330 likes | 498 Views
Lumical. R&D progress report. Ronen Ingbir. Lumical - A F uture L inear C ollider detector. HEP Tel Aviv University. Outline. Prague follow up. 1.Phi bias 2. Delta theta 3. Real life approach 4. New selection mechanism. Luminosity study Future steps. Dense design.
E N D
Lumical R&D progress report Ronen Ingbir Lumical - A Future Linear Collider detector HEP Tel Aviv University
Outline Prague follow up 1.Phi bias 2. Delta theta 3. Real life approach 4. New selection mechanism Luminosity study Future steps Dense design 1. Moliere radius 2. Radiation length 3. Detector properties 4. Design optimization 1. Margins design properties 2. Events close to margins 3. Maximum pick shower design 4. Remarks Design variations Lumical - A Future Linear Collider detector HEP Tel Aviv University
Fixed non zero bias under investigation. Azimuthal reconstruction Events Num. 250 GeV E weight. Log. weight. Constant value Constant value Lumical - A Future Linear Collider detector HEP Tel Aviv University
Two plots convinced us that the bias observed is not detector design dependent nor imperfect algorithm. Y (cm) 48 sectors design X (cm) Lumical - A Future Linear Collider detector HEP Tel Aviv University
Magnetic field Lumical - A Future Linear Collider detector HEP Tel Aviv University
Log. weight. E weight. Polar reconstruction 400 GeV Constant value Constant value Lumical - A Future Linear Collider detector HEP Tel Aviv University
Bias study ‘Pure’ electrons simulation Bhabha+Beam+BS(5e-4) Lumical - A Future Linear Collider detector HEP Tel Aviv University
Real life algorithm Working with both sides of the detector and looking at the difference between the reconstructed properties: (In real life we don’t have generated properties) Lumical - A Future Linear Collider detector HEP Tel Aviv University
Polar resolution Lumical - A Future Linear Collider detector HEP Tel Aviv University
Energy resolution Lumical - A Future Linear Collider detector HEP Tel Aviv University
33 mrad Events selection Energy Resolution The most significant event selection cut is the geometric acceptance cut. This cut was used to get the best energy, angular resolutions and minimum biases. Lumical - A Future Linear Collider detector HEP Tel Aviv University
Eout - Ein P= Eout + Ein New selection cut Out Signal Ring In Lumical - A Future Linear Collider detector HEP Tel Aviv University
Eout-Ein P= Eout+Ein Out In Lumical - A Future Linear Collider detector HEP Tel Aviv University
Eout-Ein P= Eout+Ein 3 cylinders 3 Rings 2 cylinders 3 Rings 1 cylinders 3 Rings Outline Lumical - A Future Linear Collider detector HEP Tel Aviv University
Dense design 15 cylinders * 24 sectors * 30 rings = 10800 cells 8 cm R L 6.1 m 28 cm 20 cm 20 cm 0.1 cm Silicon 0.55 cm Tungsten 0.31 cm Silicon 0.34 cm Tungsten Lumical - A Future Linear Collider detector HEP Tel Aviv University
Basic properties ? Lumical - A Future Linear Collider detector HEP Tel Aviv University
0.8cm 1.1cm Moliere radius Detector Signal X (cm) Lumical - A Future Linear Collider detector HEP Tel Aviv University
Radiation length Detector Signal Z (cm) 30 radiation length detector 47 radiation length detector Lumical - A Future Linear Collider detector HEP Tel Aviv University
Optimization Lumical - A Future Linear Collider detector HEP Tel Aviv University
Polar resolution & bias 16 cylinders 40 rings 15 cylinders 30 rings Lumical - A Future Linear Collider detector HEP Tel Aviv University
Energy resolution 16 cylinders 40 rings 15 cylinders 30 rings Lumical - A Future Linear Collider detector HEP Tel Aviv University
New geometric acceptance Events Energy Resolution Lumical - A Future Linear Collider detector HEP Tel Aviv University
Optimization Lumical - A Future Linear Collider detector HEP Tel Aviv University
Optimization Outline Lumical - A Future Linear Collider detector HEP Tel Aviv University
Margins around cells Having margins Means Losing Information Lumical - A Future Linear Collider detector HEP Tel Aviv University
One cylinder One sector Loosing information Detector signal Detector signal (deg) Radius (cm) Lumical - A Future Linear Collider detector HEP Tel Aviv University
Energy resolution Lumical - A Future Linear Collider detector HEP Tel Aviv University
Polar resolution Lumical - A Future Linear Collider detector HEP Tel Aviv University
4 rings 15 rings 11 rings 30 rings 15 cylinders 10 cylinders 20 cylinders 10cylinders 24 sectors * 15 rings * (10 cylinders + 20 cylinders) = 10,800 channels Maximum pick shower design Our basic detector is designed with 30 rings * 24 sectors * 15 cylinders = 10,800 channels Do we use these channels in the most effective way ? Lumical - A Future Linear Collider detector HEP Tel Aviv University
0.13e-3 rad 0.11e-3 rad Polar reconstruction Maximum pick shower design Basic Design Constant value Angular resolution improvement without changing the number of channels Other properties remain the same Constant value Lumical - A Future Linear Collider detector HEP Tel Aviv University
Remarks • Options to minimize the margin effect: • Rings rotation. • 2. Different cylinders segmentation Maximum pick shower design can enable us to reduce the number of channels while maintaining properties or to improve properties while kipping the same number of channels. Outline Lumical - A Future Linear Collider detector HEP Tel Aviv University
‘Real physics’ MC Bhabha + Beamstrahlung + Beamspread High statistics MC for required precision R&D status & future steps Pure electron MC Detector properties Events selection ‘Real physics’ MC + digitization noise + New max pick design + Margins Final optimization Lumical - A Future Linear Collider detector HEP Tel Aviv University
THE END Lumical - A Future Linear Collider detector HEP Tel Aviv University