300 likes | 839 Views
Next Generation Belimo Energy Valve. Belimo Energy Valve ™. The Energy Valve is a pressure independent control valve with an integrated BTU meter Measure Energy Control Power Manage Delta T. Belimo Energy Valve ™. BACnet. Actuator. Flow Sensor. Valve.
E N D
Next Generation Belimo Energy Valve Belimo Americas Danbury, Connecticut
Belimo Energy Valve™ The Energy Valve is a pressure independent control valve with an integrated BTU meter Measure Energy Control Power Manage Delta T Belimo Americas Danbury, Connecticut
Belimo Energy Valve™ BACnet Actuator Flow Sensor Valve Temperature Sensors (for supply & return water) Belimo Americas Danbury, Connecticut
Belimo Energy Valve™ Measure, Observe, Record and Trend Performance Data Measuring Flow and Delta T allows us to… Belimo Americas Danbury, Connecticut
Belimo Energy Valve™ Directly Control Flow or Energy Measuring Flow and Delta T allows us to… Belimo Americas Danbury, Connecticut
Belimo Energy Valve™ Power Saturation Point Limit Waste with Delta T Management Measuring Delta T allows us to… Belimo Americas Danbury, Connecticut
Benefits of using Energy Valve Belimo Americas Danbury, Connecticut
Benefits of using Energy ValveSimplified Control Controller Flow Rate Or Power Control Deliver exact flow to the coil or… Deliver exact load to the space Control Signal directly controls Flow or Energy Belimo Americas Danbury, Connecticut
Benefits of using Energy ValveSimplified Control DAT SWT Power Control can overcome disruptions in the supply water temperature Deliver exact BTU/hr to the space, regardless of system fluctuations. Belimo Americas Danbury, Connecticut
Benefits of using Energy ValveSave Energy Define delta T low limit with the Delta T Manager Higher Delta T means more efficient heat transfer… Use less water to create the same load. Belimo Americas Danbury, Connecticut
Benefits of using Energy ValveTrack Equipment Performance Access live or long term data for M & V, Ongoing Commissioning, or Predictive Maintenance Your system degrades over time… know about it before there is a comfort issue Belimo Americas Danbury, Connecticut
Benefits of using Energy ValveRecap Deliver exact GPM to the Coil or BTU/hrto the Space Define delta T low limits with the Delta T Manager Access live or long term data for M & V, Ongoing Commissioning, or Predictive Maintenance Simplified Control Save Energy Track Equipment Performance Belimo Americas Danbury, Connecticut
Belimo Energy Valve Does it really work? Belimo Americas Danbury, Connecticut
Case StudyMIT University - Boston, MA Hayden Library Building and Project Details 150,000 sq. ft. on 3 floors Built in 1947 (originally had its own dedicated chiller, later converted to campus district cooling) 6 AHU provide majority of the cooling Average delta T coil = 6.15oF Belimo Americas Danbury, Connecticut
Case StudyMIT University - Boston, MA Results • Aug 9 - Oct 9, 2010 DT = 6.15 F • Aug 9 - Oct 9, 2011 DT = 12.14 F Belimo Americas Danbury, Connecticut
Case StudyUniversity of Miami Hospital Building and Project Details • Rosenstiel Building • 11 AHUs • 2600 Tons of Cooling • Over 10,000 GPM • Delta T = 5.5F Belimo Americas Danbury, Connecticut
Case StudyUniversity of Miami Hospital Results • Delta T raised from 5.5F to 10.5F • Flow ~ 5600 GPM • Estimated $66,000/yr savings • Estimated 2.9 year payback Belimo Americas Danbury, Connecticut
Case StudyLarge Tech Company in North Carolina DT Management 96 GPM Flow Control 144 GPM Position Control 240 GPM Belimo Americas Danbury, Connecticut
Belimo Energy Valve™ Thank You Belimo Americas Danbury, Connecticut