PRVA PETOLETKA. Dobro došli!. INDUSTRIJSKA PNEUMATIKA A.D. SISTEM ATD U ELEKTROLIZI ALUMINIJUMA. 1889. PITSBURG. ATD AUTOMATSKO TAČKASTO DOZIRANJE. PODGORICA KOMBINAT ALUMINIJUMA. R CRNA GORA. ĆELIJA. OPREMA ATD. SILOS CENTRALNI SILOS SA ĆELIJSKI M DNEVNIM SILOSIMA
E N D
PRVA PETOLETKA Dobro došli! INDUSTRIJSKA PNEUMATIKA A.D.
SISTEM ATDU ELEKTROLIZI ALUMINIJUMA 1889. PITSBURG
ATD AUTOMATSKO TAČKASTO DOZIRANJE
PODGORICAKOMBINAT ALUMINIJUMA R CRNA GORA
OPREMA ATD • SILOS CENTRALNI SILOS SA ĆELIJSKIMDNEVNIM SILOSIMA - AUTOMATSKI TRANSPORT - POLUAUTOMATSKI • PROBIJAČ • DOZATOR • TEŽINA DOZIRANJA • peskovita glinica 1.1 do 2.2 kg / po TAČKI • sipkasta glinica ...0.6 do 0.8 Kg / po TAČK • BROJ TAČKI NAPAJANJA • peskovita glinica 1 TAČKA NA 50 do 100 kA • sipkasta glinica 1 TAČKA NA 30 do 50 kA • DOZATOR FLUORNIH SOLI
CIKLOGRAM RADACIKLOGRAM RADA JE REDOSLEDNOST RADA PROBIJAČA I DOZATORA, KAKO U JEDNOJ TAČKI NAPAJANJA, TAKO I U POGLEDU POTPUNE ELEKTROLIZE ( ĆELIJE ) SINHRONI D-PDoziranje glinice --- Vremenska pauza----Probijanje kore jedna doza t=…….secSINHRONI P-DProbijanje kore --- Vremenska pauza---- Doziranje glinicet min=…….sec jedna dozaASINHRONI Probijanje kore --- Vremenska pauza---- Doziranje glinicet min=…….sec n x doza
PNEUMATSKI SISTEMI TAČKASTOG DOZIRANJA • LAKO SE OSTVARUJU PROMENJLJIVA OPTEREĆENJA • RAVNOMERNO POVEĆANJE SILE PRI SAVLADAVANJU PREPREKA • NEMA BOJAZNI ZAGLAVLJIVANJA PROBOJCA • LAKO PODNOŠENJE TEMPERATURA DO 180 OC • PRODUŽEN VEK TRAJANJA • DOBAR RAD U MAGNETNIM POLJIMA
PPT PROJEKTUJEDVA SISTEMA • PNEUMO-ELEKTRIČNI SISTEMPPT-ATD 235-227000 • PNEUMATSKI SISTEM SA EKSTERNOM ELEKTRO KOMANDOMPPT-ATD 235-228000 SISTEMI ISPUNJAVAJU ZAHTEVE • POVIŠENA TEMPERATURA OKOLINE • ABRZIVNA OKOLINA ISPUNJENA GLINICOM • JAKO MAGNETNO POLJE
PPT ATD • UPRAVLJANJE CENTRALNIM RAČUNAROM • ĆELIJE SU LOKALNO OPREMLJENE PC ĆELIJSKIM MODULOM • PNEUMATSKA OPREMA JE MODULARNO DIZAJNIRANA NA ĆELIJI • LAKA ADAPTIBILNOST ZADATIM REŽIMIMA RADA
PNEUMO-ELEKTRIČNI SISTEMPPT-ATD 235-227000 BAZIRAN NA KONKRETNOM ZAHTEVU TEHNIČKIH SLUŽBI KAP-a. ĆELIJA SA DVA MESTA DOZIRANJA-PROBIJANJA I JEDNIM DOZATOROM FLUORNIH SOLI OPREMA • PC ĆELIJSI MODUL ............... 235-227100..............1 kom • PROBIJAČ.................................235-227200..............2 kom • DOZATOR GLINICE..................235-227300..............2 kom • DOZATOR FLUORNIH SOLI.....235-227400..............1 kom • LOKALNA PNEUMATSKA I ELEKTRIČNA VEZA NA ĆELIJI.........................................235-227050..............1 kom
PC ĆELIJSKI MODUL 235-227100 • MODUL JE SMEŠTEN U OKLOPLJENOJ KUTIJI • NAPAJANJE 24 V AC • ULAZNI KONEKTOR ZA POVEZIVANJE SA CENTRALNIM – EKSTERNIM PLC-om • ULAZNI KONEKTOR ZA LOKALNU KONTROLU RADA SVAKOG POJEDINAČNOG PNEUMATSKOG SISTEMA NA ĆELIJI • PANEL KUTIJE SADRŽI KONTROLNU SIGNALIZACIJU PC ĆELIJSKI MODUL SE INSTALIRA NA SPOLJNJOJ STRUKTURI ĆELIJE ŠTO OMOGUĆUJE LAKU DOSTUPNOST I KONTROLU RADA ĆELIJE
PROBIJAČ 235-227200 • STRUKTURA PROBIJAČA - PNEUMATSKI CILINDAR Ø 200 X 500 - PNEUMATSKI UPRAVLJAČKI BLOK-ELEKTRO KOMANDA - NOSEĆA STRUKTURA SA PROBOJCEM KORE - SENZOR KONTROLE PROBIJANJA KORE • NAPAJANJE PROBIJAČA - VAZDUH POD PRITISKOM 2 bar - VAZDUH POD PRITISKOM 6 bar - NAPON 24 V AC • DIELEKTRIČNO I TEMPERATURNO IZOLOVAN OD STRUKTURE ĆELIJE • U SLUČAJU PRESTANKA NAPAJANJA VAZDUHOM POD PRITISKOM , PROBIJAČ ZAUZIMA NULTI POLOŽAJ TJ. CILINDAR JE UVUČEN
PRINCIP RADA PROBIJAČA 1. RAD NA NISKOM PRITISKU • NORMALAN RAD PRITISKOM 2 bar • P=6 bar U TOKU KONTAKTA PROBOJCA I KADE 2. RAD NA PRITISKU 6 bar-a • P=6 bar U TOKU KONTAKTA PROBOJCA I KADE • ISKLJUČIVO U SUČAJU KADA JE SNAGA CILINDRA NEDOVOLJNA ZA PROBIJANJE KORE U SISTEM PROBIJAČA JE INTEGRISAN SENZORKADE KOJI OMOGUĆUJE DA CILINDAR PROBIJAČA PRAVI OPTIMALAN HOD ZA PROBIJANJE KORE
NULTI POLOŽAJ CILINDAR U NULTOM POLOŽAJU IMA PRITISK OD 2 bar-a
PROBIJANJE KORE NORMALAN RAD PRI PRITISKU 2 bar
VAĐENJE CILINDRA PRVIH 0.5 sec PRITISAK 6 bar – SIGURNO VAĐENJE
VAĐENJE CILINDRA NORMALAN RAD SA 2 bar PRITISKA
CILINDAR JE STAO NEMA SNAGU ZA PROBIJANJE KORE PO ISTICANJU VREMENA ZADRŽAVANJA P=6 bar
CILINDAR NEMA SNAGU ZA PROBIJANJE KORE • VRAĆA SE U NULTI POLOŽAJ • KREĆE SA 6 bar PRITISKA VAZDUHA • DALJI PROCES PO ZADATOJ VREMENSKOJ PETLJI
DOZATOR GLINICE 235-227300 STRUKTURA • PNEUMATSKI CILINDAR Ø 50 X 80 • PNEUMATSKI UPRAVLJAČKI BLOK- ELEKTRO KOMANDA • NOSEĆA STRUKTURA SA ZAPREMINSKIM DOZATOROM • KRAJNJI PREKIDAČI-KONTROLA DOZIRANJA NAPAJANJE DOZATORA • - VAZDUH POD PRITISKOM 6 bar • - NAPON 24 V AC U SLUČAJU PRESTANKA NAPAJANJA VAZDUHOM POD PRITISKOM , DOZATOR ZAUZIMA POLOŽAJ- DOZATOR ZATVOREN
DOZATOR FLUORNIH SOLI 235-227400 • STRUKTURA • PNEUMATSKI CILINDAR Ø 50 X 80 • PNEUMATSKI UPRAVLJAČKI BLOK- ELEKTRO KOMANDA • NOSEĆA STRUKTURA SA ZAPREMINSKIM DOZATOROM • KRAJNJI PREKIDAČI-KONTROLA DOZIRANJA NAPAJANJE DOZATORA • - VAZDUH POD PRITISKOM 6 bar • - NAPON 24 V AC U SLUČAJU PRESTANKA NAPAJANJA VAZDUHOM POD PRITISKOM , DOZATOR ZAUZIMA POLOŽAJ - DOZATOR ZATVOREN
ŠEMA DOZATORA GLINICE FLUORNIH SOLI
SISTEM ADT 235-227000 • INVESTICIONA UŠTEDA MANJA POTROŠNJA VAZDUHA • TEHNOLOŠKI PROCES PROBIJANJA I DOZIRANJA JE POTPUNO AUTONOMNO LOGIČKI ZAOKRUŽEN - GARANTUJE POTPUNUBEZBEDNOST PROCESA ELEKTROLIZE NIŽA INSTALISANA SNAGA KOMPRESORA UŠTEDA VAZDUHA POD PRITISKOM IMATE 500 CILINDARA Ø 200 x 500 PRITISAK NAPAJANJA P = 6 bar PROBIJANJE KORE NA 120 sek RADITE 365 DANA U GODINI CILINDAR PRAVI 262 800 CIKLUSA GODIŠNJE POTROŠNJA VAZDUHA P = 6bar Q = 56607 x 106 Nl P = 2bar Q = 24256 x 106 Nl
MINIMALNA KONTAMINACIJA ELEKTROLITA – VIŠI KVALITET ALUMINIJUMA • KONFORAN RAD RUKOVAOCA – SMANJENA ČUJNOST PNEUMATSKIH UREĐAJA
PNEUMATSKI SISTEM SA EKSTERNOM ELEKTRO KOMANDOMPPT-ATD 235-228000 • BAZIRAN NA KONKRETNOM ZAHTEVU TEHNIČKIH SLUŽBI KAP-a. • ĆELIJA SA DVA MESTA DOZIRANJA-PROBIJANJA I JEDNIM DOZATOROM FLUORNIH SOLI OPREMA • EKSTERNA EP KOMANDA ................ 235-228100..............1 kom • PROBIJAČ.............................................235-228200..............2 kom • DOZATOR GLINICE..............................235-228300..............2 kom • DOZATOR FLUORNIH SOLI.................235-228400..............1 kom • LOKALNA PNEUMATSKA I ELEKTRIČNA VEZA NA ĆELIJI.....................................................235-228050..............1 kom
EKSTRENA EP KOMANDA235-228100 • EKSTERNA EP KOMANDA JE SMEŠTENA U IZOLOVANOM ORMANU • NAPAJANJE 24 V AC • SADRŽI RAZVODNIKE KOJI UPRAVLJAJU PENUMATIKOM NA ĆELIJI EKSTERNA EP KOMANDA SE INSTALIRA NA SPOLJNJOJ STRUKTURI ĆELIJE ŠTO OMOGUĆUJE LAKU DOSTUPNOST I KONTROLU RADA ĆELIJE
PROBIJAČ 235-227200 • STRUKTURA PROBIJAČA PNEUMATSKI CILINDAR Ø 200 X 500 PNEUMATSKI UPRAVLJAČKI BLOK- PNEUMATSKA KOMANDA NOSEĆA STRUKTURA SA PROBOJCEM KORE • NAPAJANJE PROBIJAČA VAZDUH POD PRITISKOM 6 bar • DIELEKTRIČNO I TEMPERATURNO IZOLOVAN OD STRUKTURE ĆELIJE • U SLUČAJU PRESTANKA NAPAJANJA VAZDUHOM POD PRITISKOM , PROBIJAČ ZAUZIMA NULTI POLOŽAJ TJ. CILINDAR JE UVUČEN
PRINCIP RADA PROBIJAČA NULTI POLOŽAJ EKSTERNA EP KOMANDA PROBIJAČ
PROBIJANJE KORE CILINDAR IDE U KRAJNI POLOŽAJ AKTIVIRA RAZVODNIK U POKLOPCU CILINDRA RAZVODNIK ŠALJE PNEUMATSKU KOMANDU – CILINDAR SE UVLAČI
CILINDAR DVA PRIGUŠNNO-NEPOVRATNA VENTILA NA CILINDRU
CILINDAR JEDNIM PRIGUŠNO-NEPOVRATNIM VENTILOM NA CILINDRU
CILINDAR JEDAN PRIGUŠNO-NEPOVRATNI VENTIL I VENTIL BRZOG PRAŽNJENJA
DOZATOR GLINICE 235-228300 • STRUKTURA • PNEUMATSKI CILINDAR Ø 50 X 80 • PNEUMATSKI UPRAVLJAČKI BLOK • NOSEĆA STRUKTURA SA ZAPREMINSKIM DOZATOROM NAPAJANJE DOZATORA • - VAZDUH POD PRITISKOM 6 bar U SLUČAJU PRESTANKA NAPAJANJA VAZDUHOM POD PRITISKOM , DOZATOR ZAUZIMA POLOŽAJ DOZATOR - ZATVOREN
DOZATOR FLUORNIH SOLI 235-228300 • STRUKTURA • PNEUMATSKI CILINDAR Ø 50 X 80 • PNEUMATSKI UPRAVLJAČKI BLOK • NOSEĆA STRUKTURA SA ZAPREMINSKIM DOZATOROM NAPAJANJE DOZATORA VAZDUH POD PRITISKOM 6 bar U SLUČAJU PRESTANKA NAPAJANJA VAZDUHOM POD PRITISKOM , DOZATOR ZAUZIMA POLOŽAJ DOZATOR - ZATVOREN
ŠEMA DOZATORA GLINICE EKSTERNA EP KOMANDA FLUORNIH SOLI DOZATOR
MOGUĆNOSTI DOGRADNJE PNEUMATSKIH SISTEMA PROBIJAČ • KORIŠĆENJE CILINDARA RAZLIČITIH PREČNIKA I PRITISKA NAPAJANJA -- PREMA MOGUĆNOSTI NASTANKA KORE PRI RAZNIM TIPOVIMA GLINICE I TEHNOLOŠKIH PROCESA DOZATOR • KORIŠĆENJE CILINDARA SA PODEŠAVANJEM HODA • KORIŠĆENJE CILINDARA SA VIŠE HODOVA
INVESTICIJE 1/3 INVESTITOR CENA TROŠKOVI ODRŽAVANJE 2/3 EKSPLOATACIONI TROŠKOVI