270 likes | 560 Views
Amphibious Construction Battalion TWO. D. T. D. D etailed T roop D econtamination. Overview. Detailed Troop Decon (DTD) involves: Turn-in, Decon, and Reissue of troop gear Checking for and deconing troop MOPP gear Re-issuing of new MOPP gear as required
E N D
Amphibious Construction Battalion TWO D T D Detailed Troop Decontamination
Overview • Detailed Troop Decon (DTD) involves: • Turn-in, Decon, and Reissue of troop gear • Checking for and deconing troop MOPP gear • Re-issuing of new MOPP gear as required • As a member of the DTD, you will: • Monitor, identify, and handle contaminated items • Ensure the safety of troops being deconned • Re-issue MOPP gear and equipment to troops …all while in full MOPP gear for extended periods
Overview Decon Comes in 3 Levels: Immediate - Skin decon - Operator spray down Operational - Vehicle wash down - MOPP Gear exchange Thorough - Detailed troop and equipment decon (DTD, DED) - Reduce contaminants to a negligible risk
Gear & Equipment Joint Service Lightweight Integrated Suit Technology JSLIST - Good for 24 hours in a contaminated environment - 45 day life after opening the package - Can be laundered up to 6 times if not contaminated - Water resistant, but not waterproof - Old style gloves and boots still used with the JSLIST, will provide 24 hours of protection in a contaminated environment ...You will be required to operate decon stations in full MOPP Gear!
Gear & Equipment M291 & M295 Kits - Wallet like pouch with 6 decon packets - Black reactive and absorbent resin powder - Attached strap for inserting fingers - Applied by patting- not rubbing The M-295 is a larger version of the M-291 used for equipment decontamination...
M22 Detector Unit • M42 Remote Alarm • M28 Power Source Gear & Equipment M88 Chemical Agent Alarm System ...Used to detect chemical agents in the general area of the decontamination stations.
Gear & Equipment Improved Chemical Agent Monitor (ICAM) • Detects Nerve and Blister agent vapors • Wt: 4 lbs • Length: 15.5” • Operating Temp: -13 to 113 deg. F. ...Used to check for contamination on individuals being deconned.
Gear & Equipment …and some not so hi-tech gear
CONTAMINATION CONTROL LINE EQUIPMENT PATH EQUIPMENT PATH 1 OVERBOOT AND GLOVE DECON INDIVIDUAL GEAR DECON 7 4 3 2 MASK DECON POINT OVERBOOTS AND GLOVE REMOVAL OVERGARMENT REMOVAL OVERBOOT AND HOOD DECON ALTERNATE FOR RADIOLOGICAL DECON SOAPY WATER RINSE SPONGES TOWELS MASKPATH 5 6 MONITOR WIND DIRECTION MASK REMOVAL LIQUID CONTAMINATION CONTROL LINE 8 VAPOR CONTAMINATION CONTROL LINE REISSUE POINT Detailed Troop Decon
Station 1: Individual Gear Decon INDIVIDUAL GEAR DECON CONTAMINATION CONTROL LINE EQUIPMENT PATH EQUIPMENT PATH 1 WIND DIRECTION LIQUID CONTAMINATION CONTROL LINE VAPOR CONTAMINATION CONTROL LINE
Station 2: Boot & Hood Decon EQUIPMENT PATH OVERBOOT AND HOOD DECON 2 WIND DIRECTION LIQUID CONTAMINATION CONTROL LINE VAPOR CONTAMINATION CONTROL LINE
Station 3: Overgarment Removal EQUIPMENT PATH EQUIPMENT PATH OVERGARMENT REMOVAL 3 MASKPATH WIND DIRECTION LIQUID CONTAMINATION CONTROL LINE VAPOR CONTAMINATION CONTROL LINE
Station 4: Over Boot & Glove Removal EQUIPMENT PATH 4 OVERBOOT AND GLOVE DECON OVERBOOTS AND GLOVE REMOVAL WIND DIRECTION LIQUID CONTAMINATION CONTROL LINE VAPOR CONTAMINATION CONTROL LINE
Station 5: Monitor Station EQUIPMENT PATH MONITOR 5 WIND DIRECTION LIQUID CONTAMINATION CONTROL LINE VAPOR CONTAMINATION CONTROL LINE
Station 6: Mask Removal EQUIPMENT PATH 6 MASKPATH MASK REMOVAL WIND DIRECTION LIQUID CONTAMINATION CONTROL LINE VAPOR CONTAMINATION CONTROL LINE
Station 7: Mask Decon 7 MASK DECON POINT MASKPATH WIND DIRECTION LIQUID CONTAMINATION CONTROL LINE VAPOR CONTAMINATION CONTROL LINE
Station 8: Re-issue Point WIND DIRECTION LIQUID CONTAMINATION CONTROL LINE 8 REISSUE POINT VAPOR CONTAMINATION CONTROL LINE
Detailed Troop Decon Overview QUESTIONS?