120 likes | 218 Views
T1008 status. March 19, 2012 W.Baldini for the SuperB -IFR Group Presented by Aria Soha. R&D for the SuperB Instrumented Flux Return. Muon Identification E< 5GeV Superconducting solenoid F lux R eturn I nstrumented with active material
E N D
T1008 status March 19, 2012 W.Baldini for the SuperB-IFR Group Presented by Aria Soha
R&D for the SuperB Instrumented Flux Return • Muon Identification E< 5GeV • Superconducting solenoid Flux Return Instrumented with active material • Plastic scintillator bars readout through WLS fibers and Silicon Photo-Multipliers (SiPM) • Baseline layout to be tested on beam with a prototype • TDR to be written in spring…
The IFR Baseline Detection Technique • Magnet Flux Return instrumented to detect Muons and KL • BaBar-like detector with hexagonal barrel and two encaps • Plan to re-use BaBar IFR structure, adding iron to improve μ-ID • Scintillator as active material to cope with higher flux of particles • Minos-like scintillator bars readout through WLS fibers and Silicon Photo-Multipliers • 8-9 active • layers Endcap Barrel μ
The Prototype Iron Active Layers (Pizza Boxes) Prototype • Iron: 60x60x92 cm3, 9 slots for the active layers • up to 9 active layers readout together • 4 Time Readout (TDC-RO) “standard “ • 4 Binary Readout (BiRo) “standard” • 4 special modules to study different • fibers or SiPM geometry Active Layer (“pizza box”)
Summary of Activities • Installation: March 1-4 • ORC walkthrough: March 5, first beam: March 5 • Trigger timing and apparatus setting up • Data taking summary: • 8,6,5 GeV • Cherenkov scan • Muons: • Selected with Cherenkov (C1) • Selected with downstream scintillators (S3 and S4) • Pions • Selected with Cherenkov (C1) • Control triggers • No Cherenkov • Only Electrons (C2) veto • Still 16 hours of beam (until 6 am)
Cherenkov Scans • Fundamental importance to collect clean samples of muons and pions • very important to understand how well the Cherenkov tags the particles • Scan needed for each beam momentum: 8, 6, & 5 GeV/c
Cherenkov Pressure Scan: 8 GeV (N2) July-11 scan Pion peak Muon peak March-12 scan
Cherenkov Pressure Scan: 6 GeV (N2) July-11 scan March-12 scan
Cherenkov Pressure Scan: 5GeV March-12 scan
Event Samples… Hit channel time (samples of of 12.5 nsec) Detector hit map for a sample of Muons at 8 GeV
Event samples… Hit channel time (samples of of 12.5 nsec) Detector hit map for a sample of Pions at 8 GeV
Summary • Took data at 8, 6, & 5 GeV • Cherenkov seems to be more efficient at 6 and 5 GeV than in October • 24h (March 9th) running since Friday • Apart from a few interruptions at the beginning (March 6th) the beam was very stable • Took data until morning of March 14th then moved equipment out of the area