Cours AD1000 : Installation

ATSE. Cours AD1000 : Installation. Synoptique général. Éléments raccordés sur l’ AD1000. Lignes d'entrées :

brian-russo
Download Presentation

Cours AD1000 : Installation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ATSE Cours AD1000 : Installation AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  2. Synoptique général AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  3. Éléments raccordés sur l’ AD1000 Lignes d'entrées : Il est possible de contrôler 255 lignes d'entrées avec le tableau. Chaque carte d'entrées pouvant recevoir 32 points (sauf la première 31 pts). La commande se fait par présence ou absence de tension (No/Nf). La tension, pouvant être entre 12 à 48 volts, ne peut pas être prise sur le tableau. Asservissements : Les cartes d'asservissements peuvent sortir 31 ou 127 contacts secs contrôlés par logiciel. Ces cartes doivent être alimentées par une source extérieure. AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  4. Équipements déportés Moniteur déporté : Report à distance de l ’écran 5 pouces intégré au tableau. Raccordement avec du câble KX4 100m max.. Imprimante déportée : Report à distance , via la liaison RS422, des mêmes informations que l'imprimante interne du tableau. Dialogue PC : Permet le contrôle à distance jusqu ’à 8 tableaux AD1000 grâce à un ordinateur utilisé avec un logiciel spécifique. La liaison est de type RS422. Télédiagnostic et télésurveillance : Un minitel de type 2 est connecté en permanence à l ’AD1000. L ’utilisateur consulte et entre en dialogue avec le tableau grâce à un minitel de type 1 ou 2 (télédiagnostic). L ’AD1000 peut composer 2 numéros de téléphone afin de transmettre l ’information d ’alarme. Centralisation d ’alarmes incendie : Permet de centraliser jusqu’à 8 tableaux AD1000 su un micro ordinateur. Lorsqu ’une alarme intervient, le PC affiche: sur l ’écran monochrome, la localisation exacte de l ’alarme et sa consigne associée; sur l ’écran couleur, le plan et la situation de l'alarme. L ’imprimante raccordée au PC permet d ’éditer tous les évènements « au fil de l ’eau », et la consigne associée à l ’alarme. AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  5. Localisation des cartes AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  6. Intérieur du tableau AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  7. Alimentations du tableau AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  8. Carte REDO -1B- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  9. Carte ALI CH -21B- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  10. Carte DEF -25B- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  11. Carte ALG4 -29B- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  12. Carte 3S -33B- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  13. Carte ALI5 CPU-37B- (ALI 5 IMP-23H-) AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  14. Carte ZN4 -41B-(Zone1à4) : -45B-(Zone5à8) AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  15. Carte ALA -49B- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  16. Carte ADC -53B- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  17. Carte CPU -65B- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  18. Carte MEM(RAM) -69B- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  19. Liaison RS422 - Imprimante AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  20. Liaison RS422 - RS3PC AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  21. Liaison RS422 - AS100 AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  22. Carte VIDEO -77B- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  23. Carte ALI12(VIDEO) -28H- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  24. Carte COM -35H- AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  25. Carte Lignes d ’entrées - carte bornier 32 entrées Le système AD1000 peut contrôler 255 lignes d ’entrées maximum. Chaque carte d ’entrées peut recevoir 32 points numérotés de 1 à 32. AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  26. Carte Lignes d ’entrées - Cartes 8 inters AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  27. Carte bornier AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  28. Carte Bornier (1) AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  29. Carte Bornier (2) AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  30. Carte Bornier (2 New) AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  31. Carte AMPLI-ÉMISSION AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  32. TRAME TR2 AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  33. Éléments raccordés aux lignes de détection ICF (interface Feu) : ( 800µA en veille) Une ICF est une interface destinée pour la transmission d'informations de type incendie. Elle permet de connecter un ou plusieurs détecteurs/déclencheurs manuels sur une sous-boucle de détection. Elle transforme les variations de courant de la sous-boucle de détection en un signal de veille, d ’alarme feu, de défaut d'enlèvement détecteur (coupure ou court-circuit),transmis sur la ligne principale . ICT ( interface technique) : Une ICT est une interface destinée a transmettre une information de type technique. Elle ne transmet que deux états: veille (contact NF) ou alarme (contact NO). ICC (interface de commande de coupure de ligne principale) : Une ICC contrôle un secteur d'une boucle principale et permet, dans le cas de court-circuit, d'isoler la portion de ligne défectueuse pour laisser opérationnelle le reste de la ligne principale. Socle adressé : S2 - 1000 : ( 400µA en veille) Le socle adressé permet de localiser individuellement un détecteur (SO2-SO12-SO22-SO32) en lui attribuant une adresse. Déclencheur manuel adressé : DM 4250 - 1000 : Déclencheur manuel adressé muni d ’un micro contact inverseur et d ’un dispositif de test par introduction d ’une clef. AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  34. Détecteurs SO12 : Détecteur de fumée à ionisation. SO22 : Détecteur de chaleur thermovélocimétrique. SO32 : Détecteur de chaleur thermostatique. SO2 : Détecteur de fumée optique. SO42 : Détecteur de flamme ultraviolet. 4250 KR : Déclencheur manuel muni d ’un micro contact inverseur et d ’un dispositif de test par introduction d ’une clef. AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  35. Poids * 1 ICC tous les 32 points d ’alarme maximum, ou toutes les 3 zones maximum. • Le poids de la sous-boucle d ’une ICF ne doit pas dépasser 16. • Le nombre total de zones sur les 8 lignes doit être inférieur à 127. • Le nombre total de points sur les 8 lignes doit être inférieur à 1024. • Tension d ’alimentation : 15Vcc à 30 Vcc • Courant d ’alarme : 25mA • Courant de dérangement : 11mA AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  36. Exemple de raccordement AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  37. Raccordement Ligne de détection AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  38. Raccordement socle S2-1000 AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  39. Raccordement IK1000 AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  40. Raccordement ICF AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  41. Raccordement socle S2 sur ICF AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  42. Raccordement socle D.M. sur ICF AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  43. Raccordement ICC AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  44. Carte AS31 - E8 AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  45. Carte AS31 - E8 AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  46. Options de sorties carte - E8 Les cartes E8 ont toutes un fusible qui protège les sorties contre les courts-circuits et les surcharges. En cas de rupture du fusible, le voyant L1 s ’allume. AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  47. Carte AS31 - E16 AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  48. C.I. carte E16 AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  49. Carte AS127 AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)

  50. Pannes visibles sur l ’écran (TA=Test Alimentation) AD1000 Installation V1.1 Institut Johnson (M.H Fevrier 2004)