New in 2007 edition and in a-2008. 2.7.5.2.1 MRL Pit Signage 3.18.6 Marking of HY Jack 8.10.2.2.2 Governor 8.10.4.1 Escalator Governor 8.11 Requirements moved to 8.6 (‘08) 8.9.2 Added Esc. Code Data Plate Others in Parts 5, 6 and 7 Also changes for those enforcing NBCC (Canada).
E N D
New in 2007 edition and in a-2008 • 2.7.5.2.1 MRL Pit Signage • 3.18.6 Marking of HY Jack • 8.10.2.2.2 Governor • 8.10.4.1 Escalator Governor • 8.11 Requirements moved to 8.6 (‘08) • 8.9.2 Added Esc. Code Data Plate • Others in Parts 5, 6 and 7 • Also changes for those enforcing NBCC (Canada) CodeDataPlate.com
Violations • A17.1-2000 and later editions Part 8 • A17.3-1996 and later editions CodeDataPlate.com
Data Plates • A17.1 Requirements • Counterweight Runby Data Plate • Crosshead Data Plate • Capacity Plate • Safety Marking Plate • Jack Marking Plate • Rail Lube Plate • Governor Marking Plate • Brake Marking Plates • Buffer Marking Plate CodeDataPlate.com
More Data Plates • A17.1 Requirements (Continued) • Plunger Gripper Marking Plate • Hydraulic Machine & Valve Data Plates • Escalator/Moving Walk Brake Data Plates • Chain Data Plates (Dumbwaiter) • Rack & Pinion Data Plate • Code Data Plate • A17.3 Requirements • Rail Lube Plate • Capacity Plate CodeDataPlate.com
Tags • A17.1 Tags • Governor Rope Tag • Hoist Rope Data Tag • Acceptance Safety Test Tag • Resocketing Tag • Escalator Governor • Periodic Test Tags • A17.3 Tags • Hoist Rope Data Tag • Chain Data Tag CodeDataPlate.com
Signs • A17.1 Signs • Bottom Car Clearances • Refuge Space on Top of Car Enclosure • Working Areas in the Car or on the Car Top • Working Areas in the Pit • Location of Equipment - Governor Servicing • Freight Car Signage • Anti-creep Operation • Fire Service Signage CodeDataPlate.com
More Signs • A17.1 Signs (Continued) • Emergency Brake Sign • No Jumper Sign adjacent to Bypass Switches • Escalator & Moving Walk Caution Signs • Additional (Esc. & M.W.) Signs • A17.3 Signs • Freight Car Signs • Escalator Caution Signs • D/W “No Riders” Signs CodeDataPlate.com
2.4.5 Counterweight Runby Data Plate CodeDataPlate.com
2.6.5.2 (<‘04) or 2.7.9.2 (’S-05>) CodeDataPlate.com
2.13.4.2.4 Door Operator Plate Instructions Provided CodeDataPlate.com
Under b-1995 and earlier 2.16.3.2.2 and3.16.3 Hydro Under 1996 and later Traction A17.1 Req. 8.6.1.6.7 only not in A17.3 CodeDataPlate.com
Jack, Safety Plank & Capacity Marking of Hydraulic Jack The exposed portion of each hydraulic jack after installation shall be plainly marked in a permanent manner with the following: (a) the name or trademark by which the organization that manufactured the hydraulic jack can be identified (b) the manufacturer’s designation of the type or model (c) year of manufacture Marking Plates for Safeties A metal plate shall be securely attached to each safety so as to be readily visible, and shall be marked in a legible and permanent manner with letters and figures not less than 6 mm (0.25 in.) in height indicating: (a) the type of safety, based on 2.17.5 (b) the maximum tripping speed in m/s (ft/min) for which the safety is permitted (c) the maximum weight in kg (lb), that the safety is designed and installed to stop and sustain (d) the force in N (lbf) required to activate the safety or rope releasing carrier, if provided (e) the manufacturer’s name or trademark (07) Hydraulic (3.18.6) Traction (2.17.14) CodeDataPlate.com
Other Hydraulic Markings CodeDataPlate.com
Safety Test Tag CodeDataPlate.com
Pull-thru +Buffer+Flex Hose Test Tag CodeDataPlate.com
For Roller Guides A17.1 - 2.17.16 & A17.3 - 3.5.6 For Slide Guides In A17.1-2000 and later editions this information must be on Crosshead Data Plate CodeDataPlate.com
2.18.9 - Governor Plate CodeDataPlate.com
2.19.3.3 2.24.8.5 Brakes Plates The emergency brake shall be provided with a marking plate indicating the range of total masses (car with attach- ments and its load) for which it is permitted to be used, the range of speeds at which it is set to operate, and the criteria such as rail lubrication requirements that are critical to the performance. CodeDataPlate.com
Buffer Marking Plates 8 items 2.22.3.3 2.22.2.3 and 2.22.4.11 (for Oil Buffers) CodeDataPlate.com
Machine Room Brake Plates Governor Plate Code Data Plate Ambient Air Plate Hydro Data Plates Warning Signs Fire Service Signs Hoistway and Pit Crosshead Data Plate Rail Lube Instructions Warning Signs Safety Plank Plate Buffer Plate Counterweight Runby Freight & Capacity 8.6.1.6.7 Check for any Missing or Damaged Signs and Data Plates CodeDataPlate.com
Acceptance Tests 8.10 Requirements New Installations Alterations Periodic 8.11 Requirements 8.11.1.6 Tag New under b-2008: Testing moves to 8.6 Inspection Tags CodeDataPlate.com
TN 02-3392 CodeDataPlate.com
TN 02-3392 CodeDataPlate.com
Code Data Plates • 8.9.1 Required Information • 8.10.1.2 Applicability of Inspection and Test Requirements • 8.9.2 Location • Mainline or on Controller • Additional Plate for External Escalator Inspections • 8.9.3 Material and Construction • ...shall remain permanently and readily legible. (07) CodeDataPlate.com
SECTION 8.9 Requirement 8.9 contains requirements for all new and existing equipment within the Scope of this Code. 8.9.1 Required Information Data plate shall be provided and maintained that shall indicate the Code to be used forinspections and tests (see 8.10.1.2). The data plate shall indicate the Code and edition in effect at the time of installation. The data plate shall also indicate the Code in effect at the time of any alteration and indicate the applicable requirements of 8.7. CodeDataPlate.com
Installation Code Edition • Original Installation Date • Elevator Permit Date • Other Dates If Unknown • Original Installation Code • Follows AHJ’s Effective Dates • Use ASME Effective Dates • AHJ has no dates • No AHJ • GSA • Format is the same as in Inspector’s Guide CodeDataPlate.com
Equipment Without Alteration • Older Installations • Use applicable adopted A-17.1 editions • Use locally adopted code/standards such as: • Adopted A17.3- Edition • California CA Title 8 - Group 2 • Ohio Bulletin 110 (Red Book) • Iowa 875-IAC Ch. 73 • Massachusetts 524 CMR • Missouri 11 CSR 40-5.065 • Pennsylvania PA 34 Ch. 7 • Washington WAC 296-96 Min. Std. • Use building code referenced A17.1 edition • New Installations • Use applicable ASME edition as AHJ adopts CodeDataPlate.com
Edition Sensitive Items(85 years of code) • A17.3 applies from d-1986 through d-2000 to Part XII • Item 1.6 Car Emergency Signal there are 6 differences • Space Guards A17.1-1937 and later editions (also A17.3) • Static Control a-1988 and later editions • Glazing b-1989 and later editions & again in a-2005 • Item 1.12/13 & 3.8 (Cab items) there are 16 differences • and 16 more relating to car & hoistway doors & gates • Door Restrictors b-1980, b-1983 and b-1989 differences • Hydro RPR required for installations under c-1986 and later • Fire Service b-1973, 1981, 1984, b-1989, 2000 and 2004 CodeDataPlate.com
CDP Flow Chart CodeDataPlate.com
Job Information Web, e-mail, phone or fax
CodeDataPlateOrderForm CodeDataPlate.com
Common Errors - Disconnect • Change in Power Supply = 8.7.2.27.3 or 8.7.3.31.4 • Change of Voltage, Frequency or Number of Phases • Change from DC to AC • Change of combination of DC and AC • Replace Wiring or Disconnect = 8.7.2.8 or 8.7.3.8 • Includes new machine room wiring, hoistway wiring and travelling cables • Requires conformance with Section 2.8 which includes reference to NFPA 70 (NEC) CodeDataPlate.com
Common Errors - Control 8.7.2.27 • Install like Controller = 8.7.2.27.4 or 8.7.3.31.5 • Change of Motion Ctrl. = 8.7.2.27.5 or 8.7.3.31.6 • Change in Operation = 8.7.2.27.6 or 8.7.3.31.7 • Related requirements • Top of Car Inspection = 8.7.2.27.1 or 8.7.3.31.1 • Leveling = 8.7.2.27.2 or 8.7.3.31.2 • Anti-creep = 8.7.3.31.3 • Stop Switch = 8.7.2.27.7 (was 8.7.2.14.5 in a-2002 and earlier) • Alter an EPD = 8.7.2.27.8 or 8.7.3.31.11 (‘07) CodeDataPlate.com
Common Errors - Jack 8.7.3.23 • Replace Jack with new Jack = 8.7.3.23.1 • Cut off head and weld onto new Cylinder, re-use the plunger = 8.7.3.23.3 • Related requirements • Plunger only = 8.7.3.23.2 • Change of Working Pressure = 8.7.3.23.4 • Relocation of Jack = 8.7.3.23.5 • Relocation of Tank = 8.7.3.23.6 • Plunger Gripper = 8.7.3.23.7 CodeDataPlate.com
Custom Software CodeDataPlate.com
Custom Software CodeDataPlate.com
Custom Plates • Alterations Under A17.1-1996 Edition • Alterations Under A17.1-2000 Edition CodeDataPlate.com
Alteration Plate Door Operator Plunger Gripper Wiring Valve Re-opening Devise Tank Door Restrictor Limits Controller Replacement Top of Car Insp.. Emergency Operations Leveling CodeDataPlate.com
Field Marked Alteration PlateCovers Common Minor Alterations Re-opening Devise Rope Brake Door Restrictor Jack Replacement Emergency Lowering Cylinder Only HY Fire Service Alterations TR Cab Interiors Instructions Provided Valve Alteration CodeDataPlate.com
Code Data Plate Kits CodeDataPlate.com
Thank You - Questions CodeDataPlate.com