MTSC Training CourseDAC New Model & Function Prepared by: (Presenter's name) Date: (mm-dd-yyyy)
Agenda • New Model : ioPAC 8020 • New Functionality for ioLogik W5300 series • New Utility : DA-Center Confidential
Modular RTU Controller: ioPAC 8020 Confidential • ioPAC 8020 is designed for Harsh Environments • Robust Aluminum Housing • Impact – resistant • Prevent embrittlement • Wider Operation Temperature: -40 ~ 75ºC • Anti-Vibration • Daisy Chain Connection • Built-in 2 Switch Ports • Hot-Swappable I/O modules
ioPAC 8020 Outlook LED Indicators Serial Port .RS232 .RS422 .RS485 SD Card Slot .Not Available Now Two Switch Ports M12 or RJ45 Dual 24Vdc Power Inputs Confidential
ioPAC 8020 Specification • Hardware Spec. • Two Switch Ports – RJ45 or M12 • Dual Power Inputs – 12~36Vdc, 1.26A(max) • Certifications: UL508, EN50155 • Software Spec. • Management Utility: Modular-ioAdmin • Click&GoTM • SNMP V1/V2c/V3 • Watchdog – Modbus Connection/Unmatched I/O Modules
Non-stop Daisy Chain Support • Active linear bus topologies • Hardware pass-through function 100m 100m 100m 100m ioPAC 8020 ioPAC 8020 ioPAC 8020 ioPAC 8020 Master Controller Confidential
Active Alarm System • Solving the system problem immediately 192.168.19.20,2006/02/19,16:18:20,C=DI00,S=1 TCP/UDP 192.168.19.20 SNMP Trap Ethernet DI0 ‘eMail Internal:10ms Confidential
Hot Swappable I/O • Auto Detection of installed Modules • Enable/Disable I/O combination check Confidential
Product Line Information Confidential
Agenda • I/O Expansion • Virtual Channel • Cellular Connection • Meter/Sensor Operation Mode • New Conditions in Click&Go™ Confidential
Expandable up to 3 external E1200 Modules Ethernet Supported Models: E1210, E1211, E1212, E1214, E1240 ioLogik E1210 16DIs ioLogik E1214 6DIs, 6 Relays ioLogik W5340 4AIs, 12DIOs, 2 Relays ioLogik E1240 8AIs Confidential
E1200 as I/O Expansion • Make sure: • All the E1200s are on the same subnet as W5340. • All the E1200s settings are configured properly. • The E1200s system configuration files are exported already. • Add E1200 by importing the system configuration file: Confidential
E1200 as I/O Expansion • What if E1200 has been disconnected? You can reconnect by: Right-click and choose Reconnect Confidential
Virtual Channel • Work with “AI” and “Counter with Scaling” with multiple operation. Confidential
(RAW Counts) (T sec) Counter Scaling • The basic unit for operation = Counter Scaling • Change of a Certain Period with unit conversion (Counter Scaling) (T sec) Counter Scaling = M x △RAW + D i.e., Scaling multiply M: 100, D=0 T (sec) Confidential
Instantaneous (Current Value) Maximal Incremental Last – First sample = 900-0=900 Minimal Average (Summary / 10 samples = 590) Accumulation (Total Summary = 5900) Virtual Channel Operation Example • Counter Scaling update: 5 sec (10 samples), Virtual Channel Interval: 50 sec. per operation Counter Scaling T (sec) Confidential
Virtual Channel Application • Accumulation • Total volume of water in the last period of time (virtual channel interval) • Average • Average volume of water in the last period of time. • Min/Max • Min/Max level of water in the last period of time. • Incremental • Difference of water level in the last period of time. • Instantaneous • Current level of water Confidential
Optimization of Cellular Connection • Automatic Reconnection to network • Disabled by default to save bandwidth Carrier Check for physical connection PING Check for keeping connection Alive Confidential
Optimization of Cellular Connection • Network Log to system memory or SD • Disabled by default to protect the flash memory and save SD space • Helps to verify the communication problem during operation. Confidential
Meter/Sensor Confidential Two Operation Modes: 1. Transparent Serial Tunnel 2. Modbus TCP <-> Modbus RTU Gateway Transparent Serial Tunnel Mode - Support RS232/422/485 with built-in serial port. - Provides remote server address and port number to bring legacy serial devices to GPRS network. - For Serial Tunneling to work properly, Always On must be chosen under GPRS setting tab. Modbus TCP <-> Modbus RTU Gateway - Direct data exchange between host and field meter through Modbus.
New Condition in Click&Go Confidential Support I/O information of E1200 for IF condition. Support virtual channel as the trigger condition. New criteria for IF condition: - IF I/O Expansion Module Connection Fail THEN XXX.
Agenda Overview Setting Up DA-Center Confidential
Database SCADA Tag Access Data Conversion Data Conversion Moxa DACenter Moxa Active OPC Server Lite Active Tag Update Access Excel Bridging to SCADA/Database System Ethernet Update rate 250ms Tag Access Confidential
Customer Types • Large Scale Customers • Use huge number of I/O modules • Develop their own program and use database • Support ODBC driver (Oracle, MS-SQL, MySQL…) • Small Scale Customers • Use few I/O modules • Without SCADA software • Analyze data with Excel or Access database • Use Excel to generate trend chart Confidential
User Interface of MOXA DA-Center Configure Menu Tags Information MOXA Active OPC Server List Event Log Window
Setting up the DA-Center • 5 steps to get it DONE! • Create a new project. • Add a new dataset either to a file or database. • Choose the OPC server. • Map OPC tags to dataset. • Start Recording. Confidential
Setting up the DA-Center – (1) • Ensure the AOPC is installed/configured and activated. Confidential
Setting up the DA-Center – (2) Run DA-Center Add a dataset Confidential
Setting up the DA-Center – (3) Specify a name for your database Choose where you want to record your data Confidential
Setting up the DA-Center – (4) Choose or create a table Fields to display Confidential
Setting up the DA-Center – (5) Select an OPC server Confidential
Setting up the DA-Center – (6) Specify a group name Choose the update rate 100ms ~ 500ms Fields to display Choose the tags for your group Confidential
Setting up the DA-Center – (7) Map your tags to dataset Choose the tags you want to link to your dataset Confidential
Setting up the DA-Center – (8) Now it’s time to start recording The event log window showing the current status Confidential
Setting up the DA-Center – (9) Final result in Excel Confidential
Setting up the DA-Center – (10) Trend Chart: Line chart & Bar chart Confidential