1 / 12

ESTUDIO COMPARATIVO DE RECTIFICADORES DE CORRIENTE

ESTUDIO COMPARATIVO DE RECTIFICADORES DE CORRIENTE. EFICIENCIA – RENDIMIENTO – CONSUMO – RIZADO – PESO –DIMENSIONES - SERVICIO. EFICIENCIA 100 %.

harken
Download Presentation

ESTUDIO COMPARATIVO DE RECTIFICADORES DE CORRIENTE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ESTUDIO COMPARATIVO DE RECTIFICADORES DE CORRIENTE EFICIENCIA – RENDIMIENTO – CONSUMO – RIZADO – PESO –DIMENSIONES - SERVICIO

  2. EFICIENCIA 100 % • TRABAJANDO A 10 VOLTIOS 1000 AMPERIOS DEBERIAMOS CONSUMIR 10.000 WATIOS ( VOLTIOS X AMPERIOS = WATIOS ) O LO QUE ES LO MISMO 10 KILOWATIOS. APLICANDO LA MEDIDA DE TIEMPO TENDREMOS EL VALOR CONSUMO / TIEMPO. EN EL CASO DE HORAS =10 KILOWATIOS / HORA.

  3. EFICIENCIA NORMAL ( 70 % ) • EL MISMO RECTIFICADOR CON UNA EFICIENCIA DEL 70 % CONSUMIRA 10 KILOWATIOS : 0.70 = 14.286 KILOWATIOS • UN QUASAR CUYA EFICIENCIA ES DEL 87 % CONSUMIRA 10 KILOWATIOS : 0.87 = 11.494 KILOWATIOS CONSIGUIENDO CON ELLO UN AHORRO ENERGETICO DEL 19.6 % RESPECTO AL ANTERIOR

  4. RIZADO-RIPPLE-CRESTAS • RECTIFICADOR MONOFASICO 48 % • RECTIFICADOR TRIFASICO EN Y 18 % • RECTIFICADOR TRIFASICO T.O. 5 % • RECTIFICADOR SWITCHING DC <3 % • RECTIFICADOR SWITCHING DCR <1 %

  5. COMPARATIVO DIMENSIONES • CAPACIDAD – AREA – ALTURA - PESO • 500 AMP. 0,278 1,066 181 • 2000 AMP. 0,395 1,778 687 • 5000 AMP. 0,697 2,057 1362 • SW 500 AMP. 0,209 0,175 25 • SW 2000 AMP. 0,224 0,897 135 • SW 5000 AMP. 0,224 1,950 265

  6. SISTEMAS DE REFRIGERACION • POR AIRE FORZADO : OBLIGA A UNA REVISION DE FILTROS CADA TRES MESES Y A SU SUSTITUCION UNA VEZ AL AÑO. • POR AGUA : NECESITA 100 LITROS HORA POR CADA 500 AMPERIOS A TEMPERATURA AMBIENTE ( 18 – 22 º C. )

  7. DIFERENTES EFICIENCIAS LEIDAS DE RECTIFICADORES DE DIFERENTES CLIENTES • 13.80 KW EFICIENCIA 75 % • 15.32 KW EFICIENCIA 65 % • 18.21 KW EFICIENCIA 55 % • 12.62 KW EFICIENCIA 79 % • 32.87 KW EFICIENCIA 30 % • 16.36 KW EFICIENCIA 61 % • 11.54 KW EFICIENCIA 88 %

  8. PROCESO PARA ESTUDIO • LECTURA DE SALIDA DEL EQUIPO ACTUAL EN CORRIENTE CONTINUA : VOLTIOS Y AMPERIOS • LECTURA DEL CONSUMO DE ENTRADA DEL EQUIPO ACTUAL EN CORRIENTE ALTERNA POR CADA UNA DE LAS TRES FASES • CALCULO DEL RENDIMIENTO DEL EQUIPO

  9. NEGOCIO EN VEZ DE INVERSION • DEMOSTRABLE CON REFERENCIAS • CASO 2 : LA INVERSION SE AMORTIZA EN 460 DIAS DE TRABAJO. 2,06 AÑOS. • CASO 6 : LA INVERSION SE AMORTIZA EN 361 DIAS DE TRABAJO. 1,62 AÑOS.

  10. NEGOCIO EN VEZ DE INVERSION • CASO 2: 15,32 KW/H – 11,49 KW/H = 3,83 • 3,83 X 24 X 223 = 20.498 KW/H • 20.498 X 0,1 = 2.049 € • 4.227 : 2.049 = 2,06 AÑOS • CASO 6: 16,36 KW/H – 11,49 KW/H = 4,87 • 4,87 X 24 X 223 = 26.064 KW/H • 26.064 X 0,1 = 2.606 € • 4.227 : 2.606 = 1,62 AÑOS

  11. NEGOCIO TOTAL

More Related