410 likes | 424 Views
Beyond Standards Building Infection Prevention into the Building ’ s Infrastructure. Ottawa May 15, 16 , 2017. Teegor. Consulting Inc. Beyond Standards Building Infection Prevention into the Building ’ s Infrastructure. Roger Holliss Dir. of Engineering St. Mary’s General Hospital.
E N D
Beyond StandardsBuilding Infection Prevention into the Building’s Infrastructure Ottawa May 15, 16 , 2017
Teegor Consulting Inc. Beyond StandardsBuilding Infection Prevention into the Building’s Infrastructure Roger Holliss Dir. of Engineering St. Mary’s General Hospital Gordon Burrill President Teegor Consulting Inc. Ottawa May 15, 16 , 2017
Agenda • The magnitude of the HAI challenge • How standards happen • IC in the HCF standards world • Integrating IC into building infrastructure • Beyond standards • Q & A Ottawa May 15, 16 , 2017
Standards: A matter of perspective Ottawa May 15, 16 , 2017
Standards: A matter of perspective Ottawa May 15, 16 , 2017
Timeline of a standard Ottawa May 15, 16 , 2017
The Game Changer: CSA Z317.13-17 • Canadian Standards Association • CAN/CSA Z317.13-17: Infection control during construction, renovation and maintenance of health care facilities • Approved by the Technical Committee for Health Care Facilities Engineering and Physical Plant • Approval – January 03, 2017 • Printed – January 26, 2017 Ottawa May 15, 16 , 2017
Earlier Editions of this Standard • Canadian Standards Association • CAN/CSA Z317.13-03: • Released in May, 2003 • CAN/CSA Z317.13-07 • Released in Dec, 2007 • CAN/CSA Z317.13-12 • Released in Dec, 2012 • CAN/CSA Z317.13-17 • Released in January 26th, 2017 from Revolution to Evolution! Ottawa May 15, 16 , 2017
Changes in Z317.13-17 • Wall materials faced with water-impervious surfaces • Bathrooms/Kitchens/Unconditioned space • Near skylights • Bottom 1200 mm of exterior walls • Contractor training • Training requirements • Provisions for untrained workers • Management of rental CAHU’s • Written IC Plans for construction • “Construction clean” defined (sort of) Ottawa May 15, 16 , 2017
The Big One: CSA Z8000-11 • 1st Canadian national standard • Approved by TSC – July 13, 2011 • Approved by SCC – July 22, 2011 • Currently at Public Review • Anticipated next edition = 2018 Ottawa May 15, 16 , 2017
Proposals for CSA Z8000-18 • Hand hygiene sink locations • Class A healthcare facilities • Class B healthcare facilities • Prohibition of use of HHS as emergency eyewash stations • Use (or not) of forced air hand dryers • Evaluation for number of AIR’s • Laundry chutes & Large diameter p-tube for laundry/waste Ottawa May 15, 16 , 2017
The Unknown (kinda): CSA EXP06-2015 • Express Document • Released December 2015 • Available via COI Ottawa May 15, 16 , 2017
The Unknown (kinda): CSA EXP06-2015 • Check sheet oriented • Ask the right questions • Evaluation tool • Effectiveness • Applicability • Validity of claims Sample Ottawa May 15, 16 , 2017
IPAC & Engineering (background - standards) PIDAC Ottawa May 15, 16 , 2017
Standards Life Cycle Earliest pt. for CSA consideration Typical pt. when imbedded in a std. Ottawa May 15, 16 , 2017
Integrating IC into Bldg. Infras. (Relationship btn. Eng’g., IC & Housekeeping) Ottawa May 15, 16 , 2017
Integrating IC into Bldg. Infras. (Relationship btn. Eng’g., IC & Housekeeping) • Complementary vs. Replacement • Integrated vs. Independent, Ottawa May 15, 16 , 2017
Integrating IC into Building Infrastructure • Disinfection vs. Cleaning, Ottawa May 15, 16 , 2017
Integrating Infection Control into Building Infrastructure Ottawa May 15, 16 , 2017
UV Reflective On-site Coatings Quarternary Salts Residual Sprays Factory Coatings Temporary Coatings H2O2 / O3 H2O2 / Ag H2O2 TiO2 Silver Nano Probiotic Electrostatic Photocatalytic Emerging Technologies Ottawa May 15, 16 , 2017
Engineering Ozonated Water Housekeeping UVC’s Anti-Microbial Materials Chemical Mgt. TiO2 Paints Waste Ottawa May 15, 16 , 2017
Housekeeping Engineering UVC’s Ozonated H2O Chemical Mgt. Waste TiO2 Paint Anti-Microbial Materials ????? clinical Ottawa May 15, 16 , 2017
UVC Applications Ottawa May 15, 16 , 2017
UVC as Part ofInfrastructure • AHU Coil Cleaning: Ottawa May 15, 16 , 2017
UVC as Part ofInfrastructure Ottawa May 15, 16 , 2017
HVAC Coil UV Cleaners 6.8.6.1 Notes: 1) UV systems have been shown to be useful in reducing bio burden on cooling coils. They have also been demonstrated to reduce the number of active micro-organisms in ventilation air when installed in ductwork. Ottawa May 15, 16 , 2017
UVC as Part of Infrastructure 3 mo. after cleaning Ottawa May 15, 16 , 2017
UVC as Part of Infrastructure 3 months after cleaning Ottawa May 15, 16 , 2017
UVC as Part of Infrastructure 6 mo. after cleaning Ottawa May 15, 16 , 2017
6 months after cleaning Ottawa May 15, 16 , 2017
Ozonated Water Ottawa May 15, 16 , 2017
Anti- Microbial Materials Ottawa May 15, 16 , 2017
UV Reflective On-site Coatings Temporary Coatings Factory Coatings Residual Sprays Quarternary Salts Microbicidal Paints H2O2 / O3 H2O2 / Ag H2O2 TiO2 Electrostatic Silver Probiotic Nano Photocatalytic Emerging Technologies Ottawa May 15, 16 , 2017
UV Reflective On-site Coatings Quarternary Salts Residual Sprays Factory Coatings Temporary Coatings H2O2 / O3 H2O2 / Ag H2O2 TiO2 Silver Nano Probiotic Electrostatic Photocatalytic Emerging Technologies Microbicidal Paints Ottawa May 15, 16 , 2017
Don’t be the person that puts the “NO” in Innovation Ottawa May 15, 16 , 2017