Modular Coil Cooling Option #5 – Three Cooling Tubes. FEA Model. Conductor cable: 75% copper 25% epoxy. Cooling tubes. Initial Temperature = 85K. Cooling tube inner diameter T = 80K. Copper clamp. Copper sheets. Clamp spacing = 10” Clamp plate width = 2.5”, thickness = 0.375”

Download Presentation

Clamp spacing = 10” Clamp plate width = 2.5”, thickness = 0.375”

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Modular Coil Cooling Option #5 – Three Cooling Tubes FEA Model Conductor cable: 75% copper 25% epoxy Cooling tubes Initial Temperature = 85K Cooling tube inner diameter T = 80K Copper clamp Copper sheets Clamp spacing = 10” Clamp plate width = 2.5”, thickness = 0.375” Thickness of conductor insulation = 0.03” Thickness of coil ground wrap = 0.03” Copper sheet thickness = 0.085” Cooling tube thickness = 0.02” Cooling tube OD = 0.406” Cooling tube (in web) OD = 0.50”

  2. Temperature Plots at The End of 1st Cooling Period -- Based on Kapton as Conductor Insulation Thermal conductivity of kapton 80 K 0.128 W/m-K 100 K 0.142 W/m-K 150 K 0.163 W/m-K 200 K 0.175 W/m-K

  3. Temperature Plots at The End of 1st Cooling Period -- If Thermal Conductivity of Insulation Increase 50% Thermal conductivity of Insulation 80 K 0.192 W/m-K 100 K 0.213 W/m-K 150 K 0.245 W/m-K 200 K 0.263 W/m-K

  4. Temperature Plots at The End of 1st Cooling Period -- Based on Kapton and CTD101K as Conductor Insulation -- Interior 20% Kapton, Exterior 10% Kapton Equivalent thermal conductivity: Le/Ke = L1/K1 + L2/K2 Thermal conductivity Kapton CTD-101K 80 K 0.128 W/m-K 0.260 W/m-K 100 K 0.142 W/m-K 0.290 W/m-K 150 K 0.163 W/m-K 0.343 W/m-K 200 K 0.175 W/m-K 0.375 W/m-K 10% Kapton 20% Kapton 80 K 0.236 W/m-K 0.216 W/m-K 100 K 0.263 W/m-K 0.240 W/m-K 150 K 0.309 W/m-K 0.281 W/m-K 200 K 0.337 W/m-K 0.305 W/m-K