1 / 12

IEEE 11073 Personal Health Devices work group update

IEEE 11073 Personal Health Devices work group update. Daidi Zhong, Michael J. Kirwan Working Group Co-Chair 22 nd Jan, 2014. Membership. 324 members 206 organizations Weekly conference calls (Thursday 8:15 AM Pacific) Face to face meetings planned every 4 – 5 months

dyami
Download Presentation

IEEE 11073 Personal Health Devices work group update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IEEE 11073 Personal Health Devices work group update Daidi Zhong, Michael J. Kirwan Working Group Co-Chair 22nd Jan, 2014

  2. Membership • 324 members • 206 organizations • Weekly conference calls (Thursday 8:15 AM Pacific) • Face to face meetings planned every 4 – 5 months • Internationalinvolvement in the Work Group • 52.9 % North America • 25.8 % Europe • 21.3 % Far East

  3. Completed Standards (17) • IEEE Std 11073-10404 Dev specialization – Pulse oximeter • IEEE Std 11073-10406 Dev specialization – Basic ECG • IEEE Std 11073-10407 Dev specialization – Blood pressure monitor • IEEE Std 11073-10408 Dev specialization – Thermometer • IEEE Std 11073-10415 Dev specialization – Weighing scale • IEEE Std 11073-10417 Dev specialization – Glucose meter + Revision • IEEE Std 11073-10418 Dev specialization – INR (blood coagulation) • IEEE Std 11073-10420 Dev specialization – Body composition analyzer • IEEE Std 11073-10421 Dev specialization – Peak flow • IEEE Std 11073-10441 Dev specialization – Cardiovascular + Revision • IEEE Std 11073-10442 Dev specialization – Strength • IEEE Std 11073-10471 Dev specialization – Activity hub • IEEE Std 11073-10472 Dev specialization – Medication monitor • IEEE Std 11073-20601 Optimized exchange protocol + Amendment • IEEE Std 11073-00103 Guide for Health informatics - Personal health device communication - Overview

  4. Projects Underway (16) • Other work being drafted • IEEE Std 11073-20601 Optimized exchange protocol (Revision) • IEEE P11073-10404 Dev specialization – Pulse oximeter (Revision) • IEEE P11073-10413 Dev specialization – Respiration rate • IEEE P11073-10419 Dev specialization – Insulin pump • IEEE P11073-10422 Dev specialization – Urine analyzer • IEEE P11073-10423 Dev specialization – Sleep Quality Monitor • IEEE P11073-10424 Dev specialization – Sleep Aponea Breathing Therapy Equipment • IEEE P11073-10425 Dev specialization – Continuous Glucose Meter • IEEE P11073-10417a Dev specialization – Glucose meter (Amendment) • IEEE P11073-10406a Dev specialization – Basic ECG (Amendment) • IEEE P11073-10471a Dev specialization – AI Living Hub (Amendment) • IEEE P11073-10407 Dev specialization – Blood Pressure Monitor (Corrigendum) • IEEE P11073-10408 Dev specialization – Thermometer (Corrigendum) • IEEE P11073-10415 Dev specialization – Weighing Scale (Corrigendum) • IEEE P11073-10420 Dev specialization – Body composition analyzer (Corrigendum) • IEEE P11073-10418 Dev specialization – INR monitor (Corrigendum)

  5. Nomenclature Code Review • Code review Done by Paul (Thanks for his hard work!!) • Based on the PHD Nomenclature Code List maintained by Daidi and Jan. • No conflict with 10101 and 10101a identified in published PHD standards • Agreed to move the codes in published standard into 10101b (with some minor editorial changes) • Agreed to start reserving codes from the unfinished PHD standard after it becomes mature (eg., after 2 rounds of ballot) • Agreed to migrate this manual work to RTMMS.

  6. Completed Initial Ballots in Q4 • Initial Ballots already completed • 11073-10419 (Insulin Pump) – 30 Balloters • 11073-10422 (Urine Analyzer) – 20 Balloters • 11073-10424 (Aponea) – 58 Balloters • 11073-10425 (CGM) – 39 Balloters • 11073-20601 (Protocol) – 50 Balloters

  7. Key Issue in Initial Ballots -10419 • Schedule • 10419 (Insulin Pump) use case requires Agent to deliver a “schedule”-type of data. • The balloted draft uses PM-Store + NumObj; • Voter suggests to define a brand new type of object in DIM. • Current consensus is to inherit (with adaption) the enum–record-metric from 11073-10201

  8. Key Issue in Initial Ballots -10424 • Nom Codes • How to allocate codes for MDC_PRESS_AWAY_AVG and MDC_PRESS_AWAY_MEAN ? Current content in 10101-2004

  9. Key Issue in Initial Ballots -10424 • Nom Codes • Do we need any further synch with external stakeholders? And who? • Contact in PHD: Christoph.Fischer@mcc-med.de NOTE: Based on Paul’s suggestion, we start from 21682

  10. PAR Change Request Issues • We have submitted five PAR Change Requests. • We’ve resolved all the NesCom comments, but didn’t get 11073 sponsor support. • Caused serious delay in these projects • Need to resolve asap

  11. Future F2F Candidates • Feb. 24-27, Geneva, Switzerland, co-locate with ITU SG16 • Early June, Beijing, China, co-locate with Bluetooth Plugfest • 11-13 June, Vienna, Austria, co-locate with pHealth'14

  12. Thank You !

More Related