90 likes | 300 Views
EPREUVES D’ EFFORT INDICATIONS - PROTOCOLES. J.C . VERDIER INSTITUT CŒUR EFFORT SANTE PARIS. PROTOCOLES: Exemples. PROTOCOLES: Exemples. PROTOCOLES: PALIERS - RAMPE. PROTOCOLES: Exemples. PROTOCOLES: Exemples. I.C.: QUEL PROTOCOLE ?. Rampe ( R ): 30W / RAMPE 10W / min.
E N D
EPREUVES D’ EFFORTINDICATIONS - PROTOCOLES J.C. VERDIER INSTITUT CŒUR EFFORT SANTE PARIS
PROTOCOLES: Exemples PROTOCOLES: Exemples
I.C.: QUEL PROTOCOLE ? • Rampe ( R ): 30W / RAMPE 10W / min. • Paliers ( P ): 30 W / 10W / 1 min. • 22 sujets; étude randomisée. Rampe Paliers Pic VO2 ( l/min ): 1.5 (0.44 ) 1.49 (0.43 ) N. S. V.E. Max ( l/min ): 50.8 (12.9 ) 49.9 (14.5) N. S. F.C. Max 133 (24) 131 (22) P>0.05 W max. 110 (37.1) 105.6 (35.6) P>0.05 Durée ( min. ) 8.2 (2) 7.6 (1.9) P>0.05 REVILL SM; CHEST 2002
I.C.: QUEL PROTOCOLE ? • 15 I.C. F.E. 23.5% +/- 8.6 • 3 Protocoles : Bruce / Naughton modifié / Bicyclette • Résultats: • S. A .V. ( A.T. ) atteint par tous les patients BRUCE NAUGHTON CYCLE S.A.V. 15,4+/-4,1 15,6+/-4,4 11,8+/-3,0 PIC VO2 17,7+/-3,8 18,0+/-4,7 15,3+/-3,1 %VO2 Th. 57,20% 58,1+/-22,5 Strzelczyk and All. Am. Heart J. 2001 Sept; 142(3):384-7