890 likes | 1.28k Views
FoamPro Mechanic Program (2000 Series & 3012). Overview. Calibration and setup System warnings Service and maintenance (See Installation and Operation Manual for detailed instructions). Calibration And Setup Mode. Enter Calibration And Setup.
E N D
Overview • Calibration and setup • System warnings • Service and maintenance (See Installation and Operation Manual for detailed instructions)
Enter Calibration And Setup • Use a 3/32” allen wrench, remove the left screw • Place it and O-Ring in a safe place • Insert allen wrench into left hole and lightly push on internal dip switch
Enter Calibration And Setup Flashes “ELEC / SEtUP” 2000 System 3012 System Push “SELECT” button Flashes “HYD / SEtUP” (Follow calibration procedures)
Remove screw Save screw Insert allen wrench Push select button Enter Calibration Mode Summary Flashes “ELEC / SEtUP” 2000 System 3012 System Flashes “HYD / SEtUP”
Exit Calibration And Setup • Insert allen wrench into left hole and lightly push on internal dip switch • “HYPro” appears then…
Exit Calibration And Setup • Display shows: • “0” in “FLOW” mode • Replace screw • System is operational
Calibration By Water Flow • Enter calibration • Push “SELECT” button until light under “FLOW” is illuminated
Calibration By Water Flow • Establish water flow and bleed air from pitot tube
Calibration By Water Flow • Note tip size • Read pitot pressure gauge
Calibration By Water Flow Tip size and pressure gauge reading determine gpm
Calibration By Water Flow • Raise or lower the display to match flow chart
Calibration By Water Flow • Increase or decrease pump pressure • Repeat calibration steps
Calibration By Water Flow Tip size and pressure gauge reading determine gpm
Calibration By Water Flow • Raise or lower display to match the 2nd reading from flow chart • Exit calibration
Light under “FLOW” Pressure reading Obtain flow from chart Set water flow Repeat and verify Set water flow Calibration By Water Flow Summary
Calibration By Total Water • Fill water tank • Enter calibration • Push “SELECT” button until light under “TOTAL WATER” is illuminated • Pump a known volume of water
Calibration By Total Water • 1,000 gallons of water pumped • “TOTAL WATER” shows 771 gallons • Push “UP” button
Calibration By Total Water • Set at 1,000 gallons • Exit calibration
Calibration by Total Water Summary Pump a known volume of water Light under “TOTAL WATER” or to known volume Repeat and verify
Simulated Flow Default • After calibrating flowmeter, set simulated flow • Enter calibration • Push “SELECT” button until light under “FLOW” is illuminated
Simulated Flow Default • In “FLOW” mode • Push the “UP” and “DOWN” buttons at same time to enter simulated flow mode
Simulated Flow Default • Increase or decrease until “FLOW” reading is set to desired level
Simulated Flow Default • Push “UP” and “DOWN” buttons at same time to exit simulated flow • Exit calibration
Simulated Flow Summary Light under “FLOW” & to enter Lower to set flow & to exit
Dual-Tank Or Remote Start/StopSet-Up(Not required for Advanced Feature Controller)
Dual-Tank Or Remote Start/Stop • Enter calibration • Display head will flash “ELEC”/”HYD” and “SEtUP”
Dual-Tank Or Remote Start/Stop • Remove right screw • Insert allen wrench into right hole and lightly push on internal dip switch
Dual-Tank Or Remote Start/Stop Press the “UP” button for Dual-Tank mode
Dual-Tank Or Remote Start/Stop Dual-Tank mode Tank A Tank B
Dual-Tank Or Remote Start/Stop Press the “DOWN” button for Remote Start/Stop mode
Dual-Tank Or Remote Start/Stop • If a dual-tank system is in “Remote Start/Stop” mode (“PC” display reading), switching Dual-Tank Valve from Tank A to Tank B will start the foam pump
Dual-Tank Or Remote Start/Stop • Exit calibration • Replace right screw
Dual-Tank Or Remote Start/Stop Summary Depress switch in left then right hole or Dual-Tank Remote Start/Stop
Dual-Tank Or Remote Start/Stop Summary Tank A Dual-Tank Tank B Remote Start/Stop
Injection Percentage Default • Enter calibration • Push “SELECT” button until light under “%” is illuminated
Injection Percentage Default Single Tank • Raise or lower the “%” number to your desired default
Injection Percentage Default Dual-Tank • Position selector to Tank “A” • Raise or lower the “%” number to your desired default
Injection Percentage Default Dual-Tank • Position selector to Tank “B” • Raise or lower the “%” number to your desired default
Injection Percentage Default Remote Start/Stop • Raise or lower the “%” number to desired default
Injection Percentage Default Summary Dual-tank light under “%” Remote Start/Stop light under “%” Push or Select Tank A or B and push or
Foam Pump Calibration • Located on discharge side of foam pump • Move handle from “INJECT” to “CAL/FLUSH”
Foam Pump Calibration • Place a graduated container at the hose coming from the “CAL/FLUSH” valve
Foam Pump Calibration • Enter calibration • Push “Select” button until light under “TOTAL FOAM” is illuminated
Foam Pump Calibration • Press the “FOAM” button • Resets to 0.00 • Starts foam pump • Fill container • Press the “FOAM” button to stop