The 436 Gas Chromatograph provides unparalleled performance and flexibility with its 2-channel architecture, fast ramping oven, electronic flow controls, high pressure inlet, and automation capabilities.
E N D
For Performance and Flexibility 436 series Gas Chromatograph
436 / 456 • Product • Value Proposition • Competitive Positioning • Sales Tools • How to Order
436-GC – 2 Channel Architecture • Fastest Ramping Oven • (up to 170°/min) • Electronic Flow controls • up to 3 modules, 9 channels. • High pressure inlet • Up to 150 psi • Automation capabilities • SPME, dual/duplicate, cool zone • 1 Backflush option • ATEX certified • 2 Inert Inlets • Up to 2 Detectors (1 MS): • Full Color Touchscreen UI • 14 languages! • Fast Acquisition rates • 600 HZ on all Detectors • Smallest Footprint • 32 CM
456-GC – 3 Channel Architecture • 3 Inert Inlets • Up to 4 detectors (1 MS): • Full Color Touchscreen UI • 14 languages! • Fast Acquisition rates • 600 HZ • Fastest Ramping Oven • up to 150°/min • 180°C with Column Oven Insert • Electronic Flow controls • Up to 9 modules, 21 channels. • Inert Inlets • High pressure inlet • Up to 150 psi • Automation capabilities • SPME, dual/duplicate, cool zone • Backflush options • Versatile for analyzer builds • ATEX certified
Inlet & Detector Portfolio Scope *With Liquid Nitrogen Cooling **0.32 mm column only in Narrow bore – smaller ID require precolumn/retention gap
User Interface • Larger • 9”, Full Colour WVGA 800 x 480 Res. • Multi-language • 14 languages, adding one possible! • Local Control • Touch Screen + Hard Keys • Remote access • GC Portal software
Fastest Oven • Ramp Rates up to 180°/min with 456 Column Oven Insert • Resolution <0.1°C , Ambient reject <0.01°C • Cool Down 400° to 50° in <4.5 mins • Easy Access Oven, Removable oven door! 436 Oven Heating Rates 456 Oven Heating Rates (insert) 456 Oven Heating Rates
8400/8410 Sampler • 2 different user Profiles: • Large throughput 8400 • Small volume, but best repeatability 8410 • All models • 2 ml vials only 8400 vs 3 different vial sizes (2,5,10 ml) in 8410 • Better accuracy than manual • Dual / Duplicate Capability • Inject Into Two Ports • Requires Only One Tower • Control Through LUI • Control via Work Station • Side mounted Sampler. • Syringe not over hot injection port • SPME mode option
8400/8410 Sampler • Flow Through Cell. • On-line sampling of liquids • Always fresh sample available • No time-consuming sample collection
8400/8410 Sampler • SPME. • Integrated • Part of method • Available on 436/456 & 8400/8410 • Large Solvent vials • Extends capacity of solvent vials to 100 ml • Solvent drain/waste line • No more full vials…. And a safe accumulation of solvent
Inert Mini Splitter • What is it: • In-line Splitter • Vent outlet for back flush • Low ithermal mass • Low dead volume • External heated (column oven) • Less connections = robust • Inert (UltiMetalTM) • No polymers used (Septa, O-rings) • Applicable to: • Gas samples only • SPT, PDHID based applications • Sulfur in Gas samples
Comparing Mini Splitter & S/SL • Mini Splitter • Smaller • Better Repeatability • S/SL • liquid injections • Separate heating • Different Liner designs Septum purge Metal column Carrier gas in Vent out Vent out Heating block Capillary column Capillary column
Safety Options • H2 Sensor - Senses Hydrogen in oven • Safety Shutdown when Hazardous error • Hydrogen flows set to zero • Other gas supply unchanged • Detectors set to off (also for filaments!) • Heated zones set to low (oven, injector, detector) • (ATEX) Certified • Personal safety on the lab • No flying parts after an “explosion”
Electronic Flow Controls • EFC Resolution: 0.001 psi for Superior Retention Time Stability Measured under standard conditions in split mode using CP-8400 autosampler. Different conditions and/or samples will affect the results.
Need for Fast? • Reduce column ID from 0.25 to 0.1mm • Reduce column length from 15 to 4 mtr • Increase column head pressure from 7 to 21 psi • Increase oven ramp rate from 10 to 65 ºC/min • Increase data rate from 25 to 200 Hz Sample is typical diesel sample in both chromatograms, run on apolar column phase..
Platform Flexibility – 4X6 can offer it! • Different Levels of ‘Delivery’, • depending on customer expectation (436 and 456 both)
Platform Flexibility Solutions - Examples Integrating Stream Conditioners Process Valves Valves with Micro packed Columns Multi-Stream Sampling and Automation LSV with Sample Port
Platform Flexibility Solutions - Examples Pneumatic High Temp. / High Pressure On/Off valve in sample line Packed column(-s) installed in Multi-valve oven
Value Proposition 436 • Confidence in Data • Proven Results (designed, built, tested, documented & commissioned to spec) • Software for automation, calculus, reporting • Electronic flow control • Better ROI / Lower Cost of Ownership • Robust Platform - Low maintenance due to superior build quality • Fast cycle times • Cost efficient • Space efficient • Flexibility for tailoring to your need! • 2 channels with MS • Solution Driven Options
Value Proposition 456 • Confidence in Data • Proven Results (designed, built, tested, documented & commissioned to spec) • Software for automation, calculus, reporting • Electronic flow control • Better ROI / Lower Cost of Ownership • Robust Platform - Low maintenance due to superior build quality • Fast cycle times • Cost efficient • Flexibility for tailoring to your need! • 4 channels with MS • Solution Driven Options
Competitive Landscape • 436 USP: • Size • Allows ‘all applications’ (2 channel – full suite inlets/detectors) • PFPD! • 9” WVGA Touch Screen w. GC Language Localization • Fast oven (also works with narrow bore – Intuv’O’). • 84X0 • Liquid sampler with added capability (SPME…) • Dual / Duplicate sampling • Software: CompassCDS with Hydrocarbon Reporting • Scalable, C/S, across brands.
Competitive Landscape • 456 USP: • Unsurpassed configurability • Allows ‘all applications’ • 4 channel w. MS • Full suite inlets/detectors • PFPD • 9 EFC Modules, 8+8 Electr. Events, 16 timed events, up to 9 heated zones • 9” WVGA Touch Screen w. GC Language Localization • Fastest oven with oven insert. • 84X0 • Liquid sampler with added capability (SPME…) • Dual / Duplicate sampling • Software: CompassCDS with Hydrocarbon Reporting • Scalable, C/S, across brands.
Competitive Brands side by side *with oven insert
Competitive Brands side by side **measured in split mode ***measured in splitless mode
Competitive Landscape • Agilent - Intuvo: • Guard Chip • Works best for dirty samples, no need for other applications • Leak prone…depends on user skill • 1 channel only • Fast Heating option commonly not used (Temp transfer…) • No Wide bore columns only, max col length 50m • So not compliant to many solutions! • Not many valve options • Intuvo pricing. • Sometimes allows competing with 2*436 (productivity, Throughput) • Intuvo Consumable pricing
Competitive Landscape • Shimadzu - Nexis: • Low-Quality Plastic Covers… • User Interface is user unfriendly. • ‘Non’-features: • ClickTek Nut – ‘no tools’, special jig? Max Temperature 350°C, no COC! • Oven Light – Varians 3800 had that in 1998, and it was deemed unneeded….
Competitive Landscape • Shimadzu - Nexis: • Flow Control… • FID linearity… • known problem in GC-2010 • ≠ 107 FID-2030
Sales Tools • PPT 436 / 456 • Customer Value • How to order • Competitive • Product Brochure • App Notes, Posters, Demonstrated Analysis