Megan Hartmann CHEM 4101 December 9 th , 2011

PFOA in Teflon Coated Cookware. Megan Hartmann CHEM 4101 December 9 th , 2011. PFOA and Teflon. Perfluorooctanoic Acid A carcinogen and toxicant Synthetic compound Molar Mass 414.07 g/ mol Typical amount found in cookware 4.3 ppb Teflon Chemically known as

Download Presentation

Megan Hartmann CHEM 4101 December 9 th , 2011

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PFOA in TeflonCoated Cookware Megan Hartmann CHEM 4101 December 9th, 2011

  2. PFOA and Teflon • Perfluorooctanoic Acid • A carcinogen and toxicant • Synthetic compound • Molar Mass • 414.07 g/mol • Typical amount found in cookware • 4.3 ppb • Teflon • Chemically known as polytetrafluoroethylene (PTFE) • Synthetic fluorocarbon polymer • Degrades around 260°C

  3. Background • PFOA is a surfactant used to attach PTFE into cookware making it non-stick. • PFOA is removed when cookware is cured, but residual amounts can remain • If the cookware is scratched or heated to high temperatures during cooking, the residual levels can be released into the air or the food being prepared.

  4. Hypothesis By using proper analytical techniques the residual PFOA that is released when Teflon coated cookware is heated to high temperatures can be measured.

  5. TechniquesConsidered

  6. Method of Choice: GC-MS Standards: PFOAfrom Sigma-Aldrich Order Number:171468 PFTE from Sigma-Aldrich Order Number:430935 Figure 1: Retrieved from http://www.chromacademy.com/resolver-november2010_Understanding_GCMS_part_1.asp

  7. Agilent 7000 GC/MS • High Selectivity • Fast Analysis (500 transitions per second) • Fluorinated compounds have different retention times Figure 2: Retrieved from Agilent Technologies. (2009). Agilent 7000B Triple Quadrupole GC/MS. [Brochure].

  8. Agilent 7000 ESI-Triple Quadrupole Mass Spectrometer • Signal to Noise Ratio of 500:1 for 100 femtograms • LOD- femtogram level • Operates at temperatures as high as 200°C • High selectivity Figure 3: Retrieved from Agilent Technologies. (2009). Agilent 7000B Triple Quadrupole GC/MS. [Brochure].

  9. Sample Prep • Empty Teflon coated cookware is heated up to varying temperatures • Specifically around 200-300°C • Smoke point of oils and where Teflon degrades • PFTE (Teflon) must be scraped off of cookware and made into a powder • Internal standards of PFOA and PFTE are added

  10. Expected Results Potentially harmful levels of PFOA will be found in Teflon coated cookware upon heating to high temperature Figure 4: Typical Quadrupole Mass Spectrum for PFOA Retrieved from Begley, T. "Perfluorochemicals: Potential sources of and migration from food packaging.”

  11. Conclusion To determine the safety of Teflon coated cookware GC/MS analysis can be used to measure the levels of residual perfluorooctanoic acid which are harmful to humans.

  12. References • Begley, T. "Perfluorochemicals: Potential sources of and migration from food packaging." Food additives and contaminants 22.10 (2005):1023.Guo, Zhishi, and X. Liu, and K. Krebs, “Perfluorocarboxylic Acid Content in 116 Articles of Commerce.” National Risk Management Research Laboratory, Environmental Protection Agency, 2009. • Huang, Ke, and KHuang. "Determination of trace PFOA in textiles with HPLC-UV spectrometry." 印染 37.9 (2011):37. • Kadar, H. "Comparative study of low- versus high-resolution liquid chromatography-mass spectrometric strategies for measuring perfluorinated contaminants in fish." Food additives & contaminants. Part A. Chemistry, analysis, control, exposure & risk assessment 28.9 (2011):1261. • King, Anthony. "Sticking point", Chemistry and Industry. 2007, 17, 24-25 • Lindstrom, Andrew, and A B BLindstrom. "Polyfluorinated Compounds: Past, Present, and Future." Environmental science & technology 45.19 (2011):7954. • Lv, Gang, GLV, andLv. "Determination of perfluorinated compounds in packaging materials and textiles using pressurized liquid extraction with gas chromatography-mass spectrometry." Analytical Sciences 25.3 (2009):425. • Skoog, Douglas A., F. James. Holler, and Stanley R. Crouch. Principles of Instrumental Analysis. 6th ed. Belmont, CA: Thomson Brooks/Cole, 2007. • Tracy, M., Liu, X., and Pohl, C. “Analysis of Perfluorooctane Sulfonate and Perfluorooctanoate in Water Samples Using Reversed-Phase Liquid Chromatography with Suppressed Coonductivity Detection.” Dionex Corporation. 2009. • Agilent Technologies. (2009). Agilent 7000B Triple Quadrupole GC/MS. [Brochure].