1 / 8

Tau study updates (A pol etc.)

Tau study updates (A pol etc.). Taikan Suehara. e+e- →τ+τ-. TaJet vs. Durham-ycut. Compare original tau jet finder (TaJet) with “durhamycut” in Satoru jet finder (durhamycut is the only non-njet-fixed jet finder in SatoruJet except “manual” tuning mode)

dwight
Download Presentation

Tau study updates (A pol etc.)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Tau study updates(Apol etc.) Taikan Suehara

  2. e+e- →τ+τ-

  3. TaJet vs. Durham-ycut • Compare original tau jet finder (TaJet)with “durhamycut” in Satoru jet finder(durhamycut is the only non-njet-fixed jet finder in SatoruJet except “manual” tuning mode) • TaJet gives the bestperformance inenergy estimationof tau-missing • Despite many aspectsto be improved,I adopt TaJet for current analyses.

  4. Pol. analysis using t->pn channel • glddec07 tautau500 data (12500 events) • 1432 t+ and 1429 t- events (11.4%)(selected by MC info) • 2246 1+1 jet events (8.98%) by TaJet→ recorded into root file for analysis • MC/Reco p 4-momentum is converted to t rest frame using MC t info • MC/Reco direction is origined by t flying direction • Check angular information

  5. cosq (t) (same as last week)

  6. Angular distribution (lab. Frame, MC p) • Frame rotation seems to be worked(z is the tau direction, x is on the plane of beam axis and tau flying axis) • Concentrated to tau axis (because of high g factor) • No dependence observed on f

  7. Angular distribution (t-rest frame, MC) Ep ~ 1/2mt : Lorentz tr. OK! q : isotropic No difference between t+ and t- observed. No polarization ?? f : isotropic

  8. Summary • TaJet and Durhamycut was compared.Currently TaJet gives better performance. • First polarization analysis was performed.(Currently many parts use MC truth.) • For t -> pn mode, no asymmetry observed in p angular distribution • In glddec07 events polarization of taus is not implemented ??

More Related