1 / 24

ECAL Studies for the CLIC_ILD detector

ECAL Studies for the CLIC_ILD detector. Jacopo Nardulli , CERN LCD. Why the ECAL is as it is ?. The LOI ILD Ecal structuring comes from an optimization from H. Videau available here ECAL Optimization from H. Videau

jovita
Download Presentation

ECAL Studies for the CLIC_ILD detector

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ECAL Studies for the CLIC_ILD detector Jacopo Nardulli, CERN LCD

  2. Why the ECAL is as it is ? • The LOI ILD Ecal structuring comes from an optimization from H. Videau available here ECAL Optimization from H. Videau • A few scenarios with different nr of layers and different absorber thickness are considered • Similar studies have also been done by M.S.Amjad and have been presented at the CALICE Meeting in Casablanca

  3. Goal of this study • Attempt a similar optimization on the CLIC version of the ILD detector • To have an ECAL with less layers, therefore cheaper, but without degradation of the performance • From our vol 2 CDR, cost chapter • You see ECAL contribution (~30% ?)

  4. Two possible studies • Fix the radiation length • But decrease the Nr of ECAL layers • Less expensive, energy resolution can be worse, as the pattern recognition • How to ? • Varying nr of layers and absorber thickness, • not the Si thickness • Vary the radiation length • And decrease the Nr of ECAL layers • Less expensive, overall performance changes • If I change the X0, can have more leakage into the HCAL • Varying nr of layers, absorber thickness and studying performance as a function of the X0

  5. Now only first study: Different ECAL models • Altering the number of layers and their absorber thickness in such a way that Total Absorber thickness in the detector remains the same. • The analyses in this talk are done with PandoraPFA with • Single Photon with θ and φ varying in the full range and Energies of 1, 10, 100 and 500 GeV and using • With Z  uds events of 91, 200, 500 and 1000 GeV • Default model 20 layers in 1st stack and 9 layers in 2nd stack

  6. Results for single photons

  7. Results: changing Nr of layers in 1st stack Mean Rec. Energy vs Input Energy [%] Energy Res. vs Input Energy

  8. Results: changing Nr of layers in 2nd stack [%] Energy Res. vs Input Energy

  9. Results: changing Nr of layers in 1st and 2nd stack [%] Energy Res. vs Input Energy • Preliminary conclusion: • Can go from 29 layers to 25 with hardly any loss in performance

  10. Results: just 1 stack [%] • Preliminary results • Using just 1 stack with less, but thicker, layers does not seem to degrade the energy resolution dramatically.

  11. Results for Z  uds events

  12. Results: changing Nr of layers in 1st stack

  13. Results: changing Nr of layers in 2nd stack

  14. Results: changing Nr of layers in 1st and 2nd stack Energy Res. vs Input Energy

  15. Results: just 1 stack

  16. Conclusions • First attempt of an optimization of the ECAL for CLIC_ILD • First results show that we can go from 29 to 25 layers with a small loss in performance • Using just 1 stack with less, but thicker, layers does not seem to degrade the energy resolution dramatically. • Results described in LCD-Open 2011-004 document, available here

  17. Next steps • Preliminary studies, lots of things not considered • i.e. is it right to use PFA ? Or should we use Garlic ? • Is the energy resolution the main/only parameter to be used to understand possible loss of performance caused by having less layers ? • Finish 1st study • More statistics • Use RMS90 • Move to the 2nd study • Performance as a function of the X0

  18. Backup

  19. Results: changing nr layers in 2nd stack Mean Rec. Energy vs Input Energy

  20. Only 1 layer

  21. Results: changing Nr of layers in 1st and 2nd stack Mean Rec. Energy vs Input Energy

  22. Disclaimer • Here showing the Energy Resolution vs. the Energy and using Single Gaussian fits • To get the energy resolution I am NOT using the official MarlinProcessor which calculates rms90 and mean90 • So do not look at absolute numbers, but at the general trend of the plots

  23. Results: changing Nr of layers in 1st and 2nd stack and different ratios • Reducing the X0 in 1st stack and changing the ratio does not seem to help. • Now try something else

  24. Thickness of layers

More Related