Summary from the slides of M.Holz presented on 3/7/2012 at LIU-SPS- ecloud

Multipactor test stand. Summary from the slides of M.Holz presented on 3/7/2012 at LIU-SPS- ecloud. M.Taborelli. Reminder: Goals and Experimental Set-up. Quality control for different carbon coatings in the vacuum chamber, independent from the beam and accelerator’s schedule

eman
Download Presentation

Summary from the slides of M.Holz presented on 3/7/2012 at LIU-SPS- ecloud

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Multipactor test stand Summary from the slides of M.Holz presented on 3/7/2012 at LIU-SPS-ecloud M.Taborelli

  2. Reminder: Goals and Experimental Set-up • Quality control for different carbon coatings in the vacuum chamber, independent from the beam and accelerator’s schedule • A tungsten wire drawn along a SPS magnet vacuum chamber (6.4 m): geometry of a coaxial transmission line (transversal electromagnetic waves). The chamber becomes a resonator and we use standing wave pattern to achieve the necessary E-Field strength Michael Holz BE-RF-BR

  3. Summary of 2011 • Only a single test was performed on carbon coated chambers • For all measurements with magnetic field below 3 kA, no reflected power nor outgassing could be observed, corresponding to complete suppression of multipacting • When using 3 kA through the magnet, a single rise in reflected power occurred, but was not reproducible. However, pressure activity remained for all consecutive measurements.

  4. 2012 uncoated MBB013 Reflected power Pressure rise • chamber as-received from chemical cleaning • Reflection at very low power threshold as expected • Cyclotron resonance at the expected value • pressure rise is not well correlated with the reflected power influence of the history of conditioning (sequence of measurements)? E F D C B A

  5. 2012 carbon coated MBB013 (hollow cathode) • Reflection observed at higher power threshold compared to uncoated • Almost independent from the dipole magnetic field strength:  possibly multipacting occurs outside the dipole chamber • Pressure rise is one order of magnitude lower than for uncoated • NB: the chamber of coated in hollow cathode (only top and bottom faces are coated)…and the lowest threshold of power is for B=0

  6. High magnetic field @130.1 MHz, coated • No change with respect to lower magnetic fields (in 2011 we had a non reproducibility issue in these conditions)

  7. Conclusions • only slight reflected power and pressure rises in a hollow cathode coated chamber • possibility of multipacting outside the dipole: put solenoids to verify this • redo pressure rise measurements with a well defined conditioning state • Calculate the field pattern to verify the possibility of multipacting at the uncoated regions (sides) of the chamber