CORRIENTE DE CORTOCIRCUITO

CORRIENTE DE CORTOCIRCUITO. EVALUACIÓN DE CORTOCIRCUITO. EL METODO DE COMPOSICIÓN. EL METODO CONVENCIONAL. EL METODO DE COMPOSICIÓN. Éste es el método que vamos a emplear en este ejemplo. INTENSIDAD DE CORTOCIRCUTITO SEGÚN EL TIPO Y POTENCIA APARENTE DEL TRANSFORMADOR. SUMERGIDOS. SECOS.

Download Presentation

CORRIENTE DE CORTOCIRCUITO

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CORRIENTE DE CORTOCIRCUITO Juan Ángel García Organero E31A

  2. EVALUACIÓN DE CORTOCIRCUITO. • EL METODO DE COMPOSICIÓN. • EL METODO CONVENCIONAL. • EL METODO DE COMPOSICIÓN. Éste es el método que vamos a emplear en este ejemplo Juan Ángel García Organero E31A

  3. INTENSIDAD DE CORTOCIRCUTITO SEGÚN EL TIPO Y POTENCIA APARENTE DEL TRANSFORMADOR • SUMERGIDOS. • SECOS. Transformador del ejemplo. A la instensidad de corto circuito se le multiplicara por 3 (Mas adelante se explica) Juan Ángel García Organero E31A

  4. TRANSFORMADORES CONECTADOS EN PARALELO. LAS CARACTERIS. DEL TRANSFO.. EJEMPLO INTERRUPTOR D1,D2 Y D3. EJEMPLO INTERRUPTOR D4. Juan Ángel García Organero E31A

  5. RESISTIVIDAD DE LOS CONDUCTORES Y REANTANCIA LINEAL. Juan Ángel García Organero E31A

  6. EJEMPLO: 45KA 1ª PARTE: -Icc ORIGEN: 45KA -CABLE DE COBRE: 300mm² -LONGITUD: 70m -Icc POSTERIOR: 23’8KA 2ª PARTE: -Icc ORIGEN: 23’8KA -CABLE DE COBRE: 16mm² -LONGITUD: 27m Icc PORTERIOR: 6’1KA ¿ DE DONDE SALE ESTE VALOR? 70m 23’8KA ¿ DE DONDE SALE ESTE VALOR? 22m CORTO 6’1KA ¿ DE DONDE SALE ESTE VALOR? Juan Ángel García Organero E31A

  7. GRACIASPOR SU ATENCIÓN Juan Ángel García Organero E31A

  8. CUADRO ECTRAPOLADO DE LA GUIA UTE C 15-105 CUADRO ECTRAPOLADO DE LA GUIA UTE C 15-105 70m 23’8KA Juan Ángel García Organero E31A

  9. CUADRO ECTRAPOLADO DE LA GUIA UTE C 15-105 27m 6’1KA Juan Ángel García Organero E31A

  10. INTENSIDAD DE CORTOCIRCUTITO SEGÚN EL TIPO Y POTENCIA APARENTE DEL TRANSFORMADOR COMO SON TRESTRANSFORMADORES IGUALES LA INTENSIDAD DE CORTOCIRCUITO SE MULTIPLICA POR 3: 15’17 x 3 = 45’51KA ----------- 45KA Juan Ángel García Organero E31A

  11. 3 TRANSFORMADORES. PARA QUE EL EJERCICIO SE PUEDA HACER TIENEN QUE TENER LAS SIGUIENTES CARACTERISTICAS. MISMO INDICE DE TRANSFORMACIÓN EN LAS BORNAS. MISMO INDICE HORARIO. MISMA TENSIÓN DE CORTOCIRCUITO INDICE DE POTENCIAS ASIGNADAS ENTRE 0’5 Y 2. QUE SOPORTEN EL MISMO CORTOCIRCUITO. QUE LA POTENCIA DEL TRANSFORMADORES ESTEN ENTRE EN NUESTRO CASO 630KVA+- 0’9 Y 2. MISMA TRANSFORMACION EN TODAS LAS SALIDAS DEL LOS TRANSFORMADORES. Juan Ángel García Organero E31A

  12. El poder de corte de D1 ha de ser igual o superior a la ICCT1, intensidad de cortocircuito a la salida del transformador correspondiente, en este caso T1. SE aplicaría el mismo criterio que en D1. Juan Ángel García Organero E31A

  13. El poder de corte de D4 ha de ser igual o superior a la suma de ICCT1, ICCT2 e ICCT3. Esta suma es la intensidad de cortocircuito a la entrada de D4 Juan Ángel García Organero E31A