Jan '08 CKOVa moved to MICE Hall March '08 CKOVa and CKOVb installed MICE Hall

CKOV Update. Jan '08 CKOVa moved to MICE Hall March '08 CKOVa and CKOVb installed MICE Hall CAEN +HV and signal lines cabled Environemental sensors installed Checkout and First beam Summer '08 To Do Finish gas system EPICs displays (Daresbury) Awaiting muons

buck
Download Presentation

Jan '08 CKOVa moved to MICE Hall March '08 CKOVa and CKOVb installed MICE Hall

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CKOV Update • Jan '08 • CKOVa moved to MICE Hall • March '08 • CKOVa and CKOVb installed MICE Hall • CAEN +HV and signal lines cabled • Environemental sensors installed • Checkout and First beam • Summer '08 To Do • Finish gas system • EPICs displays (Daresbury) • Awaiting muons • Calibration and Simulation CM21 PID Session, Daresbury Lab , June 5, 2008 - CKOV Update, L. Cremaldi

  2. Mechanical Drawing Updates Schott glass Delrin window aerogel mirror Reflector rear cover CM21 PID Session, Daresbury Lab , June 5, 2008 - CKOV Update, L. Cremaldi

  3. Proud Father CM21 PID Session, Daresbury Lab , June 5, 2008 - CKOV Update, L. Cremaldi

  4. Reflector Panels and LED • Reflector Panels are made of tyvek material on foam board. • A single blue LED is placed at the center. Imperial Stand

  5. Environmental Sensors • Each CKOV has a temperature and humidity sensor with readback in the control room. • Daresbury Lab Epics panels are being prepared. Temperature/Humidity Sensors CM21 PID Session, Daresbury Lab , June 5, 2008 - CKOV Update, L. Cremaldi

  6. CKOVb R8 to MICE Hall

  7. Installed at MICE Hall (thanks William) ckovb ckova Oxford stand table bracket

  8. First pion - thanks JS. gva2 ckov-ch1 ckov-ch2 ckov-ch3 ckov-ch4 (not shown)

  9. CKOV Reconstruction ckovb muon pion ckova Digital Reco - Determine Prob(mu)-Prob(pi) by ON-OFF reco pattern per momentum region I, II, III. I. II. III. • Analogue Reco - Determine Prob(mu)-Prob(pi) by expected and seen light yields per momentum region I, II, III. • - PE(x,y) light map required. • - TOF0(x,y)/CKOV coincidence.

  10. G4-Beamline and Material Budget CM21 PID Session, Daresbury Lab , June 5, 2008 - CKOV Update, L. Cremaldi

  11. Summary • CKOV Installation went well. Many thanks! • CAEN +HV system from HERA?? K.Long • Drawings updated. Mike Reep • Finish dry gas system ASAP. • EPICs displays (w Daresbury). • Awaiting muons (PE calibrations). • Begin work on basic digital and analogue reco. • Update G4-Beamline with material budget. • Advanced G4 light simulations may not be necessary if data measurements taken? CM21 PID Session, Daresbury Lab , June 5, 2008 - CKOV Update, L. Cremaldi

More Related