1 / 42

CO 2 Heat pump Kick Off Meeting The Natural Refrigerant, The Natural Choice

CO 2 Heat pump Kick Off Meeting The Natural Refrigerant, The Natural Choice. Maarud gård, Norge. 22 April 2008. SANYO Air Conditioners Europe Kjell Lundén. Looking at the house you have to consider:. Which year the house was built and ev. improvements.

alton
Download Presentation

CO 2 Heat pump Kick Off Meeting The Natural Refrigerant, The Natural Choice

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CO2Heat pump Kick Off MeetingThe Natural Refrigerant, The Natural Choice Maarud gård, Norge 22 April 2008 SANYO Air Conditioners Europe Kjell Lundén

  2. Looking at the house you have to consider: • Which year the house was built and ev. improvements • Number of residents • Living area (heated area) • Energy consumption • Plot of land and its location

  3. Windows +5° 0° -5° -10° -15° 2-glass windows Standard 3-glass windows Energy effective 3-glass windows

  4. Where goes the energy? Ventilation 30% Roof 15% Windows 25% Outer walls 15% Floor & Basement 15%

  5. Old plankhouse with extreme highenergy consumption Roof U=0.5 Windows U=3.0 Outer walls U=1.0 Base U=1.0

  6. Usage of energy Household electricity 5000 kWh/year Heating of the house 15000 kWh/year or around 60% Hot water 5000 kWh/year

  7. Energy for heating / year Maximum power requirement at lowest temperature -30° T e m p e r a t u r e / e f f e c t 60% of the highest power requirment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Days 50 100 150 200 250 300 350

  8. Kostnadseffektivitet • - 1990: Vedeldning • 1990 - 2005: Bergvärme • 2005 - ? : Sanyos CO-2 teknik Borrhål

  9. Att tänka på • Tidigare energiförbrukning ska kunna motsvaras av värmepumpen. • Viktigt att kunden håller en så låg framledningstemperatur som möjligt. • Fler radiatorer eller luftkonvektor sänker framledningstemperaturen. • Tumregel: Framledningstemperaturen bör aldrig överstiga 50°C, för optimal besparing. • Rekommendera alltid markstativ.

  10. Plumbing 01 Sanyo CO2 Eco 02 Mixing valve, automatized 03 Circulation pump, radiator system 04 Adjustment valve for radiator coils 05 Radiators 06 Radiator thermostatic valves 07 Shut off valve for the radiator system 08 System/boiler pressure, install on the return pipe 09 Expansion vessel, closed (recommended) 10 Expansion vessel, open (alternative) 11 Filling valve for radiator system 12 Safety valve (factory mounted) 13 Safety valve for hot water coil 14 Mixing valve for hot water 15 Non-return valve for incoming cold water 16 Taps 17 Incoming cold water 18 Load circulation pump 19 Insulated pipes 20 Flexible houses 21 Heat pump unit 22 Shut-off valves 23 Drain valve

  11. Installation of systems with radiators Heating circuit Water Supply Outdoor Indoor HP Unit Radiator 931 Mix.V Tank Unit 1230 Circulation between HP and tank 597

  12. Installation of systems with radiators and floor heating Heating circuit Outdoor Water Supply Indoor 931 Radiator HP Unit Mix.V Tank Unit Floor heating Mix.V 1230 Circulation between HP and tank 597 ND10

  13. ?????????

  14. Tank structure Returledning till Nedre skikt Övre skiktplåt Ifrån VP till tankens mellanskikt Nedre skiktplåt Till VP ifrån Nedre skikt

  15. Tank Structure 2

  16. Limitations Pipe maximum length 15 m

  17. Limitations

  18. Rörchema

  19. Electrical parts

  20. Wiring

  21. Wiring

  22. Wiring

  23. Connections

  24. Elinkoppling

  25. PANEL

  26. Display normalläge CO2 ECO RUM 21 °C (21.5 °C) Tanktemp. 50 °C Ute temp. 3 °C Status: Måndag 20:45 Manuell avfrostning Nej

  27. Huvudmeny Logg Diagnos Inställningar Inställningar kodad Manuell drift (Inställning tid)

  28. Meny Logg • Total drifttid 15351 h • Total kompressor 7350 h • Kompressor/24 h 17:32 h • Start komp./24 h 2 • Senast larm: • Utegivare • - • -

  29. Meny Diagnos sid 1 Kompr effekt 82 Hz Elpanna 0 kw Elpanna temp (55°C) 55°C El nedre 0 kW El nedre temp 45°C Rumstemp (21,5 °C) 21 °C Utetemp 3 °C Tanktemp (50 °C) 44 °C Radiator temp (40 °C) 40 °C

  30. Meny Diagnos sid 2 Ström (25A) 12A Shuntventil + Laddpump 99% VP vatten in 37 °C VP vatten ut 55 °C Kompr temp 90 °C Utetemp VP 1 °C Fördröjn. El Ej aktiv

  31. Meny Diagnos sid 3 Kommunikation OK Program ID XXXXXXX Program datum XX-XX-XX

  32. Meny Inställningar sid 1 Språk Swe Värmepump Ja Huvudsäkring 20 A Fördröjning elpanna 3 h Elpanna 50 °C Max elpanna 6 kw El nedre 45°C Max el nedre 6 kW

  33. Meny Inställningar sid 2 Sommargräns 17°C Rumsgivare Ja Max framledning 55 °C Min framledning Av Huskurva 50 °C Justering Huskurva 0 °C Temp sänkning Nej Rum / Framl ändras 0 °C

  34. Meny Inställningar sid 3 Tider Måndag ▲06▼--▲--▼22 Tisdag ▲06▼--▲--▼22 Onsdag ▲06▼--▲--▼22 Torsdag ▲06▼--▲--▼22 Fredag ▲06▼--▲--▼22 Lördag ▲06▼--▲--▼22 Söndag ▲06▼--▲--▼22

  35. Meny Inställningar kodad 276 Kod 276 Tank Max 65 °C Tank Min A 43 °C Tank Min B 50 °C Tank min gräns 5 °C Min Pump hast 10% Diff Start / Stopp 5 °C Frysgräns 2 °C

  36. Meny Manuell Värmepump ( ) Pumphast 0% Relä 1.5( ) 3( ) 4,5( ) 6( ) 7,5( ) 9( ) Relä nedre 3() 6() Shuntventil ( ) Rumsgivare fel ( )

  37. Meny Inställning tid Inställning Tid Måndag Timme 00: Minut 00:

  38. Let’s go with the natural choice!

More Related