1 / 14

11-Sep-14

Test results of straw rejection for 3 criteria - Dubna 806 straws: Load max F vs elongation dL data shape - test results of straw rejection for 3 criteria - conclusion Presented by S.Movchan. 11-Sep-14. S.Movchan Straw manufacturing and QC. 1. Dubna 806 straws

hubert
Download Presentation

11-Sep-14

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Test results of straw rejectionfor 3criteria • - Dubna 806 straws: Load max F vs elongation dLdata shape • - test results of straw rejectionfor 3criteria • - conclusion • Presented by S.Movchan 11-Sep-14 S.Movchan Straw manufacturing and QC 1

  2. Dubna 806 straws data taken from file “Straw_data_05_05.xls” 11-Sep-14 S.Movchan Straw manufacturing and QC 2

  3. Load max F vs elongation dL: 3-D presentation Dubna 806 straws N Cut: F=3.7 kG F (kG) dL(mm) 11-Sep-14 S.Movchan Straw manufacturing and QC 3 dL=1 mm

  4. Load max F vs elongation dL: 3-D presentation F (kG) N Good 3.7 kG Bad F (kG) dL(mm) dL(mm) 11-Sep-14 S.Movchan Straw manufacturing and QC 4

  5. Zoom of BAD region N 7 straws 8 straws N F (kG) dL(mm) F=(3.7-8) kG dL=(0-1) mm F (kG) dL(mm) 11-Sep-14 S.Movchan Straw manufacturing and QC 5

  6. Load max F vs elongation dL Blue – start straw Red – end straw data shape 11-Sep-14 S.Movchan Straw manufacturing and QC 6

  7. 6 samples from Sefar September Dubna data shape is not like expected: Due to this we have some probability to install “BAD”straw (elongation less than 1 mm) in the Module-0 after straw rejection (non elastic mylar deformation is started after dL=0.5 mm at 100 MPa) 11-Sep-14 S.Movchan Straw manufacturing and QC 7

  8. Dubna 806 straws • Test results of straw rejection for 3 criteria: • Load max F< 3.7 kG (Strength=100 MPa) • dL < 1 mm • dL < 1 mm @ Load max F< 3.7 kG 11-Sep-14 S.Movchan Straw manufacturing and QC 8

  9. Load max F<3.7 kG (Dubna 806 straws) Blue – start straw Red – end straw F=3.7 kG F min = 2.5 kG /10mm F max = 7.75 kG/10mm (K ~ 3, K=max/min) Rejected straws: N = 28 straws 11-Sep-14 S.Movchan Straw manufacturing and QC 9

  10. Load max F<3.7 kG(Dubna 806 straws) BUT Blue – start straw Red – end straw F=3.7 kG Rejected straws: N= 28 straws CERN straw rejection criteria: Load max L ≤ 3.7 kG (Strength ≤ 100 Mpa) Rejected straws: N = 28 straws (~ 3.5 %) and we have 7 straws (~ 1%)with elongation less than 1 mm 11-Sep-14 S.Movchan Straw manufacturing and QC 10 7 straws (~ 1% ) are with elongation less than 1 mm

  11. dL < 1 mm (Dubna 806 straws) Rejected straws: N= 15 straws Blue – start straw Red – end straw Dubna straw rejection criteria: elongation dL < 1 mm Rejected straws: N = 15 straws ( ~ 2 %) and all good straws have elongation more than dL ≥ 1 mm !!!!! dL=1 mm 11-Sep-14 S.Movchan Straw manufacturing and QC 11

  12. dL < 1 mm @ Load max < 3.7 kG (Dubna 806 straws) Blue – start straw Red – end straw dL=1 mm F=3.7 kG Rejected straws: N= 56 straws Dubna straw rejection criteria: elongation dL < 1 mm @ L < 3.7 kG Total rejected straws: N = 35 straws (~ 4 %) and all good straws have elongation more than dL ≥ 1 mm @ L > 3.7 kG 11-Sep-14 S.Movchan Straw manufacturing and QC 12

  13. Conclusion Both CERN and Dubna proposed criteria for straw rejection were tested on Dubna straws. Was shown that: - rejection criteria Load max F < 3.7 kG (Strength=100 Mpa)is wrong due to ~ 1 % of straws (7 straws out from 800) have elongation less than dL=1 mm - rejection criteria dL < 1 mm is correct. Number of rejected straws are N = 18 straws ( ~ 2 %) - combine criteria dL < 1 mm @ Load max F < 3.7 kG was tested too. Number of rejected straws are N = 35 straws ( ~ 4 %) 2 criteria and are tested and acceptable ------- Sefar straws: Straw sample elongation was not fixed during tensile test. So, straw rejection criteria can not be correctly tested. Elongation must be measure too. wrogn “soft” “hard” “soft” “hard” 11-Sep-14 S.Movchan Straw manufacturing and QC 13

  14. 11-Sep-14 S.Movchan Straw manufacturing and QC 14