綠色數據中心的節能科技 Energy Efficiency in Green Data Center. 蔡文蔭 博士. 再生能源暨 UPS 事業部 總經理. Dec 5 th , 2008 www.deltaww.com. Content. Green Data Center Data Center Power Consumption -- Power Supply Efficiency -- Power Distribution Efficiency Delta’s Proposal

josef
Download Presentation

Dec 5 th , 2008 deltaww

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 綠色數據中心的節能科技 Energy Efficiency in Green Data Center 蔡文蔭 博士 再生能源暨UPS事業部 總經理 Dec 5th, 2008 www.deltaww.com

  2. Content • Green Data Center • Data Center Power Consumption -- Power Supply Efficiency -- Power Distribution Efficiency • Delta’s Proposal 1. Green Data Center 2. HVDC UPS

  3. Data Center的主要設備組成 Source: 李魁鵬教授

  4. Source: 李魁鵬教授

  5. Data Center Energy Benchmarking Source:李魁鵬教授

  6. Power delivery efficiency to electronic loads only ~ 50% Fans UPS Power Distribution in Data Center Rack Server PSU VR BLDG PWR Electr. loads 480V AC 480V AC 208V AC PDU Server Electr. loads Total 285W – 405W 100W Server fans 13W VR 22W PSU 48W Room cooling 80W – 200W PDU 4W UPS 18W

  7. Data Center Power Consumption • Power Supply: Improving power supply efficiency • Power Distribution: Adapting new power delivery topology • Cooling: Optimizing thermal mapping management • IT Equipment: Hardware and software approach

  8. Power Supply Efficiency

  9. Power Supply Efficiency

  10. Power Supply Efficiency

  11. Power Supply Efficiency

  12. Distribution Efficiency Source: Intel, 2008 Jan

  13. Distribution Efficiency Source: Intel, 2007 July

  14. Distribution Efficiency Source: Intel, 2008 Jan

  15. Source: LBNL, 2006

  16. Distribution Efficiency Source: Intel, 2008 Jan

  17. 建築節能設計– LEED & EEWH DELSOLAR: LEED Delta Taipei Data Center Improvement Project Relative Humidity Temperature

  18. 綠色數據中心的節能科技 Energy Efficiency in Green Data Center 蔡文蔭 博士 再生能源暨UPS事業部 總經理 Dec 5th, 2008 www.deltaww.com