An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. INTAKE NOISE SUPPRESSOR INSTALLATION MANUAL

  2. PARTS LIST PART NUMBER DESCRIPTION QUANTITY PICTURE 1” STREET L 2 FITTING029 FITTING034 1” NPT PLUG (OPTIONAL) 1 FITTING082 1” NPT MALE X 1” BARBED 4 FITTING024 ¾” NPT NIPPLE 1 1/8” LONG (OPTIONAL) 2 FITTING041 ½” NPT NIPPLE 1 3/8” LONG (OPTIONAL) 2 FITTING090 1” NPT X ½” NPT REDUCER (OPTIONAL) 2 FITTING091 1” NPT X ¾” NPT REDUCER (OPTIONAL) 2 HOSE002 1” I.D. BLACK VENT HOSE 12 FT. SILENSOR001 INTAKE NOISE SUPRESSOR 1

  3. Installation Instructions 1.Remove existing filter assembly/assemblies from compressor pump 2.Install FITTING029 (1” Street L) into head intake port tighten until elbow is facing down. Install FITTING082 (barbed connector) into FITTING029 and tighten. NOTE: Standard Intake Port size is 1”, however some pumps may have ½” or ¾” port sizes. Additional fittings have been supplied to reduce from 1” to ½” or ¾” if necessary. Additional components are marked (OPTIONAL) on Parts List. FITTING029 FITTING082

  4. 3.Install FITTING082 as shown and tighten. NOTE: Example shown below requires only one outlet due to a single pump filter application. The 2nd Inlet Port has been plugged using FITTING034 (1” NPT PLUG). FITTING034 (OPTIONAL) FITTING082

  5. 4.Place Silencer in desired location (recommend just to the left of the unit). Trim HOSE002 to desired length and slip over FITTING082 BARBED CONNECTOR. HOSE002

  6. 5.To access and replace Silencer Filter Elements: a.Remove thumb screws from front of Silencer b.Remove Silencer Assess Panel c.Remove filter wing nuts d.Remove filter covers e.Remove filter elements WING NUT FILTER COVER FILTER ELEMENT THUMB SCREW ACCESS PANNEL