810 likes | 2.49k Views
PowerLogic EGX300 Training. Integrated gateway-server for entry-level system monitoring. View device data through a simple browser – no software needed. EGX300 web page. Trend plots. Data log files. EGX100. Pull information into web pages from other PowerLogic gateways (PM8ECC, EGX100).
E N D
PowerLogic EGX300 Training Integrated gateway-server for entry-level system monitoring
View device data through a simple browser – no software needed EGX300 web page Trend plots Data log files EGX100 Pull information into web pages from other PowerLogic gateways (PM8ECC, EGX100) EGX300 ION 6200 PM800 Micrologic Sepam EGX300 Overview
Minimum System Requirements Physical Characteristic Ethernet Serial Exterior TRe Setup AutoDiscovery Data Export Monitor Single Device Page Summary Pages Logging Custom Pages Documentation Control Resets Diagnostic Maintenance Advance Feature Remote Device connection Custom Logo Supported Devices Application Architecture Obsolescence Plan Legacy Solutions Language File Customization Accessory Kits FAQ Appendix Changes in red denotes Phase 2 functions Outline Training
Minimum System Requirements Although there is NO need to install any software, the computer accessing EGX300 will need to have a browser installed. We support: • Microsoft Internet Explorer 6.0 or higher
Physical Characteristic: Ethernet • Ethernet • 10/100BaseTx • Media Type: • 10T/100Tx Auto • 10BaseT-HD • 10BaseT-FD • 100BaseTx-HD • 100BaseTx-FD • Framing: Ethernet II & 802.3 (SNAP) • IP Parameters: Address, Subnet Mask, & Default Gateway • Protocols: HTTP, ModbusTCP/IP, FTP, SNMP (MIB II), SNTP, SMTP • Connector: RJ45 • Pinout: Industry standard • Supports 48 concurrent ModbusTCP/IP connections • Duplicate IP address detection (FDR basic)
Physical Characteristic: Serial • Serial Line • All lines optically isolated • Physical interface: RS485 4-wire, RS485 2-wire, RS232 • Protocols: ModbusRTU, POWERLOGIC (SY/MAX), ModbusASCII, Jbus • Baud: 2400–38400bps (RS485); 2400-57600bps (RS232 ASCII) • Parity: None, Even, & Odd • Response timeout: 0.1 to 10 seconds (default = 3 seconds) • Connector: • RS485 5 position plugable screw-terminal • RS232 RJ45 • Pinout: • RS232 Industry standard EIA561 for RJ45 • Note: EGX300 is internally connected: no need to physically connect the EGX300 for two wire mode.
Physical Characteristic: Exterior RJ45 Ethernet port (IEEE802.3af) Control power (screw terminal connector) LED indicator for power & status Recessed reset button LED indicators for Ethernet and serial communications
Physical Characteristic: Exterior RS485 serial port (screw terminal connector) Bias, Termination, and 2-wire / 4-wire jumper switches RS232 serial port (RJ45 connector)
Transparent Ready {TRe} • Embedded web server provides real-time tabular data views for all supported device types • Single Device Basic Readings - Includes Analog Meters view with -Three-phase Current - Real, Reactive, and Apparent Power - Line-line phase Voltage - Line-neutral phase Voltage • Summary Device Views • Circuit Summary • Load Current Summary • Demand Current Summary • Power Summary • Energy Summary • Real-time Trending Graph view (multi-device, multi-topic) • Includes a running table of min/max/avg values • Includes a tabular view of trended data • Advanced users can create custom web views
TRe: Setup • Ethernet & TCP/IP • Serial Port • Remote Device Connections • Device List • Device Logging • Device Log Export • Date and Time • SNMP Parameters • Modbus TCP/IP Filtering • Documentation Links • User Accounts • Web Page Access • Preferences
TRe: Setup => Auto Discovery • EGX300 features the ability to “Auto Discover” devices in its daisy chain • The EGX300 will not find remote devices; the user will need to define a locate address and remote address • Look under the device list and scroll to the bottom of the page • The user needs to setup the right baud rate and settings for this ability to work. Press to Discover
Note: Device List • Devices can either be manually entered or auto discovered. • You can manually enter a device and not have it present; however, you will not have a page created for the device until the device is connected. • There should not be a problem for communication because the EGX300 will not detect the device.
TRe: Setup => Data Export • Users have four options • Disable • Export via FTP • Export via HTTP • Export via E-mail • Users will have to setup logging first before choosing either options • Uses can now only send “incremental” data versus ALL data with the EGX400 • Data can be push incrementally • For Equipment Plants, the option is usually disable by default.
TRe: Monitor => Single Device Page • The EGX300 has the ability to display real time readings from devices. • The devices can be selected individually • All data displayed has been scaled and set at factory • Any unique requests will have to be done as a custom page • Analog Meter Display is Available
TRe: Monitor => Summary Pages Summary Pages are standard with TRe level 2 support. Users can select ALL or individual pages to be displayed the summary pages. Pages to be displayed: • Circuit Summary • Load Current • Demand Current • Power • Energy
Embedded web server provides user selectable topics per device Provides logging function to store data from serial devices on 5, 10,15, 20, 30, or 60 minute intervals Embedded web server provides a graphical view of stored data logs Provides Simple Mail Transfer Protocol (SMTP) to E-mail stored device data logs on user defined intervals Provides File Transfer Protocol (FTP) server to access device data logs Provides the ability to send data logs manually with the click of a button TRe: Monitoring => Logging
TRe: Monitoring => Real Time Trending • Real Time Trending with devices through web interface • Can choose multiple topics
TRe: Monitoring => Custom Pages • EGX300 will allow users to transfer their own custom pages • Custom pages will allow users to have the flexibility to create their own custom solution
TRe: Documentation • As part of TRe, users can transfer documentation or create documentation links • Users can store up to 512 Mb • The documentation can link to other devices that have web server capabilities
Control • On the Control page, users can reset the values of their individual devices.
Diagnostic • Users can: • Look at stats for the EGX300 • Read devices on this page • Check Communication Connection • The stats information will be used by design and tech support to analyze the system situation
Diagnostic: Accumulative Connections • Users can click accumulative connections and displayed previous connections • This is valuable in terms of security to keep track of users who have logged on before.
Maintenance Log • EGX300 provides the ability to record maintenance log files. • Typical users can record simple text information about system or challenges.
Advance Features: Remote Connection • Under Remote Device Connection, users can setup logging remotely and access devices remotely
Custom Logo Logo • Users can customize splash screen, logo, color, and favicon • Please refer to the white paper for detail specifications • This will allow Integrators to add more value for their services Splash Screen
Viewable Device Type • Ability to hide un needed device type from the device list
BCM BCPM A/B/C CM100/200 CM2000 Series Meters CM3000 Series Meters CM4000 Series Meters DM6200 E5600 Enercept Energy Meter ION6200 ION7300 ION7650 MCM Micrologic A Micrologic H Micrologic P MicrologicA+CCM MicrologicH+CCM MicrologicP+CCM Model98 Motorlogic Plus Motorlogic Plus II MVSS/RVSS PM210 PM600 Series Meters PM700 Series Meters PM800 Series Meters PM1200 Sepam 2000 Sepam Series 10 Sepam Series 20 Sepam Series 40 Sepam Series 80 Device Types for Support => Refer to next slides for level of support
Level of Support through EGX300 *ION E can not be supported through the EGX300 with full capabilities due to no support of ION protocol
Application Architecture • How to address the following situations: • Two and Four Wire Systems • Remote Access to Other Gateways
Two and Four Wire Systems Ethernet Network RS-485 (4 Wire) RS-485 (2 Wire) N < 32 Up to 64 Devices can be view by one EGX300 EGX300 can remotely connect to other gateways
Remote Access to Other Gateways Ethernet EGX100 EGX300 EGX300 can poll EGX100 through Ethernet
EGX300 will be introduced by Q1 2009 We will stop selling EGX400 by Q1 2010 We will have stock to replace existing EGX400 for warranty/repair purposes for about three years Special Substitution Use Cases (refer to following slides after): Second Serial Port Older Systems Obsolescence Plan
Second Serial Port Ethernet EGX100 EGX300 N <= 32 N <= 32 Up to 64 Devices can be viewed by one EGX300 EGX300 can remotely connect to other gateways
Legacy Systems Ethernet EGX300 CNV100 2 wire System 4 wire System
Accessory Kit • Allows configuration via RS232 serial or Ethernet port • Kit Contents • RJ45 to DB9F adapter • CAT5 Crossover cable, 3-meters (10-feet), orange • Instruction sheet • Ordering Information • TCSEAK0100 • Market Price (average) • $50 (USD)
IF USB ONLY, need converter to serial Configuration Kit
Accessories - PoE Injector (IEEE 802.3af) • Active mid-span device with universal power cord • Contents • Universal power cord (IEC-60320-C13 & IEC-60320-C14, 3-meters (10-feet) • Plug adapters for Australia, Europe, UK, USA • Instruction sheet • Ordering Information • TCSEAV0100 • Market Price (average) • $80 (USD)
FAQ • Are we limited to the predefine topics already in the logging section setup? • No, we can add more topics; however, we are limited to logging 12 topics • How many languages can the EGX300 support? • We can support up to 8 languages with 4 default (English, French, Spanish, German) • What type of file formats are supported? • Most files formats are supported, e.g. jpeg, swf, doc, xls • Can divide the network into 2 segments to get faster response? • Buy one EGX300 and one EGX100 • Do we support other web browsers? • Our pages can be viewed in other browsers
FAQ Continuation • Do we support ION protocol? • At this time, we do not support ION protocol. • How much memory does EGX300 support? • 512 Mb • How many e-mails will be sent from the EGX300 for logging? • The number of e-mails sent will be determine by number of devices logged. • Does EGX300 support SNMP? • Yes, it supports the standard MIB (II).
For more information … • Please visit www.PowerLogic.com
Appendix • User interface following in the next slides