SMART METER TEXAS. Status Update And FTPS Technical Integration Details. February 25, 2010. AGENDA. Release 1 Status Update Smart Meter Texas Activity Since February 1, 2010 Go Live New one on one REP SMT FTPS Integration Process Upcoming Events Information Questions and Responses
E N D
SMART METERTEXAS Status Update And FTPS Technical Integration Details February 25, 2010
AGENDA • Release 1 Status Update • Smart Meter Texas Activity Since February 1, 2010 Go Live • New one on one REP SMT FTPS Integration Process • Upcoming Events Information • Questions and Responses • Open Floor Discussion and Additional Questions • FTPS Specific Integration Technical Questions IBM Confidential
Smart Meter Texas Release1 Status Update Notice to Market February 22, 2010 As previously stated, on Monday, February 1, 2010, the soft launch of Smart Meter Texas (SMT) delivered integration with the TDSP’s, including retrieval and processing of LSE 15-minute interval data from the FTPS site and access to APIs for AdHoc usage information and HAN functionality. The SMT team is currently holding work sessions for set up on FTPS interval data (this is the raw data held in the data repository) and API integration (for machine-to-machine provisioning of HAN devices). These sessions are being provided to the REPs on a first-come first-serve basis. An announcement, with greater detail, can be found at http://www.puc.state.tx.us/electric/projects/34610/34610.cfmThe “Tiger Team” has concluded its assessment and has determined the following rollout plan. In March, the SMT will be fully available for its public, but without Registration or User Management for the REP community. This piece is expected to be available in May. As an interim solution, the SMT Host/Help Desk will coordinate the registration process for REP administrators and REP users on behalf of any REP who is ready to set up their access.
Smart Meter Texas Release1 Status Update Notice to Market February 22, 2010 • The SMT TDSP consortium has been assured that this functionality will be available in March: • Residential and non-residential customers (NRC) users can: • Self register • View their energy usage and graphs • View a list of active HAN devices • · REPs / TDSPs can: • View ESIIDs, meters, usage, graphs, HAN devices and request ad hoc usage • Provision and de-provision HAN devices • REP Admin and TDSP Admin will have HAN rights • SMT Host (Help Desk) authenticates, registers, and manages Admins and Users • · Initial Limitations: • Max users in an entity cannot exceed 25 • NRC limited to one Admin/user via self-registration. • On exception basis, additional NRC users can be added by SMT Host • SMT Host manages registration, user management, and profile updates for REPs and TDSPs • In March, we will provide a Go Live update which will include further instructions on how you can initiate your registration.
Smart Meter Texas Release1 Status Update Activity Since February 1 • 710,000+ AMS meters are stored in the SMT data repository and are actively loading LSE data from the TDSPs since January 29, 2010 • 30+ REPS have requested the FTPS and API specification documents and are investigating integration with Smart Meter Texas • Activity surrounding FTPS integration is increasing in momentum with REP interest and questions to the SMT team • Due to FTPS integration interest and learning from current process, SMT is introducing a new one-on-one REP FTPS integration process
Smart Meter Texas Release1 Status Update Activity Since February 1 • Available data statistics from SMT Production Data Repository as of 2/22/2010
Smart Meter Texas Release1 Status Update Activity Since February 1 • Number of AMI meters with interval & daily register reads processed per day (combined Oncor & CNP)
New REP one on one FTPS Integration Process • Learned from existing process • Two one hour sessions are not needed for FTPS integration discussion • More one on one short interfaces for Q and A are needed • Can be more responsive through scheduling one-on-one emails, calls, and interface sessions • Will increase number of REPs FTPS integration per week • Designed new one-on-one process • No longer sign up for group work sessions • Contact Jenina for insertion into process flow • Provide Jenina with requested information jenina.smith@solutionscubegroup.com • SMT FTPS integration process central point of contact that will work with you will be Brett Simon brett.c.simon@us.ibm.com • Will receive one-on-one assistance, emails, calls, Q and A and private FTPS integration session scheduling to meet your personal schedule • Implemented new process as of today IBM Confidential
New REP one on one FTPS Integration Process IBM Confidential
Up Coming Events • February 25th release of new one on one REP FTPS Integration Process • February 23rd 2-4PM and February 25th 10-noon API Integration WebEx Work Sessions – 3 REPs Signed Up • March 2nd 2-4PM and March 4th 10-noon API Integration WebEx Work Sessions – 3 REPs Signed Up • March 4th 8:30 AM SMT Status • March 11th 8:30 AM SMT Status IBM Confidential
Questions and Responses • Describe the current SMT process regarding customer / REP access to SMT data when there is a move-in or move-out. Include timeline and describe which EDI transactions trigger an action in SMT. When does the customer lose access and when does the REP lose access? When does the new REP of Record and new customer get access? The development of business process flows to support the answer to this and other questions concerning process and timing etc are being developed as part of task 197 and will be available to the market shortly. IBM Confidential
Questions and Responses • Can the TDSPs share some data that shows a percent of intervals complete and register reads complete with actual data in the 10 days following the operating day? At present, each of the TDSPs are providing to the Smart Meter Texas portal interval usage information in the LSE format. The LSE file contains a denotation which defines whether the information is actual or estimated, and can be used to calculate the requested percentages. It should be recognized that the overall percentages will vary over the next couple of years until the deployment processes have been completed and AMI environment matures. IBM Confidential
Open Floor Discussion and Questions Open Forum IBM Confidential
SMART METERTEXAS REP FTPS Technical Integration Details February 25, 2010
SMT FTPS File Naming Convention FTPS Folder and File Naming Convention: Here’s the LSE file naming convention and link to MARS documents http://www.ercot.com/committees/board/tac/rms/marstf/ FTP server contains two folders on each REP FTPS Sites # 1 for posting the Daily LSE files received from the TDSPs # 2 for posting the usage response files generated for the Ad Hoc usage requests received from the REP users via SMT Portal or API call. #1 Folder Name – “intervaldata” Contains the LSE files SMT received from the TDSPs . Example file: 957877905IntervalData20100122123001980.lse.002.799530915 #2 Folder Name – “adhocusage" Contains the SMT generated CSV/LSE files for the adhoc usage requests Example files: IntervalMeterUsagecfd024ab76ee195c3c326fe9.CSV.8286294561000 IntervalMeterUsagecfd024ab76ee195c3c326fe9.lse.8286294561000 DailyMeterUsage00122c501ff160ca73ad74a7.CSV.799530915
Testing Testing Obtain Obtain Obtain ftps Obtain ftps Provide Public Provide Public Coordinate Coordinate Credentials Credentials Client Security Client Security PGP Key PGP Key Download Download And Addresses And Addresses Certificate Certificate to SMT to SMT Testing With Testing With For SMT Staging For SMT Staging (from Verisign) (self signed) (self signed) (self signed) SMT SMT Env. Env. Allow 1 Allow 1 - - Register Register on Portal on Portal 2 weeks 2 weeks Production Production Obtain Obtain Obtain ftps Obtain ftps Provide Public Provide Public Exercise Exercise Credentials Credentials Client Security Client Security PGP Key PGP Key Production Production And Addresses And Addresses Certificate Certificate to SMT to SMT Usage Usage For SMT For SMT (from Verisign) (CA signed) (self signed) (self signed) Downloads Downloads Production Production SMT Technical Information required from REPs* Usage Download Technical Setup Overview * Completing this setup will allow REPs to retrieve their daily usage files via ftps.
SMT Technical Information required from REPs REP instruction: Select an FTPS-capable client Obtain REP FTP user ID and password from SMT Operations Obtain and install FTPS Client certificate from VeriSign, per FTPS-client instructions. [FTPS-specific] Generate PGP key pair Provide PGP public key and REP SSL public certificate to SMT host administrators Configure client if applicable with FTP user ID for SMT login Obtain SMT server address and configure client for connection setup Access FTPS server – enter FTP User ID and password to authenticate, to start. The FTPS client will then use the certificate with the FTPS server to establish an encrypted SSL session.
Thank You For The Opportunity To Discuss SMART METERTEXAS