1 / 13

Directiva COV 1999/13/CE:

Monitoring: Prevederi conform Directivei IPPC si COV. Directiva COV 1999/13/CE:. Generalitati: Articolul 9 (5): Valorile limita de emisie ca masa totala a carbonului organic emis („mg C/Nm 3 “)

edna
Download Presentation

Directiva COV 1999/13/CE:

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Monitoring: Prevederi conform Directivei IPPC si COV Directiva COV 1999/13/CE: Generalitati: Articolul 9 (5): Valorile limita de emisie ca masa totala a carbonului organic emis („mg C/Nm3“) Exceptie: Art. 5 (7) „substantele CMR “ + Art. 5 (8) „substante cu indice de risc R40“: Valorile limita de emisie pentru fiecare substanta Nu se stabileste metoda de masurare in Directiva COV Volumul de gaz pentru racire sau diluare trebuie sa fie exclus la calcularea concentratiei masice a emisiilor! Concetratia masica a emisiilor face referire la conditiile normale (273,15 K; 101,3 kPa) (vezi Nr. 31. Articolul 2)

  2. Articolul 8 (2):La evacuarea printr-un dispozitiv de epurare a gazelor reziduale si la un debit masic al emisiilor gazelor reziduale  10 kg C/h, trebuie sa se monitorize continuu respectarea prevederilor directivei. = Instalarea unui dispozitiv de masurare continua pentru determinarea intregului continut de carbon total. Articolul 8 (3) In toate celelalte cazuri: masuratori continue sau discontinue. La masuratori periodice: La fiecare proces de masurare cel putin trei masuratori discontinue. Nu sunt necesare masuratori, daca pentru respectarea Directivei COV nu este necesar nici un dispozitiv de reducere a emisiilor (Art. 8 (4)).

  3. Articolul 9 (1): • Desfasurarea bilantului anual de solventi de catre operator • ca dovada a respectarii: • valorilor limita de emisie pentru gazele reziduale, a valorilor emisiilor fugitive si valorilor limita ale emisiilor totale • cerintelor planului de reducere

  4. Directiva IPPC: Prevederi Articolul 9 (3) Stabilirea valorilor limita de emisie in autorizatie pentru: anexa III capitolul „aer“ nr. 4 „compusi organici volatili“ si nr. 12 „substante si preparate cu caracteristici demonstrate de afectare, transmisibile pe calea aerului, cancerigene, mutagene sau toxice pentru reproducere“ Articolul 9 (5) Stabilirea cerintelor adecvate pentru monitorizarea emisiilor cu metoda de masurare, frecventa masuratorilor si procedeul de evaluare, in cadrul autorizatiei Obligatia de a preda autoritatii competente datele necesare pentru verificarea respectarii conditiilor din autorizatie

  5. Stabilirea masurarii emisiilor, ca obiectiv prioritar: • Dovada valorilor limita de emisie stabilite in decizie • Cuantificarea COV in cadrul elaborarii bilantului de solventi:Atentie la calcularea randamentului: Determinari concomitente ale gazului brut si epurat! • Autocontrol in functionare si documentarea capacitatii de functionare a dispozitivelor de reducere a emisiilor

  6. Masuratori continue ale concentratiei masice de carbon total la instalatii cu un debit masic  10 kg C/h la evacuari ale gazului rezidual, transmise la o instalatie de epurare conectata Termene: Instalatii noi/ instalatii modificate esential: incepand cu punerea in functiune Instalatie existenta: incepand cu 01.11.2007 Calibrare: la fiecare 5 ani Verificarea functionarii: anual Functionare normala: Exploatarea instalatiei sau desfasurarea activitatii in timpul tuturor perioadelor de timp cu exceptia intervalelor de timp in care au loc pornirea/oprirea si revizia

  7. Alegerea procedeelor de masurarare: • Detector de ionizare cu flama • Utilizarea dispozitivelor de evaluare si masurare omologate • Comunicara publica de catre o autoritate superioara a Romaniei • Elaborarea certificatului referitor la montajul conform al aparatului de masura, de catre un expert autorizat de catre autoritate • Evaluarea: • Formarea mediilor orare pentru functionarea normala • Formarea valorii medii zilnice din valorile medii orare pentru fiecare zi calendaristica, in functie de timpul de operare zilnic („functionare normala“) • Evaluarea printr-un calculator omologat

  8. Respectarea cerintelor: • Nici o valoare medie zilnica formata la o functionare normala nu depaseste valorile limita de emisie • si • b) Nici o medie orara nu este mai mare de 1,5 ori din valorile limita de emisie Realizarea unei evaluari a rezultatelor masuratorii continue in timpul unui an calendaristic Predarea la autoritatea competenta in timpul a 3 luni dupa terminarea fiecarui an calendaristic Pastrarea rezultatelor masuratorilor de catre operatori : 3 ani

  9. Masurarea discontinua a emisiilor din instalatiile cu un debit masic al emisiilor < 10 kg C/h cu evacuarea gazelor reziduale conectata la o instalatie de epurare a gazelor reziduale Indicatie: Masuratori efectuate doar de catre institutii pentru masuratori omologate de catre autoritate! Scop: Inventarierea tehnicii de masurare a starii de functionare cu un comportament nefavorabil al emisiilor -> Masurarea emisiilor din gazul epurat prin prelevare aleatorie -> insa determinarea compozitiei gazului brut poate fi necesara in cazuri individuale (determinarea O5 in bilantul de solventi) Termene: Instalatii noi/ instalatii modificate esential: cel devreme la 3 luni si cel tarziu la 6 luni dupa punerea in functiune si dupa fiecare 3 ani Instalatii existente: Cel tarziu pana la sfarsitul 2007 si apoi la fiecare 3 ani

  10. Numarul masuratorilor discontinue: Desfasurarea a cel putin 3 masuratori discontinue pe o durata de cate o ora in intr-o unitate conforma, in conditii de operare care ar putea duce la emisii maxime Rezultatul masuratorii discontinue se va determina si mentiona ca valoare medie orara. Alegerea procedeului de masurare: Pentru suma substantelor organice: detectorul de ionizare cu flama Important: Incalzirea conductei de prelevare a probelor pana la aparatul de masura pentru a preveni condensarea! Cat de posibil conducte scurte de prelevare a probelor! Pentru substante CMR si substante cu factor de risc R-40: Determinarea fiecarei substante (de ex. GC/MS)

  11. Pentru normarea valorilor masurate ale concentratiei masice a emisiilor la o stare normala : Determinarea marimilor de referinta necesare: Temperatura gazului de evacuare, presiunea statica in gazul de evacuare, procentul vaporilor de apa in gazul rezidual, presiunea atmosferica Pentru determinarea debitului masic al emisiilor m din concentratia masica a emisiilor c: Este necesara determinarea debitului volumic al gazului rezidual V: m = V*c Evaluarea, documentarea: Elaborarea unui raport al masuratorilor prin serviciulmetrologic omologat de catre autoritate Prevederile pentru raportul de masuratori : vezi modelul de raport al masuratorilor Cerintele se considera respectate, daca a) valoarea medie a tuturor masuratorilor discontinue nu depaseste valorile limita a emisiilor si b) nici o medie orara nu trebuie sa aiba mai mult de 1,5 ori valoarea limita de emisie.

  12. Determinarea directa, tehnica metrologica, a emisiilor fugitive in instalatiile cu o epurare a gazelor reziduale (vezi BREF cap. 20.2.3) • Scop: • Cresterea exactitatii la determinarea emisiilor fugitive • Determinarea factorilor de emisie pentru sursele fugitive ale instalatiei (de ex. emisii/ora in procesul de operare desfasurat) • Calculul anual de emisii fugitive cu ajutorul factorilor de emisie pentru fiecare sursa difuza multiplicata cu parametrii de productie (de ex. numarul proceselor de transvazare/an)

  13. Modalitate de procedare: • Identificarea tuturor surselor de emisie difuze intr-o instalatie • Estimarea emisiilor fugitive ale fiecarei surse pe baza factorilor de emisie si parametrilor de productie • Estimarea pentru care surse de emisie este necesara o exactitate mai mare a determinarii emisiilor • Imbunatatirea exactitatii factorilor de emisie pentru surse difuze mai mari • Realizarea unui sistem de inventariere pentru o determinare mai simpla a parametrilor de productie • Calculul emisiilor anuale difuze pe baza factorilor exacti de emisie si a parametrilor de functionare • Derularea bilantului de solventi -> Verificarea respectarii emisiilor fugitive • La modificarile parametr. de functionare este necesara adaptarea calculului!