TPC-RO DCS set-up

TPC-RO DCS set-up. PVSS main(s). PLC. PLC. HV. LV. COOLING. GAS. Th.Screen (??). Ethernet TCP/IP. Iseg OPC server. Wiener OPC server. Interface to FEE -temp.mon -I &V mon. Wago OPC server. Gas OPC(??) server. Profibus or Ethernet. CAN bus. Profibus or Ethernet. Outer chamber.

holt
Download Presentation

TPC-RO DCS set-up

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TPC-RO DCS set-up PVSS main(s) PLC PLC HV LV COOLING GAS Th.Screen (??) Ethernet TCP/IP Iseg OPC server Wiener OPC server Interface to FEE -temp.mon -I &V mon. Wago OPC server Gas OPC(??) server Profibus or Ethernet CAN bus Profibus or Ethernet Outer chamber FEC Front View of 1 Sector ??? HV Iseg crates (3) LV Wiener crates (22) 78 DAQ modules Inner chamber Schneider or Wago PLC Gas system(??) S.Popescu

  2. TPC Voltages DCS set-up PVSS main(s) HV LV Ethernet TCP/IP ECR optional optional Iseg OPC server(s) ?? Wiener OPC server(s) ?? 1 PCI-Can CRX CAN bus 18 nodes CAN bus 22 nodes • 22 LV PS crates (Wiener) • 5 modules/crate • 8 channels/module • Total: 880 channels 3HV PS crates (Iseg) 6 module/crate 16 channels/module Total: 288 channels PIT ~ 50 m ~ 50 m TPC detector TPC detector 1 PCI-Can S.Popescu

  3. PVSS main(s) TPC COOLING DCS set-up Solution 1 ECR PLC1 PLC2 Ethernet TCP/IP Wago or Schneider OPC server CRX Ethernet TCP/IP Schneider or Wago PLC Profibus ADC(s) for T sensors Rack ~50 m ~50 m 1 node UX 1 node Flow Pressure module I/O Heaters Face1 9 + 1 nodes Flow Pressure module I/O Heaters Face2 9 + 1 nodes 9 nodes 9 nodes S.Popescu

  4. PVSS main(s) TPC COOLING DCS set-up (Solution 2) ECR Ethernet TCP/IP OPC server Fieldbus card/driver (NI or Peak)… CRX Fieldbus CANopen ELMBs for T sensors ELMBs for T sensors Rack ~50 m ~50 m 1 node UX 1 node Flow Pressure module I/O Heaters Face1 Flow Pressure module I/O Heaters Face2 S.Popescu

  5. PVSS main(s) FEE DCS Monitor ECR Ethernet TCP/IP Ethernet TCP/IP FEE Control Application CRX Ethernet TCP/IP Or Profibus RCU RCU RCU RCU RCU RCU C6 : 20 FECs C5 : 20 FECs Outer chamber Parameters to be read/RCU: 25*(V1,V2,I1,I2, T) Error Register Parameters to be read/write: 25*(SW1, SW2) Total: ~ 45000 parameters C4 : 20 FECs FEC Front View of 1 Sector C3 : 18 FECs C2 : 25 FECs UX C1 : 18 FECs Inner chamber Control Link 6 RCU/sector Total: 216 RCU S.Popescu

  6. Side 2 Reservoir Rack1 Rack2 Circ.pump ST/CV ALICE DCS TPC S.Popescu

  7. Cooling Services from ST/CV ECR water water gas gas CRX TPC HMPID ITS SPD ITS SSD UX