An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. On Wafer Ion Flux Sensors SFR Workshop May 24, 2001 Berkeley, CA Tae Won Kim, Saurabh Ullal, and Eray S Aydil University of California Santa Barbara 2001 GOAL: Build and demonstrate Langmuir probe based on wafer ion flux probe array using external electronics by 9/30/2001.

  2. Motivation and Goals • Variation of ion bombardment flux and its spatial distribution with plasma conditions is critical to plasma etching. • Ion flux uniformity at the wafer determines the uniformity of etching and etching profile evolution. • There have been almost no measurements of the ion flux or ion flux distribution across the wafer as a function of both r and q in realistic etching chemistry. • Design, build, and demonstrate an on-wafer ion flux analyzer with external electronics capable of mapping J+ (r,q) on a wafer.

  3. On Wafer Ion Flux Array • 10 probes on 3” wafer • Evaporated metal on PECVD SiO2 on Si wafer. Lines insulated by PECVD SiO2 • External Electronics based on National Instruments SCXI platform Lab View Interface • The array is scanned at a rate of 1000 Samples/sec (100 Samples/probe/sec) • Application to monitoring of plasma instabilities and spatiotemporal variation, J+(r,q,t), of ion flux in an inductively coupled Ar plasma is shown on the left t = 0 s t = 1.5 s t = 4.5 s t = 3.2 s

  4. On Wafer Ion Flux Measurements in a Cl2 Discharge in a Lam TCP 9400 Reactor • Goal: extend the measurements to a commercial reactor and realistic chemistry. • Challenging because of lack of ground reference and presence of rf bias. • Probe mounted on 8” Si wafer. • External electronics. • Ion current determined by measuring the voltage drop across a known resistance. • Both reference and measurement probe are isolated from ground (using a floating power supply.) • Shown on the left is the ion flux in Cl2 plasma • The ion flux increases as a function of exposure time to Cl2 plasma until it finally saturates. • Changes in chamber wall conditions is likely to be responsible for the drift. • Exposure to SF6 plasma resets the chamber back to reproducible condition. • Ion flux behavior as a function of time is reproducible. Measurement Probe (Biased @ -75V with respect to reference) Heavily Doped Si wafer (Reference)

  5. Relation Between the Ion Flux, Gas Phase Composition and Wall Deposits Ion Flux Cl & SiClx SiO2 on the Walls • Ion Flux monitored using ion flux probe. • SiClx and Cl concentrations monitored using optical emission. • Wall deposition monitored using the MTIR-FTIR probe. • Oxygen plasma oxidizes the surface of the wafer and probe. • Cl2 plasma (no bias power) etches the oxide layer slowly compared to the Si. • Drift in Ion Flux is due to changing wall conditions and plasma composition.

  6. Scale the single probe idea to an array of sensors on 8” wafers: 200 mm on-wafer ion flux sensors • 21 pads + 1 reference (heavily doped Si-wafer) on 200 mm wafer. • Printed circuit board (PCB) manufacturing methods were used to pattern the pads and the leads on the machined polyimid board. • Pads are nickel plated to reduce reaction with Cl2 plasma. • The leads from the pads are covered by a kapton mask. • The wafer, polyimide and the kapton stack is bonded together using vacuum epoxy • Heavily doped silicon region is exposed to the plasma and is etched.

  7. 200 mm on wafer ion flux sensors Kapton Insulation Mask Assembled Probe Array Polyimid Circuit Board

  8. Ion Flux Uniformity as a Function of Power in a Lam TCP Reactor • Ion flux uniformity was measured in a LAM TCP 9400 reactor to demonstrate the probe operation. • Operating condition; 50 sccm He, 30 mTorr. 100 W 200 W 300 W

  9. Summary • Designed and build 3” and 8” on-wafer ion flux probe arrays with external electronics and demonstrated their operation. • Completed preliminary experiments in a commercial reactor and demonstrated the effect of plasma composition and wall conditions on the ion flux. • Specific 2002 and 2003 Goals • Modify data acquisition to be used with rf bias on the electrostatic chuck. • Use the probe array to study the factors that affect the plasma and etching uniformity in Cl2/O2 etching of Si. • Specifically, the goal will be to understand the role of etching products, wall conditions, and the feed gas composition on ion flux uniformity. 2002 and 2003 Milestones Build and demonstrate 8” on-wafer ion flux probe array in industrial plasma etcher with external electronics by 9/30/2002. Integration of Si-based IC with sensor arrays. Characterize and test integrated MEMS ion sensor array. 9/30/2003.