100 likes | 115 Views
Don't let wiring costs prevent you from upgrading your Provox™ 20 series system to an Experion C300™ system. Explore two solutions available for a seamless migration process to optimize your system efficiently.
E N D
FIRELEC Migration Solution Don't let wiringcostspreventyoufromupgrading a PROVOX™ 20 series system to an EXPERION C300™ system This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.
PROVOX™ 20 series > EXPERION C300™ • Two solutions available : Solution N°1 : FMS-PVXCL-EXP-1 • Removing I/O panels • Removingassociated I/O cables • Removing I/O files CP6701 • Replacingexisting PROVOX™ I/O panels by new FIRELEC IOPs (Input Output Panels) Solution N°2 :FMS-PVXCL-EXP-2 • Keepingexisting I/O panels • Keepingassociated I/O cables • Keeping I/O files CP6701 and removing communications and I/O cards • InstallingPIAs (PROVOX™ Interface Adapters) in the existing CP6701 I/O files
PROVOX™ 20 series > EXPERION C300™UsingIOPs • No existing PROVOX™ hardware is kept(I/O File – I/O card – I/O panel – I/O cable) • Existing PROVOX™ I/O panels are replaced by new IOPs which are electrically and mechanically fully compatible • Existing wiring is kept in place • Time for Hardware migration from an old toward a new I/O panel : about 30mn per panel I/O card and I/O panel to be removed
Primary PROVOX™ Highway Secondary PROVOX™ Highway SR90 or SRx Controller I/O Termination panel I/O Termination panel I/O Termination panel Process I/Os stay in place in the existing cable trays Hardware to beremoved PROVOX™ Highway to be removed SR90 or SRx Controller to be removed CP6701 Power supply and Communication Cards to be removed 1 - 14 I/O cards 20 series to be removed I/O cables to be removed I/O panels to be removed Process I/Os
Primary EXPERION C300™ Highway Secondary EXPERION C300™ Highway The new EXPERION C300™ architecture is installed I/O3 I/O6 I/O7 I/O1 I/O5 I/O8 I/O2 I/O4 PS Cntrl The new FIRELEC I/O cables are installed between IOPs and EXPERION C300™ I/O cards The new IOPs are installed using the existing mechanical structure of the cabinets(30 mn per panel) Hardware to beinstalled New I/O panel New I/O panel New I/O panel Process I/Os
Advantages • The main advantages of the IOPs • for PROVOX migration are as follow : • Existing wiring is just disconnected and reconnected • without any change at the same place • (same terminals with same labelling and same electrical features) • The existing loop drawings are kept without any modification, • allowing all maintenance processes and procedures • to remain unchanged.
PROVOX™ 20 series > EXPERION C300™Using PIA (PROVOX™ Interface Adapter) I/O cardto be removed New EXPERION C300™ System I/O panel and cable to be kept • The PROVOX™ Interface Adapter (PIA) allows to connect easily, an existing PROVOX™ Termination Panel to a EXPERION C300™ I/O card keeping : • the existing I/O panel • the existing associated I/O cable
Primary PROVOX™ Highway Secondary PROVOX™ Highway SR90 or SRx Controller I/O Termination panel I/O Termination panel I/O panels and I/O cables stay in place in the existing cabinets Process I/Os stay in place in the existing cable trays I/O Termination panel Hardware to beremoved PROVOX™ Highway to be removed SR90 or SRx Controller to be removed CP6701 Power supply and Communication Cards to be removed 1 - 14 I/O cards 20 series to be removed I/O Files (CP6701) are kept Process I/Os
The new EXPERION C300™ architecture is installed I/O3 I/O6 I/O7 I/O1 I/O5 I/O8 I/O2 I/O4 PS Cntrl The new FIRELEC I/O cables are installed between PIAs and EXPERION C300™ I/O cards The I/O files are kept and used for the installation of the PIAs No active component is kept in the existing file I/O Termination panel I/O Termination panel I/O Termination panel Hardware to beinstalled Primary EXPERION C300™ Highway Secondary EXPERION C300™ Highway CP6701 The new PIAs are installed in the existing I/O Files (CP6701) Process I/Os
Advantages • The main advantages of the PIAs • for PROVOX migration are as follow : • Existing I/O cables are just disconnected from the PROVOX™ I/O cardsand reconnected to the PIA without any change at the same place • (same electrical features) • The existing loop drawings are kept without any modification, • allowing all maintenance processes and procedures • to remain unchanged.