1 / 21

MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway!

MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway!. www.corinex.com. Corinex Enterprise Products Powerline Networking (Common Power Meter) Powerline Networking (Individual Power Meters) Coaxial Networking Coax and Powerline Networking (Common Power Meter).

ciro
Download Presentation

MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway!

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MDU Networking using CORINEX productsincluding the new 600 Mbps Corinex MDU Gateway! www.corinex.com

  2. Corinex Enterprise Products • Powerline Networking (Common Power Meter) • Powerline Networking (Individual Power Meters) • Coaxial Networking • Coax and Powerline Networking (Common Power Meter)

  3. MDU Networking – Product family • MDU Gateway creates a Powerline or Coaxial backbone • AV200 Enterprise Powerline • Ethernet Adapter CPE • AV200 Enterprise Powerline • Wall Mount CPE • AV200 Enterprise CableLAN CPE • 5+1 and 11+1 Phase Coupler (for bypassing Individual Meters) • Corinex High Pass and Mode Filters • Installation Training to teach hardware and software configuration CorinexAV200 Enterprise Powerline Ethernet Adapter CorinexAV200 Enterprise Powerline Wall Mount Corinex 5+1 Phase Coupler Corinex 11+1 Phase Coupler Powerline networking components CorinexMDU Gateway Powerline and Coax Corinex Installation Training CorinexAV200 Enterprise CableLAN Adapter Corinex High Pass Filter Corinex Mode Filters Coaxial networking components

  4. Corinex MDU Gateway MDU Gateway - Features • 3 AV200 200 Mbps Powerline Modules • 3 * 200 Mbps = 600 Mbps • Coaxial or Powerline input/outputs • Modules act as a Master / Head End • 2-34 MHz operation, 2-30MHz in EU (mode 6) • Optional Frequency Band segmenting using: • 2-12 MHz (mode 1) • 13-23 MHz (mode 2) • 24-34 MHz (mode 3) • Optional Built in Filters to support Frequency Band segmenting • Up to 32 users (CPE) per Module / 96 users per MDU Gateway (Coax or Common Power Meter in building) OR • Up to 11 electrical meters connected per Module / 33 per MDU Gateway (Individual Power Meters in building) • World’s ONLY enterprise MDU product! • World’s ONLY 600 Mbps product!

  5. MDU Gateway – Back Panel and Interfaces • Each Module has Coaxial and Powerline Input/Outputs • Within a single MDU Gateway a mix of Coax and Powerline input/outputs between modules is allowed • Example: • Module 1: Coax • Module 2: Powerline • Module 3: Powerline • or • Module 1: Coax • Module 2: Coax • Module 3: Powerline • or … • DO NOT use both Coax AND Powerline outputs on same module-interface Module 1 Powerline Input/Output Module 2 Powerline Input/Output Module 3 Powerline Input/Output Power On/OFF Module 1 Coax Input/Output Module 2 Coax Input/Output Module 3 Coax Input/Output Power Connection 10/100 BaseT

  6. Corinex Enterprise Products • Powerline Networking (Common Power Meter) • Powerline Networking (Individual Power Meters) • Coaxial Networking • Coax and Powerline Networking (Common Power Meter)

  7. M.Power Distrib. Panel Powerline Networking (Common Power Meter) Electrical Dist. Panel • Scenario 1: • (Hotels, Barracks, Residential) • 1 electrical phase per 2 floors • First 6 floors served by one transformer • Additional floors served by other transformer(s) • Same scenario for each phase serving different number of floors 6th Floor 5th Floor Phase 3 4th Floor 3rd Floor Phase 2 2nd Floor Phase 1 Pre Deployment Situation 1st Floor Main Power Meter

  8. Optical Fiber (or other broadband) Power Distribution Panel Power Distrib. Panel Powerline Networking (Common Power Meter) BROADBAND SIGNAL INJECTED IN POWERLINES Electrical Dist. Panel • Scenario 1: • Pure Powerline Networking: • Powerline Backbone (bypass meter) • Powerline within floor • 1 module for each of 3 phases • Direct Connection (no coupler) • AV200 Powerline CPE in each apartment/flat served • Up to 32 users per phase • 3 frequency bands (Mode 1,2,3 • for the 3 modules) Mode 1 Phase 3 6th Floor MDU Gateway Module 1 = Mode 1 Module 2 = Mode 2 Module 3 = Mode 3 Mode 1 5th Floor Mode 2 Phase 2 4th Floor Plug MDU Gateway into each electrical phase at 3 wall outlets of distribution panel Mode 2 3rd Floor Mode 3 Phase 1 2nd Floor Mode 3 1st Floor TIP: Mode 1 propagates furthest, then Mode 2, then Mode 3 MDU Gateway Main Power Meter Post Deployment Situation

  9. Corinex Enterprise Products • Powerline Networking (Common Power Meter) • Powerline Networking (Individual Power Meters) • Coaxial Networking • Coax and Powerline Networking (Common Power Meter)

  10. Powerline Networking (Individual Power Meters) • Scenario 2: • Residential Apartments/Flats: • Power Meters attenuate • Powerline signals by 5 to 45dB • MDU Gateway • Powerline Backbone • 5+1 / 11+1 Electrical • phase coupler • AV200 Powerline CPE In-Home • Full Frequency band (mode 6) Pre Deployment Situation

  11. Powerline Networking (Individual Power Meters) Corinex MDU Gateway Each Module-interface gives a 200 Mbps connection Ethernet 10/100 Base-T Module 1 Mode 6 Module 2 Mode 6 Module 3 Mode 6 Electrical Wire Electrical Wire Electrical Wire Use either 5+1 or 11+1 Phase Coupler on each module to connect up to 11 electrical meters per module-interface Corinex 11+1 Phase Coupler Corinex 5+1 Phase Coupler Corinex 11+1 Phase Coupler IN OUT IN OUT IN OUT Meter Meter Meter Meter Meter Meter Meter Meter Meter To individual Apartments / Flats with AV200 Powerline CPE for In-Home connectivity From Utility Power Feed Meter Meter Meter Up to 11 Power Meters Up to 11 Power Meters Up to 11 Power Meters Post Deployment Situation

  12. Corinex Enterprise Products • Powerline Networking (Common Power Meter) • Powerline Networking (Individual Power Meters) • Coaxial Networking • Coax and Powerline Networking (Common Power Meter)

  13. Coaxial Networking Continue to the next floor Apart 32 • Scenario 3: • (Hotels, Residential, Barracks) • 1 coax panel per floor • Additional floors on same coax line • ≤ 32 users per floor Apart 3 Apart 2 Apart 1 Apart 32 Apart 3 Apart 2 Apart 1 Coax Dist. Panel Apart 32 Apart 3 Apart 2 Apart 1 Main Cable Pre Deployment Situation Splitter

  14. Broadband Source Coaxial Networking Continue to the next floor • Scenario 3: • Pure Coax Networking: • Coax Backbone • All 3 Modules inject signal • Coax within floor • 1 Module (up to 32 users) • per Coax distribution panel • AV200 CableLAN CPE In-Home • 3 frequency bands (modes 1,2,3) • Add more segments to expand (add High Pass Filter and another MDU Gateway on 4th Floor connected via Ethernet) Mode 3 Apart 32 Apart 3 Apart 2 Apart 1 Corinex Mode 3 Filter Mode 1 Mode 2 Mode 3 Mode 2 Apart 32 Apart 3 Apart 2 Apart 1 Corinex Mode 2 Filter Mode 1 Mode 2 Mode 3 Coax Dist. Panel COAX BACKBONE Mode 1 Apart 32 Apart 3 Apart 2 Apart 1 Corinex Mode 1 Filter Mode 1 Mode 2 Mode 3 MDU Gateway Module 1 = Mode 1 Module 2 = Mode 2 Module 3 = Mode 3 3 way Splitter Splitter Main Cable Post Deployment Situation

  15. Broadband Source Coaxial Networking – Creating the Coaxial Backbone Continue to the next floor Coax Dist. Panel Coaxial Backbone Injection Unit Options Mode 6 COAX BACKBONE OPTION 2: Corinex AV200 Enterprise CableLAN OPTION 1: Corinex Head End Mode 6 Main Cable Splitter OPTION 3: MDU Gateway Mode 6 OPTION 3: MDU Gateway

  16. Coaxial Networking Continue to the next floor Apart 32 • Scenario 4: • (Hotels, Residential, Barracks) • 1 coax panel per floor • Additional floors on same coax line • > 32 users per floor Apart 3 Apart 2 Apart 1 Apart 32 Apart 3 Apart 2 Apart 1 Coax Dist. Panel Apart 32 Apart 3 Apart 2 Apart 1 Main Cable Splitter Pre Deployment Situation

  17. Apart 64 Apart 64 Apart 64 Apart 4 Apart 4 Apart 4 Apart 3 Apart 3 Apart 3 Apart 2 Apart 2 Apart 2 Apart 1 Apart 1 Apart 1 Coaxial Networking Continue to the next floor • Scenario 4: • MDU Networking Solution • Coax Backbone • 1 Module to carry input • Coax within floor • 1-2 Modules for each coax distribution panel (up to • 64 users) • AV200 CableLAN CPE In-Home • Full Frequency band on • Backbone (mode 6), • Full Frequency band on floor • (≤ 32 users) or Partial • frequency band on floor • (> 32 users, mode 1/2) Mode 6 or Mode 1/2 Mode 6 Coaxial Distribution Panel Mode 6 Mode 6 or Mode 1/2 COAX BACKBONE Coaxial Distribution Panel Mode 6 MDU Gateway Mode 6 or Mode 1/2 Splitter Coaxial Distribution Panel Coax Backbone Post Deployment Situation Corinex High Pass Filter Splitter Splitter

  18. Corinex Enterprise Products • Powerline Networking (Common Power Meter) • Powerline Networking (Individual Power Meters) • Coaxial Networking • Coax and Powerline Networking (Common Power Meter)

  19. Apart 32 Apart 32 Apart 32 Apart 4 Apart 4 Apart 4 Apart 3 Apart 3 Apart 3 Apart 2 Apart 2 Apart 2 Apart 1 Apart 1 Apart 1 Coax and Powerline Networking (Common Power Meter) Continue to the next floor • Scenario 5: • Coaxial / Powerline Hybrid • Coax Backbone • 1 Input Module • Powerline within floor • 1 Module for each electrical panel = 32 users per panel • Direct Coupling to Power – No Electrician Required • AV200 Powerline CPE In-Home • Full Frequency band (mode 6) on backbone and floor Plug directly (any Electrical Phase) Electrical Subpanel Mode 6 Mode 6 Plug directly (any Electrical Phase) Electrical Subpanel Mode 6 COAX BACKBONE Mode 6 Plug directly (any Electrical Phase) Electrical Subpanel Mode 6 MDU Gateway Coax Backbone Post Deployment Situation Splitter

  20. Apart 64 Apart 64 Apart 4 Apart 4 Apart 3 Apart 3 Apart 2 Apart 2 Apart 1 Apart 1 Coax and Powerline Networking (Common Power Meter) • Scenario 6: • Coaxial/Powerline Hybrid • Coax Backbone • 1 Input Module • Powerline within floor • 2 Modules for each electrical panel = 64 users per panel • Direct Coupling to Power – No Electrician Required • AV200 Powerline CPE In-Home • Full Frequency band on Backbone (mode 6), Segmented Frequency band on floors (modes 1,2,3) Continue to the next floor Apart 64 Mode 3 Electrical Subpanel Apart 4 Apart 3 Mode 2 Apart 2 Apart 1 Mode 1 Electrical Subpanel Mode 6 Mode 3 Mode 2 Mode 6 Electrical Subpanel COAX BACKBONE Mode 1 Post Deployment Situation MDU Gateway Coax Backbone Splitter

  21. MDU Networking – Summary • Corinex MDU Networking Products: • Allow you to network an entire building regardless of size or shape or metering • Allow you to network an entire building without adding any additional wiring • Offer the highest performance MDU Networking available • Corinex increases buildings property owners investment value • Corinex MDU solution guarantees you very quick ROI and investment protection as the broadband network becomes part of your intelligent building property. • Corinex MDU Gateway is the only product of its kind in the industry – 600Mbps! • MDU Broadband equipment revenues will triple in the next 4 years – The Corinex MDU Gateway allows you to win your share!

More Related