1 / 28

TRUONG GIANG Electric Company

TRUONG GIANG Electric Company. TRUONG GIANG Electric JSC Date: 18th Sep 2009 Internal Meeting. Think future together. Nội dung. Giới thiệu Lĩnh vực hoạt động Kế hoạch & Chiến lược Sơ đồ tổ chức Doanh số. Giới thiệu.

graham
Download Presentation

TRUONG GIANG Electric Company

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TRUONG GIANG Electric Company TRUONG GIANG Electric JSC Date: 18th Sep 2009 Internal Meeting Think future together

  2. Nội dung • Giới thiệu • Lĩnh vực hoạt động • Kế hoạch & Chiến lược • Sơ đồ tổ chức • Doanh số

  3. Giới thiệu • Công ty Cổ Phần điện Trường Giang là Công ty thuộc Trường Giang Electric Family (tên gọi thân mật thay cho Truong Giang Electric group) • Tên tiếng Anh: Truong Giang Electric Joint Stock company • Tên viết tắt: Trường Giang Electric JSC • Giấy phép thành lập: 16/03/2009 (Sở KH&ĐT TP.HCM) • Đại diện pháp luật: Phạm Quốc Trường • Mã số thuế: 03 07 57 77 42 • Số tài khoản: 56 76 9999, Ngân hàng ACB • Vốn điều lệ ban đầu: • Website: www.tge.vn • Địa chỉ e-mail: info@tge.vn • Cổ đông sáng lập: 1 - Công ty TNHH Trường Giang, do ông Nguyễn Ngọc Thông làm đại diện, chủ tịch hội đồng quản trị 2 - Phạm Quốc Trường (Giám đốc) 3 - Nguyễn Ngọc Minh 4 - Đàm Văn Toàn 5 - Nguyễn Hoàng Mai 6 - Trầm Nguyên Thành

  4. Lĩnh vực hoạt động • Sản xuất: • - Sản xuất tủ bảng điện trung hạ thế • - Trạm Kiosk • - Các loại tủ điện hạ thế (MSB, SSB, DB, MCC, tủ tụ bù, ATS,…) • - Rack 19” • - Thang máng cáp • - OEMs • Thương mại: • - UPS, máy biến áp, hệ thống Busway, cáp,…

  5. Kế hoạch và chiến lược 2009 - 2011 • Nhiệm vụ: Sản xuất, kinh doanh hệ thống tủ bảng trung hạ thế Là OEMs cho các đối tác lớn • Chiến lược: Tập trung vào thị trường sản phẩm chất lượng • Đạt type Tested tủ MV năm 2009 • Đạt type Tested tủ LV năm 2010 • Dẫn đầu thị trường về thị trường tủ trung thế và trạm Kiosk • TOP 3 nhà sản xuất tủ bảng điện hạ thế • Xuất khẩu sản phẩm mang thương hiệu Trường Giang • Mở rộng quy mô hoạt động (tăng vốn điều lệ, lập chi nhánh - VPĐD, tạo điều kiện cho nhân viên tham gia cổ phần công ty,…) • Phát triển đa ngành nghề (lập các công ty trực thuộc Trường Giang Group): sau giai đoạn 1

  6. Hội Đồng Quản Trị (Board of President) Phạm Quốc Trường (General Director) Nguyễn Hoàng Mai (Technical & Production Manager) Vacant 1 (Administration & Account Manager) Nguyễn Ngọc Minh Purchase & Logistic Manager Đàm Văn Toàn (Sales & Marketing manager) Nguyễn Quang Doanh (Production Manager – Mechanical Division) Vacant 1 (General Accounting ) Vacant 1 (Marketer) M - Workers Vacant 2 (Estimator) Vacant 2 (Receptionist ) Hồ Văn Hòa (Production Manager – Electrical Division) E - Workers Vacant 3 (Projects Salesman) Vacant 3 (Security ) Vũ (R&D Manager– Mechanical Division) Vacant 4 (G.Service staff ) Vacant 1 (Electric technical Manager) Vacant 2 (QC) Sơ đồ tổ chức giai đoạn đầu

  7. TECHNICAL INFORMATION Technical specification & standard. 2.1 Technical specification Standard IEC 60439-1 Test Quatest Asta (australian) Electrical Characteristics Rated voltage (Ue) 690 V. AC Rated insulation voltage (Ui) 1000 V Dielectric test voltage 3 kV Rated impulse withstand voltage (Uimp) 12 kV Rated frequency 40-60 Hz Rated current (In) 250A - 7400A Rated short-time withstand current (Icw) Up to 100 kA 1 sec. Mechanical Characteristics Degree of protection, IEC 60529 IP 54 Framework steel (Aluzinc or painted) 2.0 mm Base frame steel (Painted) 2.5mm Doors & plates steel (Painted) 1.5 or 2.0 mm Mounting plates steel (Aluzinc) 1.5 mm Internal partitions steel (Aluzinc) 1.0-1.5 mm Internal separation Form 1 - 4 Stainless steel ANSI 304 , 316 With Aluzinc (mild steel coated with Aluminium and Zinc) DESIGN

  8. TECHNICAL INFORMATION Technical specification & standard. • 2.2 Paint specification • Paint Polyester powder paint • Coating thickness 60-80 µ • Colour (frames & cladding) RAL 7032 *, 7284, 7035 • Colour (base frame) RAL 9005 * • *(other colours on request) • PAINT PROCEDURE • All parts are transported on overhead conveyer through the following phases at a conveyer • speed of 3-4 m/minute. • Phase 1 Degreasing and iron phosphating at a temperature of 30° C • Phase 2 Degreasing and finishing iron phosphating at a temperature of 40° C • Phase 3 Shower with fresh tap water • Phase 4 Shower with demineralised water • Phase 5 Air drying with high pressure air blower • Phase 6 Heat drying in oven at a temperature of 120° C • Phase 7 Automatic electrostatic powder painting for standard colours or larger batches of • special colours. Manual electrostatic powder painting for smaller batches of special colours • Phase 8 Curing in oven for 10-12 minutes at a temperature of 170-200° C • Phase 9 Quality control of random samples as follows.: • Visual inspection against a master sample using 3 different shades of light. • Grid cut in order to test that the enamel adhesion exceeds • Control of coating thickness • Control of gloss

  9. Form • TECHNICAL INFORMATION • Enclosures • 3.1 Frame work • Every MSB is made exclusively from standard and type code- modules . All the modules embrace a high quality conforming to Truong Giang design specifications. The framebars and crossbars are supplied in sizes from 1 to 11 modules (1 module=200 mm). • Dimensions: Height: 1600, 1800, 2000, 2200, 2600mm (with busbar top unit). • Width: 400, 600, 800, 1000, 1200mm • Depth: 400, 600, 800,1000, 1200mm Internal Enclosure Busbar Functional units cable Separation including terminals for external conductors glands

  10. Form • 3.2 Internal form of separation • The following are typical forms of separation by partitions: • Form 1 No internal separation • Form 2a Separation of busbars from the functional units. • Terminals NOT separated from busbars.

  11. Form • Form 2b • Separation of busbars from the functional units. • Terminals separated from busbars. • Types 1 & 2 • Type 1: Busbar separation by insulated coverings • e.g sleeving, wrapping or coatings. • Type 2: Busbar separations by metallic or non • metallic rigid barriers or partitions • Form 3a • Separation of busbars from the functional units. • Separation of functional units from one another. • Separation of terminals from functional units but not from each other. • Terminals NOT separated from busbars

  12. Form • Form 3b • Separation of busbars from the functional units. • Types Separation of functional units from one another. • 1 & 2 Separation of terminals from functional units but not from each other. • Terminals separated from busbars. • Type 1: Busbar separation by insulated coverings • e.g sleeving, wrapping or coatings. • Type 2: Busbar separations by metallic or non • metallic rigid barriers or partitions. • Form 4a • Separation of busbars from the functional units. • Types Separation of functional units from one another. • 1 & 2 Separation of terminals of functional units • Terminals in same compartment as functional unit. • Type 1: Busbar separation by insulated coverings • e.g sleeving, wrapping or coatings. Cables glanded elsewhere. • Type 2: Busbar separations by metallic or non • metallic rigid barriers or partitions Cables glanded elsewhere.

  13. Form • Form 4b • Separation of busbars from the functional units. • Types Separation of functional units from one another. • 4,5 & 6 Separation of terminals of functional units • Terminals NOT in same compartment as functional • Type 4: Busbar separation by insulated coverings • e.g sleeving, wrapping or coatings. • Cables glanded elsewhere. • Type 5: Busbar separations by metallic or non • metallic rigid barriers or partitions.Terminals • separated by insulated coverings. • Cables glanded in common cabling chamber. • Type 6: All separation by metallic or non metallic • rigid barriers or partitions. • Cables glanded in common cabling chamber. • Form 4b Type 7: All separation by metallic or non metallic • Type 7 rigid barriers or partitions. • The terminals for each functional unit have • their own integral glanding facility.

  14. TECHNICAL INFORMATION Enclosures • 3.4 Rating table: RATING TABLE FOR COPPER BUSBARS ACCORDING TO DIN 43671 • Rating at 40°C ambient temperature and maximum busbar temperature 120°C. • The ratings are tested values and the tests are performed in a Form 4 type panel with a • degree of protection IP 4X

  15. TECHNICAL INFORMATION Enclosures • Main Busbar on top and cable connection front. • Busbar on top up to 4000A (One main busbar system)

  16. TECHNICAL INFORMATION Enclosures • Main Busbar on top and cable connection front. • Busbar on top from 4000A up to 7400A (Two main busbar systems)

  17. TECHNICAL INFORMATION Enclosures • Busbar on top up to 4000A (One main busbar system) • Busbar on top from 4000A up to 7400A (Two main busbar systems)

  18. TECHNICAL INFORMATION Enclosures • Busbar on Rear up to 4000A • Main busbar and section depths

  19. Assembly

  20. Assembly

  21. TECHNICAL INFORMATION4. Wiring • 4.1 Cable connection • In general, flexible copper cable is used for wiring the inside of a switchboard. For an operating voltage of less than half the cable insulating voltage or in other words < 500v , these cable are treated as belonging to lass 2. Consequently they may be secured directly to metal supports without inserting an insulator. • 4.2 Lug crimping • A lug should only contain a single power cable, all the strands of the conductor should be located inside the lug barrel. • Used crimp tools, of a suitable size , as recommended by the lug manufacture . Apply the tightening force specifited by the manufacture of the crimp too. Tools should be checked at regular intervals. • Hexagonal necking distributes the crimping in a uniform manner around the lug.

  22. Rountine test

  23. Rountine test

  24. TECHNICAL INFORMATION 6.Transport • 6.1 Lifting by crane • Maximum Load 200kg for 4 lifting Eyes • 6.2 Moving by pipe sections

  25. TECHNICAL INFORMATION7. Installation • 7.1 Distances to walls and gangway widths

  26. TECHNICAL INFORMATION7.2 Fixing plane • 7.2 Installation on false floor and directly on concrete • 1.Switchboard • 2. Boxgirder • 3. Fitted floor plate • 4. Support adjuistable • 5. Concrete floor