Electrical Engineering session - summary

Electrical Engineering session - summary. Bozhidar : 13kA EE systems Installation of s nubber capacitors in RQD/F EE systems New arc chambers for RQD/F EE switches All d ump resistors re-configuration RB dump resistors (DQRB) mechanical modification throughout

Download Presentation

Electrical Engineering session - summary

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Electrical Engineering session- summary • Bozhidar: 13kA EE systems • Installation of snubber capacitors in RQD/F EEsystems • New arc chambers for RQD/F EE switches • All dump resistors re-configuration • RB dump resistors (DQRB) • mechanical modification throughout • thermostat replacementinRR73 and RR77 • 4 water cooling stations relocationin P1 and P5 • Power switching relay (230V/8V) of holding coil(RL4,6,8,10 in BCMs) • Water cooled cable exchange 13kA EE systems • P4 right RB, RQD/F • P6 left & right RB, RQD/F • P8 left & right RB, RQD/F • General maintenance of all 13kA EE systems • IST • SCT • HWC TE-MPE LS1 Workshop, Knud, Edward,23-Nov-2012

  2. Electrical Engineering session- summary • Gert: 600A EE systems • Loosening of holding coil mechanism • Micro-switch not actuated • Main axle fixation • Improvement of existing Voltage Measurement Channel • Replacement of Voltage Divider by low impedance divider and noise reduction components • Replacement of Measurement Board by low noise separation amplifier • Replacement of DQAMS by 12 bit to 24 bit ADC • Voltage measurement taps to be improved • Hi-level SW for on-line analysis • Installation of Thermostats • Reprogramming of Firmware in all 404 interface cards • Visual inspection of main axles – Endoscope • IST • SCT • HWC TE-MPE LS1 Workshop, Knud, Edward, 23-Nov-2012

  3. Electrical Engineering session- summary • Gert: Cabling activities • Securing cables and cable-ends • Installation of new instrumentation cables on the IPQs Q8, Q9 and Q10 • Extension/replacement of cables connected to the DYPB and DYPQ racks TE-MPE LS1 Workshop, Knud, Edward, 23-Nov-2012

  4. Electrical Engineering session- summary Questions / Answers / Open points • Bozhidar: 13kA EE systems • Rudiger: Can we speed up the cool down of the dump resistors from 2h to 1h? • Gert: 600A EE systems • Rudiger: Is „Opening time measurement” needed in the tunnel? Gert: Yes, after such a big intervention on the breakers. • Reiner: DQAMS can be delivered after LS1 because it is not a critical issue. • Edward: Is it needed to put signals from thermostat mounted on the equalizing resistor to the interlock? Monitoring/threshold? • Gert: Cablingactivities • Gert: Has sent a proposal to EN/EL concerning the production of the required cables – no answer. • Knud: No „spaghetti” cables after LS1. • Andrzej: Why have the missing cables not been measured/produced yet? TE-MPE LS1 Workshop, Knud, Edward, 23-Nov-2012