1 / 5

FIRELEC Migration Solution

FIRELEC Migration Solution. Don't let wiring costs prevent you from upgrading a PROVOX 20 series system to a DeltaV system. This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.

Download Presentation

FIRELEC Migration Solution

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FIRELEC Migration Solution Don't let wiringcostspreventyoufromupgrading a PROVOX 20 series system to a DeltaV system This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.

  2. Provox 20 series > DeltaVUsing PIA (Provox Interface Adapter) I/O cardto be removed New DeltaV System I/O panel and cable to be kept • The Provox Interface Adapter (PIA) allows to connect easily, an existing Provox Termination Panel to a DeltaV I/O card keeping : • the existing I/O panel • the existing associated I/O cable

  3. Primary Provox Highway Secondary Provox Highway SR90 or SRx Controller I/O Termination panel I/O Termination panel I/O panels and I/O cables stay in place in the existing cabinets Process I/Os stay in place in the existing cable trays I/O Termination panel Hardware to beremoved Provox Highway to be removed SR90 or SRx Controller to be removed CP6701 Power supply and Communication Cards to be removed 1 - 14 I/O cards 20 series to be removed I/O Files (CP6701) are kept Process I/Os

  4. Primary DeltaV Highway The new DeltaV architecture is installed Secondary DeltaV Highway I/O3 I/O6 I/O7 I/O1 I/O5 I/O8 I/O2 I/O4 PS Cntrl The new FIRELEC I/O cables are installed between PIAs and DeltaV I/O cards The I/O files are kept and used for the installation of the PIAs No active component is kept in the existing file I/O Termination panel I/O Termination panel I/O Termination panel Hardware to beinstalled CP6701 The new PIAs are installed in the existing I/O Files (CP6701) Process I/Os

  5. Advantages • The main advantages of the PIAs • for PROVOX migration are as follow : • Existing I/O cables are just disconnected from the Provox I/O cardsand reconnected to the PIA without any change at the same place • (same terminals with same labelling and same electrical features) • The existing loop drawings are kept without any modification, • allowing all maintenance processes and procedures • to remain unchanged.