1 / 27

Simbol-X INAF-PRIN KOM

Bologna, 16.03.2006. Simbol-X INAF-PRIN KOM. Thermal Blankets A. Collura. XACT facility at INAF-OAPA. Facility for the development, test and calibration of instrumentation for soft X-ray Astronomy.

jdempster
Download Presentation

Simbol-X INAF-PRIN KOM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Bologna, 16.03.2006 Simbol-X INAF-PRIN KOM Thermal Blankets A. Collura

  2. XACT facility at INAF-OAPA • Facility for the development, test and calibration of instrumentation for soft X-ray Astronomy. • Transmissivity, reflectivity, and quantum efficiency measurements in the soft X-ray band (0.1-20 keV) and UV. • Test and calibration in full imaging mode of moderate angular resolution (PSF > 10” FWHM), and small diameter (< 40 cm) grazing incidence X-ray optics. • Test and calibration of X-ray cryogenic detectors. [Collura et al. 1994(8), 1996(14); Barbera et al., 1994(7), Barbera et al. 2000(62)]

  3. X-Ray Beamline

  4. UV Beamline

  5. New Test Chamber and Beam-line

  6. 18 m 34.5 m The X-Ray Beam-Line Present configuration 100 63 55 40 50 35 25 30 25 30 20 Ø 20 50 100 100 100 100 100 L 100 200 200 200 200 200 100 New Configuration 200 80 100 80 80 80 80 63 63 55 50 40 30 30 35 20 25 25 Ø L 50 100 100 200 200 200 100 100 200 100 200 100 100 250 250 250 250 80 350

  7. Sources, Detectors and Monochromators ,SSD SSD = Solid State Detector

  8. Test Chamber and Clean Room

  9. Participation in the development and calibration of experiments for soft X-ray Astronomy • Chandra HRC: development and calibration of the UV/Ion shields, X-ray quantum efficiency of microchannel plates, end to end test; • Newton-XMM EPIC: development and calibration of the thin and medium filters, monitoring ageing effects of back-up filters; • JET-X CCD: development and calibration of the filters; • Solar-B XRT: development and calibration of the filters, reflectivity measurements of flat mirror samples.

  10. Chandra HRC: development of the UV/Ion shields • Investigation of different plastic materials • Simulation of the expected out of band rejection • Vibrational and acoustic tests • Baseline design • Calibration plan

  11. Chandra HRC: UV transmission measurements of the UV/Ion shields at the XACT facility Aluminum oxidation and interferences New filter design: Polyimide instead of Lexan, and single layer of aluminum (impact on Chandra ACIS, Newton-XMM EPIC, and JET-X).

  12. Chandra HRC: X-ray transmission measurements of the UV/Ion shields at the XACT facility • X-ray Source • Transmis. Grating Monoch. • GFPC + MCP detectors

  13. Chandra HRC: X-ray transmission measurements of the UV/Ion shields at Bessy Synchrotron • X-ray Transmission modeling • XANES and EXAFS

  14. Chandra HRC: Measurement of the UV/Visible refractive index of Polyimide • UV/Visible transmission measurements • of monolayer films • Parametric model of the extinction • coefficient K

  15. Newton-XMM EPIC: Filter development and calibration plan Newton-XMM EPIC: UV filter transmission measurements • Out of band rejection Newton-XMM EPIC: Synchrotron X-ray filter transmission measurements • X-ray Transmission modeling • XANES and EXAFS

  16. Newton-XMM EPIC: X-ray shadowgraphs of thin and medium filters at the XACT facility • GFPC+MCP detectors • Mosaic of 9 images

  17. Newton-XMM EPIC: Monitoring ageing effects of the thin and medium filters July 1997 July 2002 • Not modeled as an increase of aluminum oxidation • Possible explanations: Polyimide, Al surface roughness • No significant impact on the EPIC calibration

  18. JET-X CCD: Filter development and testing

  19. SOLAR-B XRT: Focal Plane Filter calibration • X_ray shadowgraphs • X-ray transmission measurements and modeling SOLAR-B XRT: Entrance Filters calibration • X-ray transmission measurements and modeling of • small filter samples SOLAR-B XRT: telescope calibration • Reflectivity measurements of flat mirror samples vs. • energy and angle of incidence. [Ongoing calibration program]

  20. Simbol-X: Coperte Termiche • Studio dei requirements termici (Alcatel Alenia) • Baseline design (ottico - meccanico) (OAPA+Luxel+Alcatel Alenia) • Misure su witness samples (OAPA) • Design finale (OAPA+Luxel+Alcatel Alenia) • Realizzazione (Alcatel Alenia + Luxel (?)) • Test meccanici (Alcatel Alenia) • Calibrazione (OAPA) • Protoni lenti (resistenza + stopping pwr) TBD

  21. Development of grazing incidence X-ray Optics • Plastic foils from common industrial applications • High surface smoothness by a combination of stretching • and rolling in higly polished rollers • Plastic is very light, elastic, cheap, has strong affinity to • coating • Plastic foils replicate the figure of the mandrel but not • the smoothness. Expensive superpolished mandrels not • required

  22. Shaping and coating the foils • Single and multilayer coating on large size foils before shaping • Vacuum hold-down mandrels to form cylindrical or conical shells [Schnopper et al.,1999(30)]

  23. Holding the foils • Foils hold inside grooves of the supporting wheels • Epoxy cured while foils are still inside the mandrel [Schnopper et al., 2001(42)]

  24. Full X-ray imaging tests at XACT [Barbera et al., 2001(64)]

  25. FWHM ~ 10” HPD ~ 2’ [Schnopper et al., 2002, Proc. SPIE 4851, in press]

  26. Detector Source Simbol-X: Un’idea per il test delle ottiche • Realizzazione di 2 ottiche identiche • Montaggio sullo stesso asse con i fuochi in direzioni opposte • Sorgente X puntiforme in un fuoco, rivelatore nell’altro fuoco • La PSF misurata è in prima approssimazione la somma in quadratura delle due PSF • Possibilità di migliorare ulteriormente l’informazione con scambi, rotazioni, masking

More Related