260 likes | 650 Views
Asahi/America Actuation-Electric & Pneumatic Asahi/America Actuation Actuator Packages State of the Art Design Ability to Interface In-House Manufacturing Specials Over 25 Years Experience Asahi/America Actuation Markets Water Purification Waste Treatment Chemical Landfills
E N D
Asahi/AmericaActuation • Actuator Packages • State of the Art Design • Ability to Interface • In-House Manufacturing • Specials • Over 25 Years Experience
Asahi/AmericaActuation Markets • Water Purification • Waste Treatment • Chemical • Landfills • Aquariums • Off Shore Applications • Semiconductor
Asahi/AmericaElectric &Pneumatic Actuators Series 83-Electromni Series 94-Quartermaster Series 92-Quartermaster Chief Series 79- Pneumatic
Asahi/AmericaActuation Actuator Packages (Multiturn) (90-180 Electric) (90 Pneumatic)
Asahi/AmericaActuation State of the Art Castings Strength Test
Asahi/AmericaActuation Ability to Interface
Asahi/AmericaActuation In-House Manufacturing
Asahi/AmericaQuality Control ISO 9001 Certified
Asahi/AmericaQuality Control Actuation • Design Life 250,000 cycles minimum • Assembly Process • Parts Inspection • 100% Testing • Serializing • Appearance
Asahi/AmericaActuation Electric Actuator Terminology • Reversing/Unidirectional • Duty Cycle • Nema Ratings • Switches • Flow Control Loop
Asahi/AmericaActuation Unidirectional: Rotates in one direction only and stops every 90 degrees until signaled to move again. Reversing: Rotates clockwiseto open a valve and counterclockwiseto close a valve.
Asahi/AmericaActuation Electric Actuator Design-Spur Gear Stator Capacitor Gearbox Motor • Pinion Gear Main Output Gear
Asahi/AmericaActuation Duty Cycle Duty Cycle is the ratio between actuator cycle time and the “cool off” time required based on 100% to avoid thermal cut out. Example: 25% Duty Cycle means that the unit can be cycled 25%of the time. If the actuator is cycled for 1 minute continuously, Necessary cool off time is 3 minutes.
Asahi/AmericaActuation Nema Ratings (Non Hazardous Locations) • Type 1 General Purpose - Indoor • Type 2 Dripproof - Indoor • Type 3 Dusttight, Raintight and Sleet (Ice)-Proof - Outdoor • Type 3R Rainproof and Sleet (Ice)-Resistant - Outdoor • Type 3S Dusttight, Raintight and Sleet (Ice)-Proof - Outdoor • Type 4Watertight and Dusttight - Indoor and Outdoor • Type 4XWatertight, Dusttight and Corrosion-Resistant - Indoor and Outdoor • Type 5 Superseded by Type 12 for Control Apparatus • Type 6 Submersible, Watertight, Dripproof and Sleet (Ice)- Resistant - Indoor and Outdoor • Type 11 Corrosion-Resistant and Dripproof - Oil-immersed - Indoor • Type 12 Industrial Use - Dusttight and Dripproof - Indoor • Type 13 Oiltight and Dusttight - Indoor
Asahi/AmericaActuation Nema Ratings (Hazardous Locations) • Type 7Class I, Group A, B, C, or D - Indoor Hazardous Locations - Air-break Equipment • Type 8 Class I, Group A, B, C, or D - Indoor Hazardous Locations - Oil-Immersed Equipment • Type 9 Class II, Group E, F, or G - Indoor Hazardous Locations - Air-break Equipment • Type 10 Bureau of Mines
Asahi/AmericaActuation Nema Ratings (Hazardous Location Class & Divisions)
Asahi/AmericaActuation Nema Ratings (Hazardous Class & Divisions)
Asahi/AmericaActuation Nema Ratings ( Hazardous Class & Divisions)
Asahi/America Wiring Schematic Series 92
Asahi/AmericaActuation Aluminum 316 SS Plastic (Glass filled Polyamide)
Asahi/AmericaActuation Pneumatic Actuator Terminology • Designs • Double Acting (Air to Air) • Single Acting (Spring Return) • Switches
Asahi/America Actuator Types Double Acting (Air to Air): Requires air to open and air to close. No fail position if air supply is lost. Spring Return (Air to Spring): Requires air to open only, once air is exhausted springs close the valve. Fail position open or close if air supply is lost.
Asahi/AmericaActuation Double Piston Rack & Pinion Namur Dimensions Piston Rack Concentric Springs Pinion Double O Ring Sealing
Asahi/America Actuation-Switches SPST Line Voltage (Single Pole Single Throw) Used for Solenoid Valves SPDT Line Voltage (Single Pole Double Throw) Used for one Electric Actuator DPDT A Equipment (Double Pole Double Throw) Used for two Electric Actuators Line Voltage B
Asahi/America Flow Control Loop 4-20 ma Þ Ý Positioner Set Point Controller Actuator Sensor Valve