Optical position sensor for the VWS. Project Update

Optical position sensor for the VWS. Project Update . Student Meeting 23/07/2012. 1. Initial remarks. A) Tests have validate the usage of SMF 9/125um assembly B) Focuser configuration has proved to be the best in terms of accuracy and coupling efficiency.

gerry
Download Presentation

Optical position sensor for the VWS. Project Update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Optical position sensor for the VWS. Project Update Student Meeting 23/07/2012

  2. 1. Initial remarks • A) Tests have validate the usage of SMF 9/125um assembly • B) Focuser configuration has proved to be the best in terms of accuracy and coupling efficiency. • C) Commercial lens 352400 with Thorlabs housing has proved it’s performance and low aberration (UHV and High Temp comp). • D) Tests to be done: • 1. Validate usage of commercial focuser from Schafter + Kirhhoff: UHV and High Temp comp, in principle. • 2. Validate usage of External focuser (calibration from outside very long focal distance 9cm) • 3. Which side of the disk to use (High ref chrome or Glass side) • 4. Accuracy comparisons with commercial enconder RON 225

  3. 2.Components point of view • Laser: BOB1310FP (1310nm) from “BOB Lasers” • Photodiode: PTIN155ST83-N-O (1310nm) from “Laser Comp.” • Circulator: PIOC-3-13-P-2-1-55 from “Fiberer” • Opticalfibre air side: Standard CernDrakaRadHardfibre. • Feedthrough + Adapter:FO-SM-1300-16CF + FO-FC CV from “Lewvac” • Optical fibre UHV Side (FC/PC-FC/APC): Sedi-Fibres? NASA connectors • Focuser: 352440 lens + Thorlabs housing from “Thorlabs” or 60FC-4-A4-03 + 5M-A4-0-03-S from “Schafter + Kirchhoff”

  4. 3. Tests done: • 352440 Lens + Thorlabs Housing • Lens adjust and fixing: Retaining Rings • Difficult adjust: Change D1 = Change D2 • Possible misalignments for vibration • No glues • A) Validation Commercial focuser: • Schafter + Kirchhoff • Lens adjust: High precision screws • Lens fixing: Indirect clamping • Independent lens calibration • Compact system • No glues • Better coupling eff. (Good aligned)

  5. 3. Tests done: • B) Signal Acquisition and analysis: • 1. Duty Cycle: Why D<< 50%??!! D=43% • Simulations : 49-50% • Practical: 42 – 46 % Cause 1: Reflection parts of each track are smaller than non reflection. Cause 2: Rectangular tracks, not precise angular information.

  6. 3. Tests done: • B) Signal Acquisition and analysis: • 1.Duty cycle: • Solution -> Detecting only rising edge • Resolution -> Reduced to 1/2