An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Anodizing Power SourceGroup 35 ECE 445 – Senior Design TA – Bryan Dobbs

  2. Group Members Peter Hwang Hung Chung Kofi Kwarteng

  3. Objectives of our design To be able to build a complete packaged anodizing power source for use in the anodizing shop in Everitt Laboratory.

  4. Benefits to the customer (Anodizing shop in Everitt Laboratory) • Ability to supply power to the anodizing shop • Adjustable current so that the client can adjust the current to his/ her needs • Low cost • High efficiency • Safety features to prevent injury to user

  5. Product Features • Clean, adjustable dc current via a user-controllable knob • Start/ Stop switch • Ground referenced output and isolated from the input • Fuses for over current protection • Fan for temperature regulation

  6. Design – Block Diagrams 3 phase Rectifier and Filter 3 phase AC source Full-bridge AC link and Forward Converter Current Sensor DC Load Feedback and Switch Control

  7. Phase Shift Delay Control • Main aspect control of the converter will come from the voltage source inverter (VSI) which has phase shift delay. • By adjusting the phase shift delay δ, the average value of the output voltage can be controlled. • The δ parameter is controlled by a PWM chip through the feedback signal of the output current.

  8. Step Down Transformer • The main transformer to be used is a high frequency transformer • This transformer will step the inverted voltage down from about 160V to 40V.

  9. Feedback Control • The equation that models the feedback control is given as K = ki∫ (Vref-vout) dt + kp(Vref-vout) • This integral control compares the reference signal to the measured signal and the signal (Vref-vout) will rise when the error is positive, fall when negative and remain constant even when the error is zero.

  10. Output Current Ripple • Our design encompasses limiting the current ripple to 2%. At 120A, current ripple is +/- 1.2A. • At a switching frequency of 20kHz, the required inductance is L = V(DT)/Δi =40V(0.5)(5E-5)/2.4 =416.7uH

  11. Performance Requirements Expected output includes: • 120A dc current output • About 40V dc voltage output • Output current to be controlled by the user • User interface incorporates a start/ stop switch pair • Input source of 208V ac which will be three phase • Output to be ground referenced and isolated from the input • Current ripple to be less than 2% • Efficiency to be greater than 75%

  12. Initial Testing Procedures • PSPICE simulations • Testing of individual components • Assembling individual components and testing at small current levels

  13. Challenges and Difficulties • Getting PWM chip to work • Non-availability of high current for testing parts • Getting certain parts, e.g. type of wire to be used in winding transformer and inductor

  14. What were done and could have been done • We got the right transformer core finally and winding wire • PWM problem was not solved conclusively

  15. That’s pretty much it Questions?