An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. P 505 Statistical Determination of Insulator Performance at Koeberg Insulator Pollution Test Station Presented by Dr WL Vosloo (Eskom) Dr I Gutman (STRI) Dr JP Holtzhausen (University of Stellenbosch)

  2. Typical Performance Data at KIPTS Electrical Performance with Natural Pollution Natural Ageing Performance Note: E-1 and F are the reference insulators at KIPTS and was not chosen as the optimum solution for this area.

  3. Statistical Approach • Pollution stress at site: probability density function f(g) • Probability for flashover at maximum operating voltage: cumulative distribution function P(g) • Multiplication of f(g) and P(g) – the area under this curve defines the risk for flashover

  4. Pollution stress at site:probability density function f(g) I U Measured on Insulator at KIPTS

  5. Probability for flashover at maximum operating voltage:cumulative distribution function P(g) NCI totally Hydrophilic Measured on Insulator at KIPTS

  6. Calculated Number of Flashovers per Insulator per year

  7. Determine What Insulation to Use

  8. Predict In Service Insulation Performance

  9. Future Work • Further investigate the use of leakage current data measured on all insulators tested at KIPTS so as to determine there statistical performance curves • Determine statistical performance curves for various standard insulators in the laboratory (ac and dc) • Establish a methodology where both sets of data can be used so as to help Eskom select insulators for the power network