Wireless D LP Panel HDL-MPL8-RF.18

Wireless D LP Panel HDL-MPL8-RF.18. Functions. The wireless power interface provides the working voltage, a DLP panel can control 4 wireless power interfaces at the same time. It uses wireless communication, and it must work in conjunction with mesh gateway.

epellegrino
Download Presentation

Wireless D LP Panel HDL-MPL8-RF.18

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Wireless DLP Panel HDL-MPL8-RF.18

  2. Functions The wireless power interface provides the working voltage, a DLP panel can control 4 wireless power interfaces at the same time. It uses wireless communication, and it must work in conjunction with mesh gateway. Multiple pages- four normal button pages, one specified page for Floor Heating, HVAC, and Music control is available. Each of the keys can have a user designed icon. Single button mode and double button mode are available. The mutual exclusion of buttons is available. The following functions are included: IR Receiver, Lock, Turn on/off AC, Cooling & heating for AC. Auto temperature setting, Fan Speed regulation, AC Mode setting, AC Temperature regulation, backlight adjustment, AC Lock, Backlight and status light setting, floor heating temperature and mode setting etc.

  3. Setup Before user can configure the wireless DLP normally, need to set the wireless parameters for it via mesh gateway, below is the setting steps: 1- Press the "PROG" button 3 times continuously, the RGB LED will flash quickly that means the gateway enters the wireless setup mode. 2- Long press the DLP's first and eighth buttons at the same time to enter the setting page, select "WIRELESS", then it will enter the wireless setup mode.

  4. Setup 3- Click the "Search" button, this gateway and panel will be shown.

  5. Setup 4- Select the node, you will be able to change its ID and remark it. (the Subnet ID must be same as the gateway's).

  6. Setup 5- Click "Modify Settings of Selection", and it will show "configurate successful", then all its wireless parameters will follow the gateway's (Band, Frequency and PSK). 6- Click "all Node Exit Setup", then the gateway and the panel will exit the wireless setup mode. 7- Go to the HDL Buspro setup tool's main interface to search and add the wireless DLP, then can start to configure it via the gateway.

  7. Enable/disable the IR receive, Temp, Date and time Basic Information Set the LCD and LED brightness Adjust temperature Enable/disable broadcasting the Temperature to other device

  8. Key setting Select the configuring page Remark Key mode Test: Test the key function in the software, rather than press the physical button.

  9. Key setting Frequently activation mode: Single On: send out one ON command when pressed. Single Off: send out one OFF command when pressed. Single On/Off: send out one ON/OFF (toggle) command when pressed. Momentary: send out one ON command when pressed down, send out one OFF command when released. Many ON: can send out up to 99 ON commands when pressed. Many OFF: can send out up to 99 OFF commands when pressed Many ON/OFF: can send out up to 99 ON/OFF (toggle) commands when pressed. Dblclick/single switch:Double clicking can control up to 49 targets, a single click can only control 1 target Dblclick/combination switch:Both double click and combination switch can control up to 49 targets

  10. Key setting Dimming: Valid- enable dimming when long pressed Invalid- Disable dimming, just on/off Dimming value: Toggle- when turn on light, the brightness will go to 100% Memory- save the brightness, when turn on light, the brightness will go to last brightness before turn off Keystroke status: Valid - Enable the LED indicator of the key Invalid - Disable the LED indicator of the key

  11. Key setting Mutual Exclusion: The key Many mode such as Many on, Many on/off can be set to mutual exclusion. After setting mutual exclusion, only the last controlled key can indicate its status (on), other keys’ status in mutual exclusion group will be off. Group NO.

  12. Key setting The mutual exclusion is originally designed to solve the problem described below, Key1 control (Many on) channel1 and 2 of dimmer go to 30% Key2 control (Many on) channel1 and 2 of dimmer go to 60% Key3 control (Many on) channel1 and 2 of dimmer go to 90% Press the key 1, and then key 2, and then key 3, now all LED indicators of the three keys are on, the level of two channels is 90%. If we set mutual exclusion for these three keys, then the LED indicator of the last pressed key will be on, all other indicators are off.

  13. Key setting Double Key Merge: e.g., if we merge key1 and key2, these two keys will act as one key, the right key (key2) is same as the left key (key1).

  14. Key setting Key Combination Way:All keys in the combination mode will only perform the function of the top button

  15. Key setting The ID of the control target Configure the target for each key

  16. Key setting Frequently used command types: Invalid: Disable the command. Scene Switch: Used to recall the scene that you have created in the dimmer or relay. Sequence Switch: Used To recall the sequence that you have created in the dimmer or relay. Universal Switch: Used to send infrared code number, set logic flag On or Off, set the hotel door bell services , disable or enable Motion sensor, … Single channel lighting control: Used to turn on/off one channel (with brightness level & running time in the command) Curtain Switch: Used to open, close or stop the curtain. Broadcast scene: Used to recall some certain scenes (same scene no.) of all Areas of a dimmer or relay module. Broadcast Channel: Used to turn on/off all channels of a relay module or set all channels of a dimmer to the same level.

  17. AC DLP+HVAC: Fill in HVAC ID and select New type Right click to refresh and read the status, or adjust the setting and save it to the DLP.

  18. AC DLP+IR Emitter: Check the box Send “universal switch” to SB-IR-EM to control AC. Tips: the parameter 1 is the index no. in SB-IR-EM.

  19. AC Enable FAN speed and Mode

  20. AC Set temperature range

  21. AC Set temperature source

  22. Floor heating&Music For Floor Heating and Music configuration, please refer to floor heating module and Music module.

  23. Channel Information Each power interface has 3 output channels, up to 4 power interfaces can be connected in parallel, then there are 12 channels in total. The panel will assign the dimmer address1-4 for the connected power interfaces by default. User can control the outputs by "on/off" option to check the power interface's address. If connected 1power interface, 3 channels will be shown; if connected 4 power interfaces, 12 channels will be shown.

  24. Channel Information Remark: Remark the channel for the easy management. Load type: Select the corresponding load type for each channel according to the real situation; it is just like a remark, would not affect the behavior of lamps. Default selection – Undefined. Low limit: If setup the lower limit for the channel, when below to this value, the output is 0. The Lower limit is useful if you unfortunately have some lamps which produce unstable (trembling) light when dimming in low segment. You can bypass the unstable segment by setting a suitable Lower limit. Max level: The max output brightness of a channel. Test: It is used to test the loads after installation.

  25. Dimmer Setting Show the information of the power interface that connect with the DLP

  26. Dimmer Setting Dimmer Turnoff Temperature: Set the temperature for protection, when the panel’s detected temperature reaches to the setting temperature, it will turn off the connected loads automatically. When the detected temperature is lower than the setting temperature, it will restore the loads' status again. Toggle- when turn on light, the brightness will go to 100% Memory- save the brightness, when turn on light, the brightness will go to last brightness before turn off