard (B-481-8691) Fiberglass rods can be re-used CELLGARD™ HD NU-481 ESPRIMARY HEPA FILTERINTEGRITY TESTING
Move PAO Wand throughout filter, rotating the filter guard Leak is detected if a sustained leak rate greater than .005 is detected at the challenge port on top of the cabinet CELLGARD™ HD NU-481 ESPRIMARY HEPA FILTERINTEGRITY TESTING
TOUCHLINK ELECTRONIC CONTROL SYSTEM
Revision Notifications are sent out to all service organizations Revisions are available free of charge Use RF484 to order latest revision and cable connections TouchLink Software 61N.138N. (June 2011) (old boards) Old Boards upgraded to New (RF 567/572) STB0227 New Board – 61.37 New display with LED backlight Flash drive to upload new software or download history data (PTB0237) BAC/NET Compatible TOUCHLINK SOFTWARE UPDATES
OLDER TOUCHLINKEC SYSTEM PTB0170 No more chips – uses RF484 to update software Connect RJ45 White Cable (X-999854-01) to the board here
TOUCHLINKDOWNLOAD WITH USB FLASH DRIVE – PTB0237 U P G R A D I N G S O F T W A R E
PLUG THUMBDRIVEINTO USB PORT
USB SCREEN ONCE DRIVER PRESENCE IS DETECTED
READY TO START PROGRAMMING THE NXP
NXP PROGRAMMING COMPLETED SUCCESSFULLY
TOUCHLINKDOWNLOAD WITH USB FLASH DRIVE – PTB0240 P E R F O R M A N C E H I S T O R Y
USB SCREEN ONCE DRIVER PRESENCE IS DETECTED
MESSAGE WHILE UPLOADING PERFORMANCE DATA
MESSAGE ON COMPLETION OF DATA UPLOAD
CABINET DATA FORMATTED INTO EXCEL
BACNET BACnet A Data Communication Protocol for Building Automation and Control Networks • BACnet is a ANSI, EN, ISO global standard • Addresses both hardware and software applications • Provides method to share information
TOUCHLINK 2012 UPDATE INSTALLBACNETDAUGHTERBOARD