An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ATF Work Group Update ISAS January 12, 2011 Salt Lake City, Utah Pam Hunt – Chair, ATFWG

  2. ATFWG Activity Nothing going on…..except…. We’re Balanced – Always before the 15th We’re Guided – New WIT Guideline to approve And we’re Criteria-ed Out! – Working on WECC-0075-ATF Tagging Protocol - second go around. This is out for comments-due back January 27th.

  3. Discussion for Retirement of INT-002-WECC-CRT-1 • INT-002-WECC-CRT-1 (formerly INT-BPS-002)Requirement covered in: • B. Requirements: • WR1. Real-time operating personnel shall reconcile all BAL-004-WECC R4 • hourly Actual Interchange Telemetered values between • Adjacent Control Areas/Balancing Authorities after the • end of each clock hour. • WR2. After-the-fact (ATF) personnel shall verify the hourly The fact we reference that this must be done • Actual Interchange Telemetered Values per NERC Standard because of BAL-006 means it is • BAL-006-0 Section B, R.4. duplicative of NERC. • WR3. The hourly Actual Interchange Telemetered Values • shall be totaled to create the Control Area’s/Balancing • Authority’s month-end on-peak and off-peak NIA data BAL-006-R1-R4.2 • for submittal to the NERC Resources Subcommittee. • WR4. Control Areas/Balancing Authorities within the • WECC that adjust their month-end NIA values • by using month-end Actual Interchange Register • Meter Readings shall include these adjustments WIT Guideline • in the following calendar month’s NIA submittal Page 11-14 • to the NERC Resources Subcommittee (e.g. Actual • Interchange Register Meter Reading adjustments • for January will be included in the February month-end • NIA values).

  4. Discussion continued… • WR4.1 Inclusion of the Register Meter adjustments in the WIT Guideline • following calendar month’s NIA will avoid delays caused Page 11-14 • by the collection of the month-end Actual Interchange • Register Meter Readings. • WR4.1.1 Actual Interchange Register Meter Readings • are values manually or electronically read directly from WIT Guideline • the meter located at the point of interconnection between Page 11-14 • two Adjacent Control Areas/Balancing Authorities. The • meter could be measuring a tie-line point, remote load • metered point, or a remote generation metered point • for jointly owned generation. • WR4.1.2 Actual Interchange Register Meter Reads are BAL-006-R33 • the most accurate record available and are the primary • source to determine final NIAvalues. • WR5. Adjacent Control Areas/Balancing Authorities must • agree on the Actual Interchange Register Meter BAL-006-R4.1-R4.3 • Reading adjustments on each common interconnection WIT Guideline • prior to the submittal of the data to NERC. Page 11-14 • WR5.1 The Adjacent Control Areas/Balancing BAL-006--R4.2 • Authorities shall mutually agree on the distribution WIT Guideline • of the Actual Interchange Register Meter adjustments Page 11-14 • between on-peak and off-peak periods. • WR5.1 If the Adjacent Control Areas/Balancing Authorities WIT Guideline • cannot mutually agree on the distribution of the Actual Page 11-14 • Interchange Register Meter adjustments, the total adjustment • will be multiplied by 0.57 to determine the on-peak • adjustment and by 0.43 to determine the off-peak adjustment.

  5. Questions?