An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Vanderbilt Senior Design 2010:Non-Electronic Blood Pressure Assist Device Members: Laura Allen (ChBE) James Berry (BME) Casey Duckwall (BME) David Harris (ChBE) Mentor: Prof. Baudenbacher

  2. Blood Pressure Assist Device • The Engineering World Health (EWH) Organization proposed the challenge: • Can a mechanical adjunct for a sphygmomanometer be designed to amplify the oscillatory pressure signal? • Can the design be used by minimally trained users to identify at least systolic pressure? (Ideally diastolic too)

  3. Developing World Usability • Self-sustainable • Power supply from mechanical or solar means • Low Cost: Less than $10 • When produced in quantities of 5000+ • Mechanical adjunct to sphygmomanometer • Eliminating the need for Korotkoff sound identification • Identify at least systolic • Pictorial instructions for all users

  4. Rationale • Cardiovascular diseases kill more people worldwide than any other disease1 • Even a leading cause in developing nations, where AIDS and malaria receive greater attention • Hypertension is a primary risk factor for cardiovascular illnesses • Managing blood pressure is vital for long-term health of cardiovascular disease patients2 • Diagnosing hypertension can be challenging in developing countries

  5. Literature Review • Patent search did not reveal any useful information • Researched the science behind blood pressure • Investigated different methods of measurement • Identified a range for oscillation frequencies

  6. Preliminary Data Collection • Findings indicate that measuring blood pressure by observation of sphygmomanometer alone is unreliable • Our final design should be within ±10mmHg per reading, taking into account that normal blood pressures vary by ±3mmHg with each beat

  7. Results from Commercial BP Device • Commercially available electronic blood pressure devices in the range of $40 yielded extreme variations in blood pressure readings, going so far as to place some individuals in both stage 2 hypertension as well as hypotension. • Furthermore, these readings were extremely variable between measurements on the same individual, varying by more than 20mmHg for systolic.

  8. Project Budget

  9. Circuit Specification • An electronic approach yields 5 new design elements • Power Supply • Filtering • Amplification • Readout • Transducer

  10. Circuit

  11. Power Supply • Reusable • Solar cell - $3.45 in bulk • 3.4V, 25mA • Sufficient voltage output • ±3V operational amplifier rails • ~2V LED, 20mA

  12. Filtering and Amplification • Literature suggests frequency range of 20-80Hz • First-order active filtering using • High-pass filter > 10Hz • Low-pass filter < 100Hz • Amplify signal to approximately 2V in passed range

  13. Output • Two monochromatic LED • 1) Power light - Demonstrate sufficient power to the device • 2) Indicator light – Light up during pass-band frequencies

  14. Transducer • Pressure Sensor: $3.65 in bulk • NovaSensor NPC-100 • Developed for usage in biomedical diagnostics • Sensitivity ±1% • 5µV/V/mmHg • Linearity ±1% • For physiological range • Full range -30mmHg to 300mmHg • Test operating resistance to compute peripheral resistor values

  15. References • WHO. “Fact Sheet: The Top Ten Causes of Death.” WHO. November 2008. Accessed October 28, 2009 http://www.who.int/mediacentre/factsheets/fs310_2008.pdf • Pickering TG. , Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, Jones DW, Kurtz T, Sheps SG, Roccella EJ; Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension. 2005 Jan;45(1):142-61.