120 likes | 210 Views
Some thoughts on Tracking System for Stage 1 HPS. Simon Kwan Fermilab 09/19/2011. Krzysztof Piotrzkowski July 2011. Design Considerations. Based on the last three slides, we make the following assumptions Ready for installation in 2013/2014 Four stations (2x2) at 240 m from IP5
E N D
Some thoughts on Tracking System for Stage 1 HPS Simon Kwan Fermilab 09/19/2011
Design Considerations • Based on the last three slides, we make the following assumptions • Ready for installation in 2013/2014 • Four stations (2x2) at 240 m from IP5 • Each station has 4 pixel planes covering roughly 1cm x 3 cm • Resolution per plane ~50 mm (??) • Would like to avoid large dead area near pocket window • Use as much as possible parts from CMS pixel detector (sensor, ROC, optical links, DAQ etc) • Use ~300m long optical fibers for signal/trigger/control transmission to/from CMS DAQ • High and potential high fluence up to 1015 p/cm2/year (please confirm) • Detector sitting in its own box and not in secondary vacuum • If any of the above are not valid, please sing out loud
Other important considerations • Tracking group too small; needs help on getting resources (money, expertise) • R&D activities focused more on 3d sensors which would not be ready for 2013/2014 • Not difficult to come up with a design for the Technical Proposal but will there be interest amongst the collaborating groups to build such a system • Stage II system will be very different (diversion of effort both in building and operating it) • Rather limited physics reach • Little synergy with CMS pixel upgrade • CMS Pixel upgrade now plans to have a pilot system ready for 2014 (manpower, diversion of effort ……). Possible to combine effort with FP240 Tracker???
Pixel Modules (contd) • Alternatively, we still have about 14 good sensor wafers that we could use (each wafer has two 2x3s and two 2x4s) • Still has a number of the PSI46v2 ROC wafers and enough tested good VHDIs ~ 14 2x4s and 10 2x3s) • Question is of course on bump bonding and re-start the plaquette production (time, money, resources etc but do-able)
CMS Pixel Modules • A 2x3 or 2x4 CMS FPIX plaquette could be used for the plane • Inventory: Breakdown below 500V and more than 1% bad pixels per ROC -> acceptable? About 6-8 each of the grade B 2x3 and 2x4s are not available any more (used in the Fermilab MTEST pixel telescope)
Station Design • Each plane could be tilted at 30 degree or more to minimize the dead area near the pocket wall • Pixel size is 100x150 um and if resolution required is 50um, don’t need x-measuring and y-measuring plane • It can be mounted on a carbon fiber with excellent thermal conductivity. All planes will be sitting on a metal base plate with cooling lines inserted. • Cooling can be implemented (may really be needed if the fluence is as high as claimed) • Each plane will be connected by a short flat cable to a PCB which serves a pair of station. One TBM will be located on the PCB to orchestrate the readout. • Power and signal/control will be provided to the ROCs through this PCB • Need to design the PCB (Station readout card) and the cable (pigtail) • Pigtail is about 60-70 cm long
Station readout • Pigtails will connect to a port card. • Two pigtails per station • The two stations on the same arm will be readout by the same port card • Port card will house one Analog optohybrid ( 6 channels) and one DOH (for the ROC settings). It will also has the gatekeeper, delay25, TPLL etc. Pretty much like the current Port card for FPIX but needs a different yet simple redesign • From the port card, long optical fibers will carry signal to/from the central CMS DAQ • While details still have to be worked out, the proposed conceptual design should work and would need only minimal change to the DAQ and DCS software.