MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title. MET ONE 7000 Series. Agenda. MET ONE 7000 Series Overview Features and Benefits Part Numbers. Introduction to the MET ONE 7000 Series.

britain
Download Presentation

MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MET ONE 7000 SeriesRemote Airborne Particle CountersCustomer NameDatePresenterPresenter Title

  2. MET ONE 7000 Series

  3. Agenda • MET ONE 7000 Series Overview • Features and Benefits • Part Numbers

  4. Introduction to the MET ONE 7000 Series The MET ONE 7000 Series remote airborne particle counters, designed for ISO 21501 compliance, offers accurate, reliable, consistent and repeatable continuous particle monitoring. With a sensitivity range of 0.3 to 10 µm, the MET ONE 7000 Series is designed to meet the specific needs of cleanroom operations within the aseptic or sterile manufacturing facilities in the Life Science industry. • Designed for ISO 21501 compliance, ensures confidence in data accuracy, reliability and repeatability. • Flexible communication options and easy installation features allow easy integration of the remote counter with any FMS system. • The counter offers the most advanced instrument status and user notification indication feature available in the industry, saving troubleshooting and downtime related costs work.

  5. Multi-color status indicator LED Optional Relative Humidity-Temperature probe connection Service port for instrument set-up Also can be used for optional remote display unit (future enhancement) Optional remote indicator light port Introduction to MET ONE 7000 Series • ISO 21501 compliant design • Multiple I/O option • Built-in enhanced instrument status and user notification indicator • Long Life Laser™ • VHP tolerant flow path and optics • Wall plate, umbilical cords and tubes with quick connect fittings for ease of installation and removal • Up to 1000 sampling data storage • 0.3 µm sensitivity, 0.1 or 1.0 cfm flow rate • Built-in flow sensor option • Remote status indicator light option Standard 2 channel, optional 4 channel • Sealed enclosure with sealed connectors • RH-Temp probe option • Free set-up utility program

  6. First Counter Designed With ISO 21501 Compliant Capabilities • ISO 21501 is a new calibration standard replacing ASTM F328 and other similar existing standards • Accuracy in counting specific particle size • Significantly improved measurement repeatability from counter to counter • Reliability in accurate identification of particle sizes of interest that affect product quality and yield

  7. RJ 45 sealed connector for Ethernet, RS485 serial or Analog I/O Makes integration to any FMS easier Flexible Communication Options • Save FMS integration costs, repair and inventory related costs with multiple communications • Serial I/O (RS-485 with Modbus RTU or FX protocol) • Ethernet • Analog • Wireless

  8. AC or DC input power option Makes installation easier DIP switch for setting address of RS485 serial I/O instrument Makes installation and removal easier Quick connect type vacuum connector For ease of installation Ease of Installation Features • Easy installation with AC or DC input power options • 100~230 VAC 50/60 Hz house power • 24 VDC local power network • Reduces re-installation time during routine calibration and maintenance with DIP switch feature for serial units • Quick-connect type sealed vacuum connection

  9. User terminates wiring, tubing at the rear end of the wall plate Makes installation easier Umbilical cords and tubing supplied to connect the counter with wall plate For ease of installation and subsequent removal for routine calibration and maintenance. Ensure sealed connections Wall Plate - Front Makes installation and removal of counter easier Ease of Installation Features • Wall plate for terminating end-user cables and tubing, reduces disruption to connectivity during routine calibration • Umbilical with quick connect sealed connectors protect counter from wash down and make reinstallation easy • Quick-connect type sealed vacuum connection makes reinstallation during routine calibration easy

  10. Installation Features - Standard Accessories • Reduces initial installation time • Minimizes removal and re-installation time during routine calibration and maintenance • Provides wash-down tolerance with sealed umbilical and tubing

  11. Built in or optional remote multi-color status indicator LED Enhanced Instrument Diagnostics • Enhanced instrument status indication reduce troubleshooting time and downtime • Instrument can be diagnosed for flow, sensor, communication failures, and count alarm or count alert through built-in or external light indicator • Steady Green = Normal (set by software or internal) • Flashing Red = Count Alarm (set by software or internal) • Flashing Yellow = Count Alert (set by software only) • One short flash, one long flash Blue = Flow Fail (set by software or internal) • Solid Blue = Sensor Fail (set by software or internal) • Flashing Blue (2 Hz) = Communication Failure • (internally set based on communication timeout)

  12. MET ONE 7000 Series Setup Utility Program • Reduce set-up time with the MET ONE 7000 Series setup utility program • Local Setup • LAN Setup • Data Display • Reduce troubleshooting time • Run MET ONE 7000 Series remote counters without FMS software for troubleshooting • Obtain instrument information such as model, serial number and built in flow sensor

  13. Local Setup Screen Capture

  14. LAN Setup Screen Capture

  15. Data Display Screen Capture

  16. MET ONE 7000 Feature Summary

  17. MET ONE 7000 Series Monetization • Reliability in accurate identification of particles due to ISO 21501 compliant design that improves product quality and yield • Reduced troubleshooting time (labor), and less downtime • Standardized sensor irrespective of communication systems saving integration cost, repair time, downtime and inventory related costs • Reduced replacement parts cost and lower overall cost of ownership • Reduced removal and re-installation cost during routine calibration/maintenance work • Reduced risk of data loss due to communication disruption • Please use the monetization tab in the value selling document

  18. MET ONE 7000 Series Part Numbers How to Order

  19. Standard Shipment Includes