Product Presentation 2008. Why Specify Actuators? Serious problems of the past. Actuators too often were treated like a commodity item with low first cost the #1 selection criteria Noise. Early Failure. Operational Problems. Recall.
E N D
Product Presentation 2008 F&S Actuator Presentation
Why Specify Actuators? Serious problems of the past. Actuators too often were treated like a commodity item with low first cost the #1 selection criteria Noise. Early Failure. Operational Problems. Recall. The actuator is an Integral part of the Fire Smoke System. F&S Actuator Presentation
Basic Features F&S Actuator Presentation
FSLF 80% of applications 4-6 sq.ft. 350F 15 sec F&S Actuator Presentation
FSNF Introduced 2002 Largest damper is a double section of 16.5 sq.ft at 250F Typically 12 sq.ft. 70 in-# minimum .23A draw at 120V 15 seconds F&S Actuator Presentation
133 in-lb at 250F <75 sec drive, <20 sec spring UL 11VA Run 6VA Hold Has manual override. Only 24VDC model made – battery and shipboard applications. FSAF F&S Actuator Presentation
Part Numbers Fire Smoke L = 30 in-lb N = 70 in-lb A = 133 in-lb 4 sq.ft 12 sq.ft. 12-18 sq.ft. Failsafe = spring 24, 120, 230 = Voltage F&S Actuator Presentation
-S models F&S Actuator Presentation
FSLF = SPST fixed FSAF (2-position) =SPST 10 degree fixed and a 25-85 degree adjustable switch. F&S Actuator Presentation
FSNF = SPDT fixed FSAF24-SR, -BAL SPDT switches 10 degree fixed and a 25-85 degree adjustable switch. F&S Actuator Presentation
Why specify Belimo? F&S Actuator Presentation
Quality: F&S Actuator Presentation
Micro Controller • Actuator cannot burn out if stalled before full rotation is achieved. • Motor runs cool for a long life span. • DC Motor: No noise when holding. • Very low Current Draw • The BEST - Not the cheapest way to control. 5-year Belimo Warranty F&S Actuator Presentation
Quality: Steel cold-weld clamp. Steel housing. F&S Actuator Presentation
Low Power Draw • FSLF • A 20 amp breaker implies 20 x • 75% / .15 = 100 actuators. • FSNF • A 20 amp breaker can take 20 x • 75% / .23 = 60 actuators. • Company X • 1.25 amp draw gives 15/1.25 = 12. • This is a significant wiring expense on larger projects. F&S Actuator Presentation
GO GREEN WITH ORANGE F&S Actuator Presentation
Belimo Quality ISO 9001 Quality Control FSLF is UL60730-1 which is going to replace UL873 F&S Actuator Presentation
Belimo Quality ISO Certified .1% failure rate over 2 years The only World Class actuators in the HVAC market. F&S Actuator Presentation
Belimo Quality 5-year Belimo Warranty The warranty is on the actuator; if it breaks, we will cover it to the owner or contractor regardless of damper OEM. Our cost to the manufacturers is within a few dollars of the competition. Price should not be the first issue. F&S Actuator Presentation
Recap FSLF 4 sq.ft. 350F 15 sec FSNF 12 sq.ft. 350F 15 sec FSAF 16 sq.ft. 250F 75/20 sec F&S Actuator Presentation
New Products FSAF24-SR Proportional 3-Position FSAF24-BAL F&S Actuator Presentation
FSAF24-SR Proportional F&S Actuator Presentation
FSAF24-BAL Shaft requires a fire & smoke damper and a balancing damper. The FSAF24-BAL allows cost and space savings. F&S Actuator Presentation
FSAF24-BAL F&S Actuator Presentation
FSAF24-BAL Fire Fighters Smoke Control System F&S Actuator Presentation
FSAF24-BAL F&S Actuator Presentation
Smoke Damper Actuators www.belimo.com F&S Actuator Presentation
Competitive Replacement Actuators Training informationInstallation Instructions F&S Actuator Presentation
Thank you AMERICAS F&S Actuator Presentation