1 / 18

MC of CBM Silicon Tracker Status Report

MC of CBM Silicon Tracker Status Report. Valeri Saveliev Obninsk State University, Russia 10.05.2004 GSI, Darmstadt. CBM Spectrometer and Silicon Tracker (STS). STS: Station z Rmin Rmax [cm] [cm] [cm] 1 5 0.5 2.5 2 10 0.5 5.0 3 20 1.0 10.0 4 30 1.5 15.0 5 40 2.0 20.0

elisha
Download Presentation

MC of CBM Silicon Tracker Status Report

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MC of CBM Silicon TrackerStatus Report Valeri Saveliev Obninsk State University, Russia 10.05.2004 GSI, Darmstadt V.Saveliev

  2. CBM Spectrometer and Silicon Tracker (STS) STS: Station z Rmin Rmax [cm] [cm] [cm] 1 5 0.5 2.5 2 10 0.5 5.0 3 20 1.0 10.0 4 30 1.5 15.0 5 40 2.0 20.0 6 80 4.0 40.0 7 100 5.0 50.0 Run Conditions: BX 10 MHz • STS: • Momentum measurement (Mag. Field); • Primary Vertex Reconstruction; • Secondary Vertex Recionstruction; V.Saveliev

  3. MC of CBM Si Tracker Moscow State University – Si Technology and Production, Moscow Engineering and Physics Institute (University): Front-End Electronics; Obninsk State University: MC and Analysis; St. Petersburg KRI, SKBM: Support Design and Construction. Monte Carlo: Obninsk State University: V.Saveliev, PhD student D.Rizjikov, A.Golovin, Student O.Stotski St. Petersburg : V.Kondratiev V.Saveliev

  4. Monte Carlo of CBM Silicon Tracker • VMC CBM Simulation Framework – is Good Step for Starting. • Simulation Environment for STS: • Accounts and Connections to GSI is established from Obninsk and St. Petersburg; • Local Version of CBM VMC has been installed in Obninsk Uni on Linux Cluster ( CPU time is ~10 Min for full simulation of Au+Au event 25 AGeV ); V.Saveliev

  5. MC of CBM G4 version of VMC CBM Central Au+Au at 25 AGeV V.Saveliev

  6. MC of STS CBM Event 1, Proj. (197,79), Targ (179,79), E= 25 GeV/u, Track 1641 / 1641 STS detector sts_station_1: 505 Hits STS detector sts_station_2: 677 Hits STS detector sts_station_3: 706 Hits STS detector sts_station_4: 721 Hits STS detector sts_station_5: 720 Hits STS detector sts_station_6: 706 Hits STS detector sts_station_7: 699 Hits V.Saveliev

  7. Si-Strip Sensors with Stereo Angles Simplest solution for technology: Double Side Si Strip Detectors with Stereo angles on single wafer Implemented in G4 CBM Geometry V.Saveliev

  8. STS Sensors versions: Rf Implemented in G4 CBM Geometry V.Saveliev

  9. STS Sensors versions LL Long Ladder Si Strip Detectors (Si LC Project) V.Saveliev

  10. Occupancy of Silicon Tracker Hits density (central Au+Au at 25 AGeV) in STS V.Saveliev

  11. Segmentation of Silicon Strip Tracker Occupancy 1%; 5% ------------------------------------------------------------- Strip Pitch 25 mm; 12.5 mm ------------------------------------------------------------- Strip Length 0.4 mm 4 mm Analysis in progress Hits density of Station1 of STS (central Au+Au at 25 AGeV) V.Saveliev

  12. Thickness of Si-Strip Tracker Sensors Multiple Scattering is limitations: Study is in progress: Thickness of Si Sensors is in the range 100 – 300 mkm V.Saveliev

  13. Radiation Environment ? V.Saveliev

  14. Radiation Environment ? GaAs:Cr for HEP - radiation testsYu Arestov (IHEP) IHEP, Protvino NCPHEP, Minsk SIPT, Tomsk ICBP, Puschino V.Saveliev

  15. Doping GaAs by Chromiumthe 5-year practice of a new technology in Tomsk • World studies of GaAs irradiation tolerance related mainly to GaAs structures of the previous generation. • A new unique production technology of GaAs:Cr (doped by Chromium) belongs to Tomsk. • As was earlier shown by estimates and by the first measurements (Protvino, RAL), GaAs:Cr radiation hardness can be higher than that of Si by a factor of 10 or larger. V.Saveliev

  16. More Detailed Analysis of STS Station3: St Petersburg V.Kondratiev V.Saveliev

  17. More Detailed Analysis of Station3: St Petersburg V.Kondratiev V.Saveliev

  18. Next Steps: The Tool for Monte Carlo Simulation is exist • Position Resolution of Si Strip Detectors and Segmentation fits to CBM Requirements. • Geometrical Layout of Si-Strip Stations of STS. • Support Design and Implementation. • Radiation Environment Analysis. • Hits Structure, • Digitalization, • Connection to the Reconstruction Chain, • Optimization of Si-Strip Station of STS for the physics of CBM Open Charm and Low Mass Vector Mesons. V.Saveliev

More Related