1 / 20

Run Time, Mott-Schwinger, Systematics, Run plan

Run Time, Mott-Schwinger, Systematics, Run plan. David Bowman NPDGamma Collaboration Meeting 10/15/2010. Apparatus to measure A . Run Time Estimate: Number of Neutrons from guide. 1.46 10 11 N/sec at 1.4 MW. 89 days data to disk for LH and Al. Systematic Uncertainties.

brooklyn
Download Presentation

Run Time, Mott-Schwinger, Systematics, Run plan

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Run Time, Mott-Schwinger, Systematics, Run plan David Bowman NPDGamma Collaboration Meeting 10/15/2010

  2. Apparatus to measure A

  3. Run Time Estimate: Number of Neutrons from guide 1.46 1011 N/sec at 1.4 MW. 89 days data to disk for LH and Al

  4. Systematic Uncertainties Our policy has been to make systematic uncertainties < 1/10 of goal statistical uncertainty, 10-9

  5. Mott-Schwinger • Interaction of the neutron magnetic moment with the motional magnetic field of the target creates a spin-orbit interaction and a parity-allowed L-R analyzing power in elastic scattering.

  6. Strategy for Statistics and Systematics • All indications are that the apparatus will operate at neutron statistics • Measure n flux • Measure rate of detected gammas • Measure asymmetry uncertainty • Compare • Measure Al fraction in data • Compare with detector transport model

  7. Mott-Schwinger Neutron Elastic-Scattering Asymmetry. L-R mixes with U-D if the detector and the magnetic field are misaligned • LANL run gave L-R g Asymmetry = -1.9±2.0 10-7 • Gericke, Bowman, and Johnson published An,elastic =-41 10-6. • Ag,L-R~-20 10-7. • Contradiction! • Theory is wrong.

  8. Mott-Schwinger Analyzing Power • The new calculations used the method of phase shifts - plane-vanilla approach. • The MS spin-orbit interaction leads to a L-R asymmetry ~ 10-9 at 10 meV. • In addition to the M-S interaction, GBJ considered the n-p spin-orbit interaction. We made an error in transforming from the n-p system to the n-molecule system. • The L-R asymmetry from the corrected n-p spin-orbit force, 1 10-16, is negligible compared to the M-S asymmetry. Agrees with extrapolation from 10 MeV, A~ E3/2. (.01x10-9 3/2 = 3 10-16). • The L-R asymmetry in ~ 110-8 dominates, but is too small for us to measure.

  9. Aluminum neutron capture, g cascade, and b decay

  10. Yields from n+p−>d+g, prompt Al, and b-delayed Al g’s

  11. Prompt Al g’s • APV = -2±3 10-7 (measured in LANL run), 1.3 10-7 RMS (theory, Gericke et al.) • Estimate that 3% of the neutrons capture on Al and 15% of the prompt signal comes from Al • False asymmetry from prompt g ’s 2 10-8 . • We must measure this false asymmetry in Al runs and subtract from LH asymmetry. Optimal time fraction for Al runs is 15% and an additional 15% to improve LH statistics. • If the Al asymmetry is 2. 10-8 we aim for 5% fractional uncertainty in subtraction.

  12. What knowledge is required for correction? • Fraction of neutrons capture in Al and LH • Geometry differences for the Al in Al runs and Al in LH runs. • n-H scattering dominates transport in LH runs • Al runs: no neutrons capture on side walls • LH runs: many neutrons capture on side walls • We must apply Monte-Carlo corrections. We need experimental constraints.

  13. Detector g signal after beam offfrom LANL run 28 Al half life =2.32 min Most delayed g’s come from Al

  14. Strategy for subtracting b delayed background In situ measurement of pedestals reduces neutron rate by 12%. The pedestals come from electronic and b-delayed g signals. They depend on the irradiation history of the target.

  15. Strategy for Al prompt/delayed measurements • Interrupt beam and measure the decay of activated Al in Al runs. Determine the ratio of prompt to activation gammas. (Knowledge of the irradiation history is required.) Expect 7.7/1.8 • Interrupt beam in LH runs. Activation tail gives the amount of prompt Al signal in LH runs. • The Monte-Carlo model is needed to calculate the difference in between the LH and Al because the neutron transport changes

  16. Strategy for LH Running • Run-time estimate gives 89 days for production • LH data • Al data • Pedestals are included in LH and Al • Auxiliary runs are not included ~ 30 days (wag) • Prompt/Delayed gamma runs • Detector angle runs (A. source or B. neutrons) • Neutron flux and monitor calibration runs

  17. Scenario for b decay of 28Al g.s. • Polarized neutron captures on J=5/2 27Al and forms a compound-nuclear state. J=2 or 3. Pol ~ .30 • Cascade g’s carry away angular momentum and depolarize 28Al. g.s. Pol ~ .15 • 28Al g.s. lives for 139 sec before it b decays. The average polarization of neutrons is small 1/60/139 ~ 10-4. • Spin-lattice relaxation further depolarizes the 28Al g.s. • The b decay energy is inefficiently converted to g energy • Multiple scattering washes out the b direction.

  18. Delayed-neutron asymmetry reduction vs. spin-lattice relax. time

  19. Al bremsstrahlung asymmetry estimate Conclusion: Delayed asymmetry is negligible

  20. (Preliminary) Conclusions concerning systematic uncertainties • 90 days of data + 30 days for auxiliary experiments are needed for 10-8 uncertainty • Mott-Schwinger asymmetry is small and understood • The dominant source of systematic uncertainty is the subtraction of the prompt Al asymmetry • Observation of b delayed g‘s can constrain Al asymmetry

More Related